| | | Mexico, CENAM (Centro Nacional de Metrologia) | |  | Complete CMCs in Mass and related quantities for Mexico (.PDF file)
|  | |
| Kinematic viscosity. Newtonian liquids, 0.003 mm2/s2 | | Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.22 | | Capillary viscometer | | Temperature: 20 °C | | Uncertainty statement corresponds to a reference temperature of 20 °C Approved on 22 June 2006 | | Internal NMI service identifier: CENAM/1 |
| | | Kinematic viscosity. Newtonian liquids, 0.1 mm2/s2 to 3 mm2/s2 | | Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.26 | | Capillary viscometer | | Temperature: 20 °C | | Uncertainty statement corresponds to a reference temperature of 20 °C Approved on 22 June 2006 | | Internal NMI service identifier: CENAM/2 |
| | | Kinematic viscosity. Newtonian liquids, 10 mm2/s2 to 30 mm2/s2 | | Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.36 | | Capillary viscometer | | Temperature: 20 °C | | Uncertainty statement corresponds to a reference temperature of 20 °C Approved on 22 June 2006 | | Internal NMI service identifier: CENAM/3 |
| | | Kinematic viscosity. Newtonian liquids, 0.9 mm2/s to 1.2 mm2/s | | Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.24 | | Reference liquid | | Temperature: 40 °C to 20 °C | | Uncertainty statement corresponds to a reference temperature of 20 °C Approved on 22 June 2006 | | Internal NMI service identifier: CENAM/4 |
| | | Kinematic viscosity. Newtonian liquids, 5 mm2/s to 22 mm2/s | | Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.30 | | Reference liquid | | Temperature: 40 °C to 20 °C | | Uncertainty statement corresponds to a reference temperature of 20 °C Approved on 22 June 2006 | | Internal NMI service identifier: CENAM/5 |
| | | Kinematic viscosity. Newtonian liquids, 3.5 mm2/s to 1800 mm2/s | | Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.35 | | Reference liquid | | Temperature: 100 °C to 20 °C | | Uncertainty statement corresponds to a reference temperature of 20 °C Approved on 22 June 2006 | | Internal NMI service identifier: CENAM/6 |
| | | Kinematic viscosity. Newtonian liquids, 80 mm2/s to 11600 mm2/s | | Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.40 | | Reference liquid | | Temperature: 100 °C to 20 ºC | | Uncertainty statement corresponds to a reference temperature of 20 °C Approved on 22 June 2006 | | Internal NMI service identifier: CENAM/7 |
| | | Kinematic viscosity. Newtonian liquids, 160 mm2/s to 35000 mm2/s | | Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.60 | | Reference liquid | | Temperature: 100 °C to 20 ºC | | Uncertainty statement corresponds to a reference temperature of 20 °C Approved on 22 June 2006 | | Internal NMI service identifier: CENAM/8 |
| | | Kinematic viscosity. Newtonian liquids, 200 mm2/s to 100000 mm2/s | | Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.70 | | Reference liquid | | Temperature: 100 °C to 20 ºC | | Uncertainty statement corresponds to a reference temperature of 20 °C Approved on 22 June 2006 | | Internal NMI service identifier: CENAM/9 |
| | | Kinematic viscosity. Newtonian liquids, 650 mm2/s to 326000 mm2/s | | Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.80 | | Reference liquid | | Temperature: 100 °C to 20 ºC | | Uncertainty statement corresponds to a reference temperature of 20 °C Approved on 22 June 2006 | | Internal NMI service identifier: CENAM/10 |
| | | Kinematic viscosity. Newtonian liquids, 3000 mm2/s to 770000 mm2/s | | Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.0 | | Reference liquid | | Temperature: 100 °C to 20 ºC | | Uncertainty statement corresponds to a reference temperature of 20 °C Approved on 22 June 2006 | | Internal NMI service identifier: CENAM/11 |
| | | Torque. Torque measurement instruments, 1 Nm to 10 Nm | | Relative expanded uncertainty (k = 2, level of confidence 95%): 0.0005 | | Direct comparison | | Temperature: (22 ± 1) °C | | Internal NMI service identifier: CENAM/720-H002a-001, 002,003 and 004 |
| | | Torque. Torque measurement instruments, 5 Nm to 50 Nm | | Relative expanded uncertainty (k = 2, level of confidence 95%): 0.0005 | | Direct comparison | | Temperature: (22 ± 1) °C | | Internal NMI service identifier: CENAM/720-H002a-001, 002,003 and 004 |
| | | Torque. Torque measurement instruments, 20 Nm to 200 Nm | | Relative expanded uncertainty (k = 2, level of confidence 95%): 0.0005 | | Direct comparison | | Temperature: (22 ± 1) °C | | Internal NMI service identifier: CENAM/720-H002a-001, 002,003 and 004 |
| | | Torque. Torque measurement instruments, 200 Nm to 2000 Nm | | Relative expanded uncertainty (k = 2, level of confidence 95%): 0.0005 | | Direct comparison | | Temperature: (22 ± 1) °C | | Internal NMI service identifier: CENAM/720-H002a-001, 002,003 and 004 |
|