Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Chemistry (12)
CHEMICAL MATERIAL >
nitrogen (3)
methane (1)
helium (1)
oxygen (1)
nitric oxide (1)
CHEMICAL ANALYTE
oxygen (12)
GEOGRAPHIC LOCATION
APMP (12)
Japan (12)
Result of the search
Your query 'Japan' produced 12 results New search

Japan, CERI (Chemicals Evaluation and Research Institute)
Complete CMCs in Chemistry for Gases for Japan (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen oxygen 9000 to 250000 0.6 9000 to 250000 0.6
Mechanism(s) for measurement service delivery: JCSS
Approved on 29 April 2005.
Internal NMI service identifier: CERI/3407a

Japan, NMIJ AIST (National Metrology Institute of Japan)
Complete CMCs in Chemistry for Gases for Japan (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
nitric oxide oxygen 11E-06 to 5000E-06 5 to 0.5
Mechanism(s) for measurement service delivery: NMIJ-CRM 3001
Internal NMI service identifier: NMIJ AIST/3001
This displays only one part of a multi-component CMC.

Japan, NMIJ AIST (National Metrology Institute of Japan)
Complete CMCs in Chemistry for Gases for Japan (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
sulfur dioxide oxygen 11E-06 to 5000E-06 5 to 0.5
Mechanism(s) for measurement service delivery: NMIJ-CRM 3002
Internal NMI service identifier: NMIJ AIST/3002
This displays only one part of a multi-component CMC.

Japan, NMIJ AIST (National Metrology Institute of Japan)
Complete CMCs in Chemistry for Gases for Japan (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
helium oxygen 11 to 15000 5 to 0.5
Mechanism(s) for measurement service delivery: Calibration
Uncertainty convention 2.
Approved on 24 January 2006.
Internal NMI service identifier: NMIJ AIST/340003

Japan, NMIJ AIST (National Metrology Institute of Japan)
Complete CMCs in Chemistry for Gases for Japan (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
methane oxygen 0.1 to 100 30 to 2 0.1 to 100 30 to 2
Mechanism(s) for measurement service delivery: NMIJ CRM 4051
Internal NMI service identifier: NMIJ AIST/340020
This displays only one part of a multi-component CMC.

Japan, NMIJ AIST (National Metrology Institute of Japan)
Complete CMCs in Chemistry for Gases for Japan (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
carbon dioxide oxygen 0.1 to 100 30 to 0.5 0.1 to 100 30 to 0.5
Mechanism(s) for measurement service delivery: NMIJ CRM 3407
Internal NMI service identifier: NMIJ AIST/340022
This displays only one part of a multi-component CMC.

Japan, NMIJ AIST (National Metrology Institute of Japan)
Complete CMCs in Chemistry for Gases for Japan (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in mmol/mol
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in mmol/mol
oxygen oxygen 0.99 to 1 1 to 0.0005 0.99 to 1 1 to 0.0005
Mechanism(s) for measurement service delivery: NMIJ CRM 3404
Uncertainty convention 2.
Approved on 15 December 2008.
Internal NMI service identifier: NMIJ AIST/340024
This displays only one part of a multi-component CMC.

Japan, NMIJ AIST (National Metrology Institute of Japan)
Complete CMCs in Chemistry for Gases for Japan (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
vinyl chloride oxygen 5 to 100 30 to 2 5 to 100 30 to 2
Mechanism(s) for measurement service delivery: NMIJ CRM 4041
Internal NMI service identifier: NMIJ AIST/340025
This displays only one part of a multi-component CMC.

Japan, NMIJ AIST (National Metrology Institute of Japan)
Complete CMCs in Chemistry for Gases for Japan (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
1,3-butadiene oxygen 5 to 1000 30 to 2 5 to 1000 30 to 2
Mechanism(s) for measurement service delivery: NMIJ CRM 4041
Internal NMI service identifier: NMIJ AIST/340026
This displays only one part of a multi-component CMC.

Japan, NMIJ AIST (National Metrology Institute of Japan)
Complete CMCs in Chemistry for Gases for Japan (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
nitrogen oxygen 11 to 100000 1.2 to 0.1
Mechanism(s) for measurement service delivery: Calibration
Uncertainty convention 2.
Approved on 12 March 2013.
Internal NMI service identifier: NMIJ AIST/34000

Japan, NMIJ AIST (National Metrology Institute of Japan)
Complete CMCs in Chemistry for Gases for Japan (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
propane oxygen 0.1 to 100 30 to 2 0.1 to 100 30 to 2
Mechanism(s) for measurement service delivery: NMIJ CRM 4052
Internal NMI service identifier: NMIJ AIST/340021
This displays only one part of a multi-component CMC.

Japan, NMIJ AIST (National Metrology Institute of Japan)
Complete CMCs in Chemistry for Gases for Japan (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in Ámol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in Ámol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
nitrogen oxygen 5 to 5000 1 to 0.1 5 to 5000 1 to 0.1
Mechanism(s) for measurement service delivery: NMIJ CRM 3408
Uncertainty convention 2.
Approved on 30 August 2017.
Internal NMI service identifier: NMIJ AIST/340002