Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (14)
PHYSICS
AC voltage, current, and power
DC voltage, current, and resistance
Mass, mass standards
Temperature (8)
Impedance up to the MHz range (6)
GEOGRAPHIC LOCATION
SIM (14)
Costa Rica (14)
Result of the search
Your query 'Costa Rica' produced 14 results New search

 
Costa Rica, LACOMET (Laboratorio Costarricense de Metrologia)
Complete CMCs in Thermometry for Costa Rica (.PDF file)
Temperature. Long stem SPRT, -38.8344 °C
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mK: 0.49
Mercury triple point
Temperature: 20 °C ± 2 °C
Relative humidity: 55 % ± 10 %/rh
Approved on 17 January 2013
Internal NMI service identifier: LACOMET-02-1.3.2
 
Temperature. Long stem SPRT, 29.7646 ºC
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mK: 0.48
Gallium melting point
Sealed cell
Approved on 17 January 2013
Internal NMI service identifier: LACOMET-02-1.3.2
 
Temperature. Long stem SPRT, 156.5985 ºC
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mK: 1.5
Indium freezing point
Temperature: 20 °C ± 2 °C
Relative humidity: 55 % ± 15 %/rh
Approved on 17 January 2013
Internal NMI service identifier: LACOMET-02-1.3.2
 
Temperature. Long stem SPRT, 231.928 °C
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mK: 1.5
Tin freezing point
Temperature: 20 °C ± 2 °C
Relative humidity: 55 % ± 10 %/rh
Approved on 17 January 2013
Internal NMI service identifier: LACOMET-02-1.3.2
 
Temperature. Long stem SPRT, 419.527 °C
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mK: 1.9
Zinc freezing point
Temperature: 20 °C ± 2 °C
Relative humidity: 55 % ± 10 %/rh
Approved on 17 January 2013
Internal NMI service identifier: LACOMET-02-1.3.2
 
Temperature. Long stem SPRT, 660.323 °C
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mK: 4.6
Aluminum freezing point
Temperature: 20 °C ± 2 °C
Relative humidity: 55 % ± 10 %/rh
Approved on 17 January 2013
Internal NMI service identifier: LACOMET-02-1.3.2
 
Temperature. Thermistor, -20 °C to 50 °C
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mK: 8
Comparison stirred alcohol and water baths
Temperature: 20 °C ± 2 °C
Relative humidity: 55 % ± 10 %/rh
Approved on 17 January 2013
Internal NMI service identifier: LACOMET-02-2.2.3
 
Temperature. Thermocouple (Type E, J, K, N and T), -20 °C to 200 °C
Absolute expanded uncertainty (k = 2, level of confidence 95%) in °C: 0.8
Comparison stirred alcohol, water and oil baths
Temperature: 20 °C ± 2 °C
Relative humidity: 55 % ± 10 %/rh
Approved on 17 January 2013
Internal NMI service identifier: LACOMET-02-2.3.2
 
Costa Rica, ICE-LMVE (Instituto Costarricense de Electricidad, Laboratorio Metrológico de Variables Eléctricas)
Complete CMCs in Electricity and Magnetism for Costa Rica (.PDF file)
Impedance (up to the MHz range), capacitance, capacitance and dissipation factor for dielectric capacitors. Fixed capacitor, capacitance box, 10 pF
Relative expanded uncertainty (k = 2, level of confidence 95%) in F/F: 5.0E-04
Substitution
Frequency: 1000 Hz
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/42201
 
Impedance (up to the MHz range), capacitance, capacitance and dissipation factor for dielectric capacitors. Fixed capacitor, capacitance box, 100 pF
Relative expanded uncertainty (k = 2, level of confidence 95%) in F/F: 2.0E-04
Substitution
Frequency: 1000 Hz
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/42202
 
Impedance (up to the MHz range), capacitance, capacitance and dissipation factor for dielectric capacitors. Fixed capacitor, capacitance box, 1000 pF
Relative expanded uncertainty (k = 2, level of confidence 95%) in F/F: 7.5E-05
Substitution
Frequency: 1000 Hz
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/42203
 
Impedance (up to the MHz range), capacitance, meters. Capacitance meter, LCR meter, 10 pF
Relative expanded uncertainty (k = 2, level of confidence 95%) in F/F: 5.0E-04
Direct comparison
Frequency: 1000 Hz
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/42401
 
Impedance (up to the MHz range), capacitance, meters. Capacitance meter, LCR meter, 100 pF
Relative expanded uncertainty (k = 2, level of confidence 95%) in F/F: 2.0E-04
Direct comparison
Frequency: 1000 Hz
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/42402
 
Impedance (up to the MHz range), capacitance, meters. Capacitance meter, LCR meter, 1000 pF
Relative expanded uncertainty (k = 2, level of confidence 95%) in F/F: 7.5E-05
Direct comparison
Frequency: 1000 Hz
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/42403