Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (1)
PHYSICS
Fluid flow
Torque, Viscosity, Hardness and Gravity
Impedance up to the MHz range (1)
Inductance: self inductance, high values (1)
CHEMICAL ANALYTE
lead
GEOGRAPHIC LOCATION
SIM (1)
Mexico (1)
Result of the search
Your query 'cenam' produced 1 result New search

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Electricity and Magnetism for Mexico (.PDF file)
Inductance: self inductance, high values. Fixed inductor, 10 H
Relative expanded uncertainty (k = 2, level of confidence 95%) in mH/H: 0.16
Substitution using an LCR meter
Frequency: 1 kHz
Current: 10 µA
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-010-06