Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (8)
PHYSICS
Sound in air (8)
Sound pressure level (5)
Mechanical impedance (1)
Air-conduction response level (1)
Bone-conduction response level (1)
Force response level
Sound pressure response level
Pressure sensitivity level
GEOGRAPHIC LOCATION
SIM (8)
Mexico (8)
Result of the search
Your query 'cenam' produced 8 results New search

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Acoustics, Ultrasound, Vibration for Mexico (.PDF file)
Sound pressure level. Pistonphone, single frequency 250 Hz, 70 dB (reference: 20 µPa) to 130 dB (reference: 20 µPa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.09
Calibrated measurement microphone
Microphone type: LS1P
Internal NMI service identifier: CENAM/510-F012-003
 
Sound pressure level. Pistonphone or sound calibrator, single frequency 125 Hz to 1 kHz, 70 dB (reference: 20 µPa) to 130 dB (reference: 20 µPa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.11
Calibrated measurement microphone
Microphone type: LS2P
Internal NMI service identifier: CENAM/510-F012-003
 
Sound pressure level. Sound calibrator, single frequency 125 to 1 kHz, 70 dB (reference: 20 µPa) to 130 dB (reference: 20 µPa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.16
Calibrated measurement microphone
Microphone type: WS2P
Internal NMI service identifier: CENAM/510-F015-003
 
Sound pressure level. Sound calibrator, multi-frequency, 70 dB (reference: 20 µPa) to 115 dB (reference: 20 µPa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.16
Calibrated measurement microphone
Frequency: 125 Hz to 1 kHz
Microphone type: LS2P
Internal NMI service identifier: CENAM/510-F012-008
 
Sound pressure level. Sound calibrator, multi-frequency, 70 dB (reference: 20 µPa) to 115 dB (reference: 20 µPa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.21
Calibrated measurement microphone
Frequency: 31.5 Hz to 8 kHz
Microphone type: LS2P
Internal NMI service identifier: CENAM/510-F012-008
 
Air-conduction response level. Audiometers. Measurand unit, dB HL (reference: threshold of hearing)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.38
IEC60645-1
Frequency: 125 Hz to 8 kHz
Internal NMI service identifier: CENAM/510-F016-001
 
Bone-conduction response level. Audiometers. Measurand unit, dB HL (reference: threshold of hearing)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.4
IEC60645-1
Frequency: 125 Hz to 4 kHz
Internal NMI service identifier: CENAM/510-F016-001
 
Mechanical impedance. Mechanical coupler system. Measurand unit, dB (reference: 1 N/(m/s) )
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.2
Comparison IEC 60373
Frequency: 125 Hz to 4 kHz
Internal NMI service identifier: CENAM/510-F012-011