Your query 'cenam' produced 14 results New search

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Organic solutions for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in ng/g Relative expanded uncertainty
(k = 2, 95%) in %
organic solution PCB 28 20 to 1000 6 to 10
Mechanism(s) for measurement service delivery: Analytical service
Uncertainty convention 1. Approved on 01 March 2005.
Internal NMI service identifier: CENAM/630-QS03.001

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Organic solutions for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in ng/g Relative expanded uncertainty
(k = 2, 95%) in %
organic solution PCB 101 20 to 1000 1 to 3
Mechanism(s) for measurement service delivery: Analytical service
Uncertainty convention 1. Approved on 01 March 2005.
Internal NMI service identifier: CENAM/630-QS03.002

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Organic solutions for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in ng/g Relative expanded uncertainty
(k = 2, 95%) in %
organic solution 4,4'-DDE 8 to 600 3 to 10
Mechanism(s) for measurement service delivery: Analytical services
Uncertainty convention 1. Approved on 01 March 2005.
Internal NMI service identifier: CENAM/630-Q021-010

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Organic solutions for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in ng/g Relative expanded uncertainty
(k = 2, 95%) in %
organic solution aldrin 10 to 600 3 to 1
Mechanism(s) for measurement service delivery: Analytical services, PT 630-IL-1203
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-Q021-002

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Organic solutions for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in ng/g Relative expanded uncertainty
(k = 2, 95%) in %
Mass fraction in µg/g Absolute expanded uncertainty
(k = 2, 95%) in µg/g
organic solution heptachlor epoxide 40 to 1500 3 to 1 24283 0.0275
Mechanism(s) for measurement service delivery: DMR 277a
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-Q021-003

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Organic solutions for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in ng/g Relative expanded uncertainty
(k = 2, 95%) in %
Mass fraction in µg/g Absolute expanded uncertainty
(k = 2, 95%) in µg/g
organic solution 4,4'-DDT 10 to 600 3 to 1 33269 0.0598
Mechanism(s) for measurement service delivery: DMR 277a
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-Q021-009

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Organic solutions for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in ng/g Relative expanded uncertainty
(k = 2, 95%) in %
organic solution PCB 105 90 to 1000 7 to 1
Mechanism(s) for measurement service delivery: Analytical service
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-QS03.003

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Organic solutions for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in ng/g Relative expanded uncertainty
(k = 2, 95%) in %
organic solution PCB 153 90 to 1000 4 to 1
Mechanism(s) for measurement service delivery: Analytical service
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-QS03.004

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Organic solutions for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in ng/g Relative expanded uncertainty
(k = 2, 95%) in %
organic solution PCB 170 90 to 1000 3 to 1
Mechanism(s) for measurement service delivery: Analytical service
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-QS03.005

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Organic solutions for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in µg/g Relative expanded uncertainty
(k = 2, 95%) in %
Mass fraction in µg/g Absolute expanded uncertainty
(k = 2, 95%) in µg/g
organic solution phenanthrene 3 to 15 3 to 1 8.06 to 103.1 0.16 to 1.9
Mechanism(s) for measurement service delivery: DMR-275a, DMR-276a
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-Q023-001

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Organic solutions for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in µg/g Relative expanded uncertainty
(k = 2, 95%) in %
Mass fraction in µg/g Absolute expanded uncertainty
(k = 2, 95%) in µg/g
organic solution fluoranthene 3 to 15 3 to 1 6.670 to 102.0 0.077 to 2.1
Mechanism(s) for measurement service delivery: DMR-275a, DMR-276a
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-Q023-002

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Organic solutions for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in µg/g Relative expanded uncertainty
(k = 2, 95%) in %
Mass fraction in µg/g Absolute expanded uncertainty
(k = 2, 95%) in µg/g
organic solution benzo(a)pyrene 3 to 15 3 to 1 6.270 to 97.1 0.079 to 1.2
Mechanism(s) for measurement service delivery: DMR-275a, DMR-276a
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-Q023-003

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Organic solutions for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in µg/g Relative expanded uncertainty
(k = 2, 95%) in %
Mass fraction in µg/g Absolute expanded uncertainty
(k = 2, 95%) in µg/g
organic solution benzo(ghi)perylene 3 to 15 3 to 1 12.34 to 66.1 0.18 to 1.4
Mechanism(s) for measurement service delivery: DMR-275a, DMR-276a
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-Q023-005

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Organic solutions for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in ng/g Relative expanded uncertainty
(k = 2, 95%) in %
Mass fraction in µg/g Absolute expanded uncertainty
(k = 2, 95%) in µg/g
organic solution lindane (gamma-BHC) (gamma-HCH) 12 to 900 3 to 1 3.1735 0.0410