Costa Rica, ICE-LMVE (Instituto Costarricense de Electricidad, Laboratorio Metrológico de Variables Eléctricas)
Complete CMCs in Electricity and Magnetism for Costa Rica (.PDF file)
DC voltage, DC voltage sources, intermediate values. DC voltage source, multifunction calibrator, > 10 V to 100 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 4.9 to 6.4
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/11301
 
DC voltage, DC voltage sources, intermediate values. DC voltage source, multifunction calibrator, 100 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 6.4 to 15.6
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/11302
 
DC voltage, DC voltage meters, intermediate values. DC voltmeter, multimeter, > 0.001 V to 0.01 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 3.8 to 416
Direct comparison
Approved on 21 April 2016
Internal NMI service identifier: ICE-LMVE/12201
Uncertainty table
 
DC voltage, DC voltage meters, intermediate values. DC voltmeter, multimeter, 0.01 V to 0.1 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 12 to 48
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/12202
 
DC voltage, DC voltage meters, intermediate values. DC voltmeter, multimeter, 0.1 V to 1 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 5.8 to 12
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/12203
 
DC voltage, DC voltage meters, intermediate values. DC voltmeter, multimeter, 1 V to 10 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 3.8 to 5.8
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/12204
 
DC voltage, DC voltage meters, intermediate values. DC voltmeter, multimeter, 10 V to 100 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 3.8 to 5.5
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/12205
 
DC voltage, DC voltage meters, intermediate values. DC voltmeter, multimeter, 100 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 5.5 to 7.0
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/12206
 
DC resistance, DC resistance standards and sources, low values. Fixed resistor, resistance box, 0.1 to 100 000 000
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 10 to 468
Direct comparison
Approved on 21 April 2016
Internal NMI service identifier: ICE-LMVE/21101
Uncertainty table
 
DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, > 1 to 10
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 18 to 53
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21201
 
DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, 10 to 100
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 16 to 50
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21202
 
DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, 100 to 1000
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 10 to 14
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21203
 
DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, 1 k to 10 k
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 10 to 14
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21204
 
DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, 10 k to 100 k
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 10 to 14
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21205
 
DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, 100 k to 1000 k
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 16 to 30
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21206
 
DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, > 1 M to 10 M
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 49 to 119
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21301
 
DC current, DC current meters, low values. Multimeter, 0.00001 A to 11 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 40 to 840
Direct comparison
Approved on 21 April 2016
Internal NMI service identifier: ICE-LMVE/32101
Uncertainty table
 
DC current, DC current meters, intermediate values. Multimeter, > 0.1 mA to 1 mA
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 43 to 107
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/32201
 
DC current, DC current meters, intermediate values. Multimeter, 1 mA to 10 mA
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 40 to 77
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/32202
 
DC current, DC current meters, intermediate values. Multimeter, 10 mA to 100 mA
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 53 to 117
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/32203