Print this window Close this window
   
Metrologia, 1979, 15(4), 201-215
Determination of the Triple-Point Temperature of Gallium
Mangum B.W., Thornton D.D.

Full text available on-line: http://stacks.iop.org/met/15/201


References in Metrologia: 4 Citations in Metrologia: 10
References in Metrologia
Cox J.D., Vaughan M.F.
The Triple Point of Phenoxybenzene
Metrologia, 1980, 16, n°3, 105-109
Preston-Thomas H.
The International Practical Temperature Scale of 1968. Amended Edition of 1975
Metrologia, 1976, 12, n°1, 7-17
Barber C.R.
Foreword: The International Practical Temperature Scale of 1968 adopted by the Comité International des Poids et Mesures
Metrologia, 1969, 5, n°2, 35-44
Berry R.J.
Platinum Resistance Thermometry in the Range 630–900 °C
Metrologia, 1966, 2, n°2, 80-90
Citations in Metrologia
Mangum B.W., Strouse G.F., Guthrie W.F., Pello R., Stock M., Renaot E., Hermier Y., Bonnier G., Marcarino P., Gam K.S., Kang K.H., Kim Y.-G., Nicholas J.V., White D.R., Dransfield T.D., Duan Y., Qu Y., Connolly J., Rusby R.L., Gray J., Sutton G.J.M, Head D.I., Hill K.D., Steele A., Nara K., Tegeler E., Noatsch U., Heyer D., Fellmuth B., Thiele-Krivoj B., Duris S., Pokhodun A.I., Moiseeva N.P., Ivanova A.G., de Groot M.J., Dubbeldam J.F.
Key Comparison: Summary of comparison of realizations of the ITS-90 over the range 83.8058 K to 933.473 K: CCT key comparison CCT-K3
Metrologia, 2002, 39, n°2, 179-205
Mangum B.W., Bloembergen P., Chattle M.V., Fellmuth B., Marcarino P., Pokhodun A.I.
On the International Temperature Scale of 1990 (ITS-90). Part II: Recommended techniques for comparisons, at the highest level of accuracy, of fixed-point cells used for contact thermometry
Metrologia, 1999, 36, n°2, 79-88
Pello R., Goebel R., Köhler R.
Results of an international comparison of water triple-point cells
Metrologia, 1997, 34, n°5, 393-400
Mangum B.W., Pfeiffer E.R., Strouse G.F., Valencia-Rodriguez J., Lin J.H., Yeh T.I., Marcarino P., Dematteis R., Liu Y., Zhao Q., Ince A.T., Cakiroglu F., Nubbemeyer H.G., Jung H.-J.
Comparisons of some NIST fixed-point cells with similar cells of other standards laboratories
Metrologia, 1996, 33, n°3, 215-225
Bedford R.E., Bonnier G., Maas H., Pavese F.
Recommended values of temperature on the International Temperature Scale of 1990 for a selected set of secondary reference points
Metrologia, 1996, 33, n°2, 133-154
Mangum B.W.
Determination of the Indium Freezing-Point and Triple-Point Temperatures
Metrologia, 1989, 26, n°4, 211-217
Chattle M.V., Rusby R.L., Bonnier G., Moser A., Renaot E., Marcarino P., Bongiovanni G., Frassineti G., Neubert W., Fuhrmann H.G., Wessel I., Voorhof H.
An Intercomparison of Sealed Cells for Realizing the Melting and Triple Points of Gallium
Metrologia, 1986/1987, 23, n°3, 153-159
Bedford R.E., Bonnier G., Maas H., Pavese F.
Recommended Values of Temperature for a Selected Set of Secondary Reference Points
Metrologia, 1984, 20, n°4, 145-155
Bonhoure J., Pello R.
Température du Point Triple du Gallium
Metrologia, 1983, 19, n°1, 15-20
Connolly J.J., McAllan J.V.
Limitations on Metal Fixed Points Caused by Trace Impurities
Metrologia, 1980, 16, n°3, 127-132