Print this window Close this window
 
Metrologia, 2005, 42(4), 278-288
The triple point of xenon
Hill K.D., Steele A.G.

Full text available on-line: http://stacks.iop.org/met/42/278


References in Metrologia: 11 Citations in Metrologia: 2
References in Metrologia
Mangum B.W., Strouse G.F., Guthrie W.F., Pello R., Stock M., Renaot E., Hermier Y., Bonnier G., Marcarino P., Gam K.S., Kang K.H., Kim Y.-G., Nicholas J.V., White D.R., Dransfield T.D., Duan Y., Qu Y., Connolly J., Rusby R.L., Gray J., Sutton G.J.M, Head D.I., Hill K.D., Steele A., Nara K., Tegeler E., Noatsch U., Heyer D., Fellmuth B., Thiele-Krivoj B., Duris S., Pokhodun A.I., Moiseeva N.P., Ivanova A.G., de Groot M.J., Dubbeldam J.F.
Key Comparison: Summary of comparison of realizations of the ITS-90 over the range 83.8058 K to 933.473 K: CCT key comparison CCT-K3
Metrologia, 2002, 39, n°2, 179-205
Aregbe Y., Valkiers S., Mayer K., De Bièvre P., Wessel R.M., Alink A.
Measuring amount ratios of gas isotopes by two primary methods
Metrologia, 1998, 35, n°1, 7-16
Mangum B.W., Bloembergen P., Chattle M.V., Fellmuth B., Marcarino P., Pokhodun A.I.
Short Communication: On the International Temperature Scale of 1990 (ITS-90). Part I: Some definitions
Metrologia, 1997, 34, n°5, 427-429
Sutton C.M.
Accelerometer Calibration by Dynamic Position Measurement Using Heterodyne Laser Interferometry
Metrologia, 1990, 27, n°3, 133-138
Preston-Thomas H.
Erratum: The International Temperature Scale of 1990 (ITS-90)
Metrologia, 1990, 27, n°2, 107
Preston-Thomas H.
The International Temperature Scale of 1990 (ITS-90)
Metrologia, 1990, 27, n°1, 3-10
Ancsin J.
Triple Point of Xenon
Metrologia, 1988, 25, n°4, 221-225
Kemp R.C., Kemp W.R.G., Smart P.W.
The Triple Point of Xenon as a Possible Defining Point on an International Temperature Scale
Metrologia, 1985, 21, n°2, 43-48
Ancsin J.
Note Concerning the Suitability of Xenon as Temperature Fixed Point
Metrologia, 1978, 14, n°1, 45-46
Kirby C.G., Bedford R.E., Kathnelson J.
A Proposal for a New Deviation Function in the IPTS-68 below 273 K
Metrologia, 1975, 11, n°3, 117-124
Furukawa G.T.
Vapor Pressures of Natural Neon and of the Isotopes 20Ne and 22Ne from the Triple Point to the Normal Boiling Point
Metrologia, 1972, 8, n°1, 11-27
Citations in Metrologia
Meyer C.W., Tew W.L.
ITS-90 non-uniqueness from PRT subrange inconsistencies over the range 24.56 K to 273.16 K
Metrologia, 2006, 43, n°5, 341-352
Steele A.G.
ITS-90 Subrange inconsistency below the triple point of water
Metrologia, 2005, 42, n°4, 289-297