Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (8)
PHYSICS
Vibration
Fluid flow (8)
Mass gas flow rate (2)
Volume gas flow rate (2)
Volume hydrocarbon flow rate (2)
Mass water flow rate (1)
Volume water flow rate (1)
Volume of liquid
CHEMICAL ANALYTE
zinc
chromium
GEOGRAPHIC LOCATION
SIM (8)
Mexico (8)
Result of the search
Your query 'cenam' produced 8 results New search

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Mass and related quantities for Mexico (.PDF file)
Volume water flow rate. Liquid volume flow meters, 0.42 dm3/s to 200 dm3/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.040
Volumetric flowmeter (e.g., positive displacement, rotary piston, turbine, venturi, nozzle, ultrasonic, orifice plate, vortex meter, electromagnetic)
Fluid: water
Pressure: 0.1 MPa to 1 MPa
Temperature: 18 °C to 26 °C
Pipe sizes: 25 mm to 200 mm
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV1
 
Volume hydrocarbon flow rate. Oil flow meters, 0.00067 dm3/s to 1.67 dm3/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.060
Volumetric flowmeter (e.g., positive displacement, rotary piston, turbine, ultrasonic)
Kinematic viscosity: 0.5 mm2/s to 10 mm2/s
Pressure: 0.3 MPa to 0.6 MPa
Temperature: 18 °C to 24 °C
Pipe sizes: 6 mm to 25 mm
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV2
 
Volume hydrocarbon flow rate. Oil flow meters, 0.067 dm3/s to 94.5 dm3/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.080
Volumetric flowmeter (e.g., positive displacement, rotary piston, turbine, ultrasonic)
Kinematic viscosity: 0.5 mm2/s to 10 mm2/s
Pressure: 0.1 MPa to 4 MPa
Temperature: 0 °C to 82 °C
Pipe sizes: 50 mm to 200 mm
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV3
 
Volume gas flow rate. Gas flow meters, 0.00083 dm3/s to 0.5 dm3/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.15
Volumetric flowmeter (e.g., positive displacement, rotary piston, turbine, venturi, critical nozzle, laminar flow element, rotameter, differential pressure, wet gas meter, ultrasonic, orifice, vortex meter)
Fluid: dry air
Pressure: 0.1 MPa to 0.6 MPa
Temperature: 19 °C to 21 °C
Pipe sizes: 6 mm to 25 mm
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV4
 
Volume gas flow rate. Gas flow meters, 0.5 dm3/s to 30 dm3/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.25
Volumetric flowmeter (e.g., positive displacement, rotary piston, turbine, venturi, critical nozzle, laminar flow element, rotameter, differential pressure, wet gas meter, ultrasonic, orifice, vortex meter)
Fluid: dry air
Pressure: 0.1 MPa to 0.6 MPa
Temperature: 19 °C to 21 °C
Pipe sizes: 6 mm to 100 mm
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV5
 
Mass water flow rate. Liquid mass flow meters, 0.42 kg/s to 200 kg/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.032
Coriolis
Fluid: water
Pressure: 0.1 MPa to 1 MPa
Temperature: 18 °C to 26 °C
Pipe sizes: 25 mm to 200 mm
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV6
 
Mass gas flow rate. Gas flow meters, 0.001 g/s to 0.6 g/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.15
Critical flow nozzle, critical venturi, coriolis
Fluid: dry air
Pressure: 0.1 MPa to 0.6 MPa
Temperature: 19 °C to 21 °C
Pipe sizes: 6 mm to 25 mm
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV7
 
Mass gas flow rate. Gas flow meters, 0.6 g/s to 36 g/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.25
Critical flow nozzle, critical venturi, coriolis
Fluid: dry air
Pressure: 0.1 MPa to 0.6 MPa
Temperature: 19 °C to 21 °C
Pipe sizes: 6 mm to 100 mm
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV8