Refine your search |
|
CMC AREA |
|
|
|
|
PHYSICS |
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
| | | Thailand, NIMT (National Institute of Metrology (Thailand)) | |  | Complete CMCs in Electricity and Magnetism for Thailand (.PDF file)
|  | |
| AC voltage up to 1000 V: sources. Multifunction calibrator, 300 mV to 700 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 23 | | AC-DC voltage transfer | | Voltage: 300 mV to 500 mV, 600 mV, 700 mV | | Frequency: 30 Hz to 300 Hz | | Internal NMI service identifier: NIMT/160 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 300 mV to 700 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 21 | | AC-DC voltage transfer | | Voltage: 300 mV to 500 mV, 600 mV, 700 mV | | Frequency: 400 Hz to 30 kHz | | Internal NMI service identifier: NIMT/161 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 300 mV to 700 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 21 | | AC-DC voltage transfer | | Voltage: 300 mV to 500 mV, 600 mV, 700 mV | | Frequency: 50 kHz to 70 kHz | | Internal NMI service identifier: NIMT/162 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 300 mV to 700 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 31 | | AC-DC voltage transfer | | Voltage: 300 mV to 500 mV, 600 mV, 700 mV | | Frequency: 100 kHz | | Internal NMI service identifier: NIMT/163 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 300 mV to 700 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 230 | | AC-DC voltage transfer | | Voltage: 300 mV to 500 mV, 600 mV, 700 mV | | Frequency: 200 kHz to 500 kHz | | Internal NMI service identifier: NIMT/164 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 300 mV to 700 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 230 | | AC-DC voltage transfer | | Voltage: 300 mV to 500 mV, 600 mV, 700 mV | | Frequency: 700 kHz to 1 MHz | | Internal NMI service identifier: NIMT/165 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 1 V to 7 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 20 | | AC-DC voltage transfer | | Voltage: 1 V, 2 V, 3 V, 4 V, 5 V, 6 V, 7 V | | Frequency: 10 Hz to 20 Hz | | Internal NMI service identifier: NIMT/166 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 1 V to 7 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 20 | | AC-DC voltage transfer | | Voltage: 1 V, 2 V, 3 V, 4 V, 5 V, 6 V, 7 V | | Frequency: 30 Hz to 300 Hz | | Internal NMI service identifier: NIMT/167 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 1 V to 7 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 20 | | AC-DC voltage transfer | | Voltage: 1 V, 2 V, 3 V, 4 V, 5 V, 6 V, 7 V | | Frequency: 400 Hz to 30 kHz | | Internal NMI service identifier: NIMT/168 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 1 V to 7 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 20 | | AC-DC voltage transfer | | Voltage: 1 V, 2 V, 3 V, 4 V, 5 V, 6 V, 7 V | | Frequency: 50 kHz to 70 kHz | | Internal NMI service identifier: NIMT/169 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 1 V to 7 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 29 | | AC-DC voltage transfer | | Voltage: 1 V, 2 V, 3 V, 4 V, 5 V, 6 V, 7 V | | Frequency: 100 kHz | | Internal NMI service identifier: NIMT/170 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 1 V to 7 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 180 | | AC-DC voltage transfer | | Voltage: 1 V, 2 V, 3 V, 4 V, 5 V, 6 V, 7 V | | Frequency: 200 kHz to 500 kHz | | Internal NMI service identifier: NIMT/171 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 1 V to 7 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 350 | | AC-DC voltage transfer | | Voltage: 1 V, 2 V, 3 V, 4 V, 5 V, 6 V, 7 V | | Frequency: 700 kHz to 1 MHz | | Internal NMI service identifier: NIMT/172 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 10 V to 30 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 29 | | AC-DC voltage transfer | | Voltage: 10 V, 20 V, 30 V | | Frequency: 10 Hz to 20 Hz | | Internal NMI service identifier: NIMT/173 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 10 V to 30 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 29 | | AC-DC voltage transfer | | Voltage: 10 V, 20 V, 30 V | | Frequency: 30 Hz to 300 Hz | | Internal NMI service identifier: NIMT/174 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 10 V to 30 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 23 | | AC-DC voltage transfer | | Voltage: 10 V, 20 V, 30 V | | Frequency: 400 Hz to 30 kHz | | Internal NMI service identifier: NIMT/175 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 10 V to 30 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 24 | | AC-DC voltage transfer | | Voltage: 10 V, 20 V, 30 V | | Frequency: 50 kHz to 70 kHz | | Internal NMI service identifier: NIMT/176 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 10 V to 30 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 24 | | AC-DC voltage transfer | | Voltage: 10 V, 20 V, 30 V | | Frequency: 100 kHz | | Internal NMI service identifier: NIMT/177 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 10 V to 30 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 230 | | AC-DC voltage transfer | | Voltage: 10 V, 20 V, 30 V | | Frequency: 200 kHz to 500 kHz | | Internal NMI service identifier: NIMT/178 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 10 V to 30 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 580 | | AC-DC voltage transfer | | Voltage: 10 V, 20 V, 30 V | | Frequency: 700 kHz to 1 MHz | | Internal NMI service identifier: NIMT/179 |
|