| Metrologia, 2009, 46(1), 47-61 |
| Critical review of information relevant to the correction of the effect of chemical impurities in gases used for the realization of ITS-90 fixed points |
| Pavese F. |
 |
Lipinski L., Kowal A., Szmyrka-Grzebyk A., Manuszkiewicz H., Steur P.P.M., Pavese F. The triple point of nitrogen
Metrologia, 2006, 43, n°5, 435-440
|
 |
Pavese F. On problems in the definition of the International Temperature Scale arising from the variability of the isotopic composition of some substances used for the fixed-points
Metrologia, 2005, 42, n°4, 194-200
|
 |
Fellmuth B., Wolber L., Hermier Y., Pavese F., Steur P.P.M., Peroni I., Szmyrka-Grzebyk A., Lipinski L., Tew W.L., Nakano T., Sakurai H., Tamura O., Head D., Hill K.D., Steele A.G. Isotopic and other influences on the realization of the triple point of hydrogen
Metrologia, 2005, 42, n°4, 171-193
|
 |
Hill K.D., Rudtsch S. Thermometry's dependence on chemical metrology: a needs-based assessment
Metrologia, 2005, 42, n°1, L1-L4
|
 |
Steele A.G., Fellmuth B., Head D.I., Hermier Y., Kang K.H., Steur P.P.M., Tew W.L. Key Comparison: CCT-K2: Key comparison of capsule-type standard platinum resistance thermometers from 13.8 K to 273.16 K
Metrologia, 2002, 39, n°6, 551-571
|
 |
Pavese F., Ancsin J., Astrov D.N., Bonhoure J., Bonnier G., Furukawa G.T., Kemp R.C., Maas H., Rusby R.L., Sakurai H., Ling Shan-Kang An International Intercomparison of Fixed Points by Means of Sealed Cells in the Range 13.81 K - 90.686 K
Metrologia, 1984, 20, n°4, 127-144
|
 |
Pavese F. The Triple Point of Argon and Oxygen
Metrologia, 1978, 14, n°3, 93-103
|
 |
Ancsin J. Vapour Pressures and Triple Point of Neon and the Influence of Impurities of These Properties
Metrologia, 1978, 14, n°1, 1-7
|
 |
Compton J.P., Ward S.D. Realization of the Boiling and Triple Points of Oxygen
Metrologia, 1976, 12, n°3, 101-113
|
 |
Ancsin J. Studies of Phase Changes in Argon
Metrologia, 1973, 9, n°4, 147-154
|
 |
Ancsin J. Dew Points, Boiling Points and Triple Points of "Pure" and Impure Oxygen
Metrologia, 1973, 9, n°1, 26-39
|
 |
Ancsin J. The Triple Point of Oxygen and its Change by Noble Gas Impurities
Metrologia, 1970, 6, n°2, 53-56
|
 |
Fellmuth B., Wolber L., Head D.I., Hermier Y., Hill K.D., Nakano T., Pavese F., Peruzzi A., Rusby R.L., Shkraba V., Steele A.G., Steur P.P.M., Szmyrka-Grzebyk A., Tew W.L., Wang L., White D.R. Investigation of low-temperature fixed points by an international star intercomparison of sealed triple-point cells
Metrologia, 2012, 49, n°3, 257-265
|
 |
Pavese F. Methods for the assessment of correction for chemical-impurity effects and related uncertainty in ITS-90 fixed points, namely of e-H2, Ne, O2 and Ar
Metrologia, 2011, 48, n°5, 268-274
|
 |
Pavese F., Steur P.P.M., Bancone N., Ferri D., Giraudi D. Comparison with U ≈ 50 ľK of neon samples of different isotopic compositions
Metrologia, 2010, 47, n°5, 499-517
|
|
|