Metrologia, 2003, 40(2), 103-133
International report - Practical realization of the definition of the metre, including recommended radiations of other optical frequency standards (2001)
Quinn T.J.

Full text available on-line: http://stacks.iop.org/met/40/103


References in Metrologia: 21 Citations in Metrologia: 11
References in Metrologia
Shen S., Ni Y., Qian J. Liu Z., Shi C., An J., Wang L., Iwasaki S., Ishikawa J., Hong F.-L., Suh H.S., Labot J., Chartier A., Chartier J.-M.
International comparison: International comparisons of He-Ne lasers stabilized with 127I2 at lambda= 633 nm (July 1997). Part VIII: Comparison of NIM (China), NRLM (Japan), KRISS (Republic of Korea) and BIPM lasers at lambda= 633 nm
Metrologia, 2001, 38, n°2, 181-186
Viliesid M., Gutierrez-Munguia M., Galvan C.A., Castillo H.A., Madej A., Hall J.L., Stone J., Chartier A., Chartier J.-M.
International Comparison: International comparisons of He-Ne lasers stabilized with 127I2 at lambda= 633 nm. Part VII: Comparison of NORAMET 127I2-stabilized He-Ne lasers at lambda= 633 nm
Metrologia, 2000, 37, n°4, 317-322
Abramova L., Zakharenko Yu., Fedorine V., Blajev T., Kartaleva S., Karlsson H., Popescu GH., Chartier A., Chartier J.-M.
International comparisons of He-Ne lasers stabilized with 127I2 at lambda= 633 nm (July 1993 to September 1995). Part VI: Comparison of VNIIM (Russian Federation), NCM (Bulgaria), NMS (Norway), NILPRP (Romania) and BIPM lasers at lambda= 633 nm
Metrologia, 2000, 37, n°2, 115-120
Brown N., Jaatinen E., Suh H., Howick E., Xu G., Veldman I., Chartier A., Chartier J.-M.
International comparisons of He-Ne lasers stabilized with 127I2 at lambda= 633 nm (July 1993 to September 1995). Part V: Comparison of Asian-Pacific and South African lasers at lambda= 633 nm
Metrologia, 2000, 37, n°2, 107-113
Quinn T.J.
International Report: Practical realization of the definition of the metre (1997)
Metrologia, 1999, 36, n°3, 211-244
Darnedde H., Rowley W.R.C., Bertinetto F., Millerioux Y., Haitjema H., Wetzels S., Pirée H., Prieto E., Mar Pérez M., Vaucher B., Chartier A., Chartier J.-M.
International comparisons of He-Ne lasers stabilized with 127I2 at lambda= 633 nm (July 1993 to September 1995). Part IV: Comparison of Western European lasers at lambda= 633 nm
Metrologia, 1999, 36, n°3, 199-206
Edwards C.S., Barwood G.P., Gill P., Rowley W.R.C.
A 633 nm iodine-stabilized diode-laser frequency standard
Metrologia, 1999, 36, n°1, 41-45
Navratil V., Fodreková A., Gŕta R., Blabla J., Balling P., Ziegler M., Zeleny V., Petrű F., Lazar J., Veselá Z., Gliwa-Gliwinski J., Walczuk J., Bánréti E., Tomanyiczka K., Chartier A., Chartier J.-M.
International comparisons of He-Ne lasers stabilized with 127I2 at lambda= 633 nm (July 1993 to September 1995). Part III: Second comparison of Eastern European lasers at lambda= 633 nm
Metrologia, 1998, 35, n°6, 799-806
Bernard V., Nogues G., Daussy Ch., Constantin L., Chardonnet Ch.
CO2 laser stabilized on narrow saturated absorption resonances of CO2, improved absolute frequency measurements
Metrologia, 1997, 34, n°4, 313-318
Stahlberg B., Ikonen E., Haldin J., Hu J., Ahola T., Riski K., Pendrill L., Kärn U., Henningsen J., Simonsen H., Chartier A., Chartier J.-M.
International comparisons of He-Ne lasers stabilized with 127I2 at lambda = 633 nm (July 1993 to September 1995). Part II: Second comparison of Northern European lasers at lambda= 633 nm
Metrologia, 1997, 34, n°4, 301-307
Chartier J.-M., Chartier A.
International comparisons of He-Ne lasers stabilized with 127I2 at lambda= 633 nm (July 1993 to September 1995). Part I: General
Metrologia, 1997, 34, n°4, 297-300
Guinot B.
International Report: Application of general relativity to metrology
Metrologia, 1997, 34, n°3, 261-290
Simonsen H.R., Brand U., Riehle F.
International Comparison of Two Iodine-stabilized He-Ne Lasers at lambda= 543 nm
Metrologia, 1995, 31, n°5, 341-347
Razet A., Gagničre J., Juncar P.
Hyperfine Structure Analysis of the 33P(6-3) Line of 127I2 at 633 nm Using a Continuous-wave Tunable Dye Laser
Metrologia, 1993, 30, n°2, 61-65
Petru F., Popela B., Veselá Z.
Iodine-stabilized He-Ne Lasers at lambda= 633 nm of a Compact Construction
Metrologia, 1992, 29, n°4, 301-307
Razet A., Millerioux Y., Juncar P.
Hyperfine Structure of the 47R(9-2), 48P(11-3) and 48R(15-5) Lines of 127I2 at 612 nm as Secondary Standards of Optical Frequency
Metrologia, 1991, 28, n°4, 309-316
Clairon A., Dahmani B., Acef O., Granveaud M., Domnin Yu. S., Pouchkine S.B., Tatarenkov V.M., Felder R.
Recent Experiments Leading to the Characterization of the Performance of Portable (He-Ne)/CH4 Lasers. Part II: Results of the 1986 LPTF Absolute Frequency Measurements
Metrologia, 1988, 25, n°1, 9-16
Barwood G.P., Rowley W.R.C.
Characteristics of a 127I2-Stabilized Dye Laser at 576 nm
Metrologia, 1984, 20, n°1, 19-23
Documents Concerning the New Definition of the Metre
Metrologia, 1984, 19, n°4, 163-178
Blabla J., Smydke J., Chartier J.-M., Gläser M.
Comparison of the 127I2-Stabilized He-Ne Lasers at 633 nm Wavelength of the Czechoslovak Institute of Metrology and the Bureau International des Poids et Mesures
Metrologia, 1983, 19, n°2, 73-75
Magyar J.A., Brown N.
High Resolution Saturated Absorption Spectra of Iodine Molecules 129I2, 129I127I, and 127I2 at 633 nm
Metrologia, 1980, 16, n°2, 63-68
Citations in Metrologia
Pisani M., Yacoot A., Balling P., Bancone N., Birlikseven C., Çelik M., Flügge J., Hamid R., Köchert P., Kren P., Kuetgens U., Lassila A., Picotto G.B., Sahin E., Seppä J., Tedaldi M., Weichert C.
Comparison of the performance of the next generation of optical interferometers
Metrologia, 2012, 49, n°4, 455-467
Kuramoto N., Fujii K., Yamazawa K.
Volume measurements of 28Si spheres using an interferometer with a flat etalon to determine the Avogadro constant
Metrologia, 2011, 48, n°2, S83-S95
du Burck F., Tetchewo G., Goncharov A.N., Lopez O.
Narrow band noise rejection technique for laser frequency and length standards: application to frequency stabilization to I2 lines near dissociation limit at 501.7 nm
Metrologia, 2009, 46, n°5, 599-606
Stone J.A., Decker J.E., Gill P., Juncar P., A Lewis, Rovera G.D., Viliesid M.
Advice from the CCL on the use of unstabilized lasers as standards of wavelength: the helium-neon laser at 633 nm
Metrologia, 2009, 46, n°1, 11-18
Goncharov A., Lopez O., Amy-Klein A., Du Burck F.
Absolute frequency measurements for hyperfine structure determination of the R(26) 62-0 transition at 501.7 nm in molecular iodine
Metrologia, 2007, 44, n°5, 275-278
Wallerand J.-P., Robertsson L., Ma L.-S., Zucco M.
Absolute frequency measurement of molecular iodine lines at 514.7 nm, interrogated by a frequency-doubled Yb-doped fibre laser
Metrologia, 2006, 43, n°3, 294-298
Hamid R., Sahin E., Celik M., Özen G., Zucco M., Robertsson L., Ma L.-S.
10–12 level reproducibility of an iodine-stabilized He-Ne laser endorsed by absolute frequency measurements in the BIPM and UME
Metrologia, 2006, 43, n°1, 106-108
Edwards C.S., Barwood G.P., Margolis H.S., Gill P., Rowley W.R.C.
Development and absolute frequency measurement of a pair of 778 nm two-photon rubidium standards
Metrologia, 2005, 42, n°5, 464-467
Felder R.
Practical realization of the definition of the metre including recommended radiations of other optical frequency standards (2003)
Metrologia, 2005, 42, n°4, 323-325
Hollberg L., Diddams S., Bartels A., Fortier T., Kim K.
The Measurement of optical frequencies
Metrologia, 2005, 42, n°3, S105-S124
Madej A.A., Bernard J.E., Robertsson L., Ma L.-S., Zucco M., Windeler R.S.
Long Term Absolute Frequency Measurements of 633 nm Iodine Stabilized Laser Standards at NRC and Demonstration of High Reproducibility of such devices in International Frequency Measurements
Metrologia, 2004, 41, n°3, 152-160