Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (37)
PHYSICS
Impedance up to the MHz range
DC voltage, current, and resistance
Mass, mass standards (24)
Temperature (8)
AC voltage, current, and power (5)
GEOGRAPHIC LOCATION
SIM (37)
Costa Rica (37)
Result of the search
Your query 'Costa Rica' produced 37 results New search
1  2

 
Costa Rica, LACOMET (Laboratorio Costarricense de Metrologia)
Complete CMCs in Thermometry for Costa Rica (.PDF file)
Temperature. Long stem SPRT, -38.8344 °C
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mK: 0.49
Mercury triple point
Temperature: 20 °C ± 2 °C
Relative humidity: 55 % ± 10 %/rh
Approved on 17 January 2013
Internal NMI service identifier: LACOMET-02-1.3.2
 
Temperature. Long stem SPRT, 29.7646 ºC
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mK: 0.48
Gallium melting point
Sealed cell
Approved on 17 January 2013
Internal NMI service identifier: LACOMET-02-1.3.2
 
Temperature. Long stem SPRT, 156.5985 ºC
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mK: 1.5
Indium freezing point
Temperature: 20 °C ± 2 °C
Relative humidity: 55 % ± 15 %/rh
Approved on 17 January 2013
Internal NMI service identifier: LACOMET-02-1.3.2
 
Temperature. Long stem SPRT, 231.928 °C
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mK: 1.5
Tin freezing point
Temperature: 20 °C ± 2 °C
Relative humidity: 55 % ± 10 %/rh
Approved on 17 January 2013
Internal NMI service identifier: LACOMET-02-1.3.2
 
Temperature. Long stem SPRT, 419.527 °C
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mK: 1.9
Zinc freezing point
Temperature: 20 °C ± 2 °C
Relative humidity: 55 % ± 10 %/rh
Approved on 17 January 2013
Internal NMI service identifier: LACOMET-02-1.3.2
 
Temperature. Long stem SPRT, 660.323 °C
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mK: 4.6
Aluminum freezing point
Temperature: 20 °C ± 2 °C
Relative humidity: 55 % ± 10 %/rh
Approved on 17 January 2013
Internal NMI service identifier: LACOMET-02-1.3.2
 
Temperature. Thermistor, -20 °C to 50 °C
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mK: 8
Comparison stirred alcohol and water baths
Temperature: 20 °C ± 2 °C
Relative humidity: 55 % ± 10 %/rh
Approved on 17 January 2013
Internal NMI service identifier: LACOMET-02-2.2.3
 
Temperature. Thermocouple (Type E, J, K, N and T), -20 °C to 200 °C
Absolute expanded uncertainty (k = 2, level of confidence 95%) in °C: 0.8
Comparison stirred alcohol, water and oil baths
Temperature: 20 °C ± 2 °C
Relative humidity: 55 % ± 10 %/rh
Approved on 17 January 2013
Internal NMI service identifier: LACOMET-02-2.3.2
 
Costa Rica, ICE-LMVE (Instituto Costarricense de Electricidad, Laboratorio Metrológico de Variables Eléctricas)
Complete CMCs in Electricity and Magnetism for Costa Rica (.PDF file)
AC voltage (up to the MHz range), AC voltage up to 1100 V, sources. Multifunction calibrator, source, oscilloscope calibrator, 0.01 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 72 to 31213
Direct comparison
Frequency: 10 Hz to 500 kHz
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/52101
Uncertainty table
 
AC voltage (up to the MHz range), AC voltage up to 1100 V, meters. AC voltmeter, multimeter, multifunction calibrator, 0.01 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 50 to 10667
Direct comparison
Frequency: 10 Hz to 1 MHz
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/52201
Uncertainty table
 
AC current, AC current up to 100 A, sources. Multifunction calibrator, source, 0.0001 A to 10 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 392 to 8803
Direct comparison
Frequency: 10 Hz to 100 kHz
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/62101
Uncertainty table
 
AC current, AC current up to 100 A, meters. AC ammeter, multimeter, multifunction calibrator, 0.0001 A to 11 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 113 to 5849
Direct comparison
Frequency: 10 Hz to 10 kHz
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/62201
Uncertainty table
 
AC power, AC power and energy, single phase (frequencies below or equal to 400 Hz). Watthour meter, wattmeter, 15 W to 12000 W
Relative expanded uncertainty (k = 2, level of confidence 95%) in µW/VA: 289
Comparison
Frequency: 60 Hz
Applied voltage: 120 V and 240 V
Current: (0.25 A at 120 V and 0.3 A at 240 V) to 50 A
Power factor: 1, 0.5 lead, 0.5 lag
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/71101
 
Costa Rica, LACOMET (Laboratorio Costarricense de Metrologia)
Complete CMCs in Mass and related quantities for Costa Rica (.PDF file)
Conventional mass. Mass standards, 1 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.002
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 2 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.002
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 5 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.002
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 10 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.003
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 20 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.003
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 50 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.004
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01
 
Conventional mass. Mass standards, 100 mg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.005
Direct comparison
Temperature: 19 ºC to 21 ºC
Relative humidity: 45 % to 60 %
Approved on 26 November 2008
Internal NMI service identifier: LACOMET/MF-MA-PR-01