Refine your search |
|
CMC AREA |
|
|
|
|
PHYSICS |
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
|
Your query 'Costa Rica' produced 24 results
|
New search
|
| | | Costa Rica, LACOMET (Laboratorio Costarricense de Metrologia) | |  | Complete CMCs in Mass and related quantities for Costa Rica (.PDF file)
|  | |
| Conventional mass. Mass standards, 1 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.002 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 2 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.002 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 5 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.002 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 10 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.003 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 20 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.003 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 50 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.004 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 100 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.005 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 200 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.007 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 500 mg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.008 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 1 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.010 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 2 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.013 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 5 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.017 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 10 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.020 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 20 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.027 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 50 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.033 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 100 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.053 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 200 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.10 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 500 g | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.27 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 1 kg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.53 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
| | | Conventional mass. Mass standards, 2 kg | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 1.5 | | Direct comparison | | Temperature: 19 ºC to 21 ºC | | Relative humidity: 45 % to 60 % | | Approved on 26 November 2008 | | Internal NMI service identifier: LACOMET/MF-MA-PR-01 |
|