Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Chemistry (20)
CHEMICAL MATERIAL
helium (20)
CHEMICAL ANALYTE >
nitrogen (5)
oxygen (3)
carbon monoxide (2)
carbon dioxide (2)
hydrogen (2)
GEOGRAPHIC LOCATION
APMP (20)
Korea, Republic of (20)
Result of the search
Your query 'kriss' produced 20 results New search

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
helium nitrogen 10E-06 to 1000E-06 5 to 1 10E-06 to 1000E-06 5 to 1
Mechanism(s) for measurement service delivery: CRM 112-01-1121N
Uncertainty convention 2.
Approved on 24 January 2006.
Internal NMI service identifier: KRISS/KG021

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
helium nitrogen 0.1E-02 to 50E-02 1 to 0.2 0.1E-02 to 50E-02 1 to 0.2
Mechanism(s) for measurement service delivery: CRM 112-01-1121P
Uncertainty convention 2.
Approved on 24 January 2006.
Internal NMI service identifier: KRISS/KG022

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
helium deuterium 1E-02 to 5E-02 1.5 1E-02 to 5E-02 1.5
Mechanism(s) for measurement service delivery: CRM 112-01-1822P
Approved on 24 January 2006.
Internal NMI service identifier: KRISS/KG045
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
helium oxygen 1E-02 to 5E-02 1.5 1E-02 to 5E-02 1.5
Mechanism(s) for measurement service delivery: CRM 112-01-1822P
Internal NMI service identifier: KRISS/KG045
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
helium nitrogen 3E-02 to 5E-02 1.5 3E-02 to 5E-02 1.5
Mechanism(s) for measurement service delivery: CRM 112-01-1822P
Internal NMI service identifier: KRISS/KG045
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
helium hydrogen 1E-06 to 100E-06 20 to 2
Mechanism(s) for measurement service delivery: Calibration
Uncertainty convention 2.
Approved on 24 January 2006.
Internal NMI service identifier: KRISS/KG134
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
helium nitrogen 0.1E-06 to 100E-06 30 to 2
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: KRISS/KG134
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
helium oxygen 0.1E-06 to 100E-06 30 to 2
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: KRISS/KG134
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
helium carbon monoxide 0.1E-06 to 100E-06 30 to 2
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: KRISS/KG134
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
helium carbon dioxide 0.1E-06 to 100E-06 30 to 2
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: KRISS/KG134
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
helium argon 1E-06 to 100E-06 30 to 2
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: KRISS/KG134
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
helium methane 0.1E-06 to 100E-06 30 to 2
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: KRISS/KG134
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
helium total hydrocarbon 0.1E-06 to 100E-06 30 to 2
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: KRISS/KG134
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
helium water 1E-06 to 100E-06 30 to 10
Mechanism(s) for measurement service delivery: Calibration
Internal NMI service identifier: KRISS/KG134
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
helium hydrogen 10E-06 to 1000E-06 5 to 1 10E-06 to 1000E-06 5 to 1
Mechanism(s) for measurement service delivery: CRM 112-01-1823N
Uncertainty convention 2.
Approved on 13 June 2013.
Internal NMI service identifier: KRISS/KG040
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
helium oxygen 10E-06 to 1000E-06 5 to 1 10E-06 to 1000E-06 5 to 1
Mechanism(s) for measurement service delivery: CRM 112-01-1823N
Internal NMI service identifier: KRISS/KG040
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
helium nitrogen 10E-06 to 1000E-06 5 to 1 10E-06 to 1000E-06 5 to 1
Mechanism(s) for measurement service delivery: CRM 112-01-1823N
Internal NMI service identifier: KRISS/KG040
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
helium methane 10E-06 to 1000E-06 3 to 0.5 10E-06 to 1000E-06 3 to 0.5
Mechanism(s) for measurement service delivery: CRM 112-01-1821N
Uncertainty convention 2.
Approved on 13 June 2013.
Internal NMI service identifier: KRISS/KG041
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
helium carbon monoxide 10E-06 to 1000E-06 3 to 0.5 10E-06 to 1000E-06 3 to 0.5
Mechanism(s) for measurement service delivery: CRM 112-01-1821N
Internal NMI service identifier: KRISS/KG041
This displays only one part of a multi-component CMC.

Korea, Republic of, KRISS (Korea Research Institute of Standards and Science)
Complete CMCs in Chemistry for Gases for Korea, Republic of (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Amount-of-substance fraction in mol/mol Relative expanded uncertainty
(k = 2, 95 %) in %
Amount-of-substance fraction in mol/mol Absolute expanded uncertainty
(k = 2, 95 %) in %
helium carbon dioxide 10E-06 to 1000E-06 3 to 0.5 10E-06 to 1000E-06 3 to 0.5
Mechanism(s) for measurement service delivery: CRM 112-01-1821N
Internal NMI service identifier: KRISS/KG041
This displays only one part of a multi-component CMC.