Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (10)
PHYSICS
Impedance up to the MHz range
DC voltage, current, and resistance
Sound in air (10)
Air-conduction response level (1)
Bone-conduction response level (1)
Force response level (1)
Mechanical impedance (1)
Sound pressure level (5)
Sound pressure response level (1)
Pressure sensitivity level
GEOGRAPHIC LOCATION
SIM (10)
Mexico (10)
Result of the search
Your query 'cenam' produced 10 results New search

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Acoustics, Ultrasound, Vibration for Mexico (.PDF file)
Sound pressure level. Pistonphone, single frequency 250 Hz, 70 dB (reference: 20 µPa) to 130 dB (reference: 20 µPa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.09
Calibrated measurement microphone
Microphone type: LS1P
Internal NMI service identifier: CENAM/510-F012-003
 
Sound pressure level. Pistonphone or sound calibrator, single frequency 125 Hz to 1 kHz, 70 dB (reference: 20 µPa) to 130 dB (reference: 20 µPa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.11
Calibrated measurement microphone
Microphone type: LS2P
Internal NMI service identifier: CENAM/510-F012-003
 
Sound pressure level. Sound calibrator, single frequency 125 to 1 kHz, 70 dB (reference: 20 µPa) to 130 dB (reference: 20 µPa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.16
Calibrated measurement microphone
Microphone type: WS2P
Internal NMI service identifier: CENAM/510-F015-003
 
Sound pressure level. Sound calibrator, multi-frequency, 70 dB (reference: 20 µPa) to 115 dB (reference: 20 µPa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.16
Calibrated measurement microphone
Frequency: 125 Hz to 1 kHz
Microphone type: LS2P
Internal NMI service identifier: CENAM/510-F012-008
 
Sound pressure level. Sound calibrator, multi-frequency, 70 dB (reference: 20 µPa) to 115 dB (reference: 20 µPa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.21
Calibrated measurement microphone
Frequency: 31.5 Hz to 8 kHz
Microphone type: LS2P
Internal NMI service identifier: CENAM/510-F012-008
 
Sound pressure response level. Sound level meters. Measurand unit, dB (reference: 20 µPa)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.3
Comparison IEC651 and IEC804
Frequency: 250 Hz to 1 kHz
Internal NMI service identifier: CENAM/510-F015-001
 
Air-conduction response level. Audiometers. Measurand unit, dB HL (reference: threshold of hearing)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.38
IEC60645-1
Frequency: 125 Hz to 8 kHz
Internal NMI service identifier: CENAM/510-F016-001
 
Bone-conduction response level. Audiometers. Measurand unit, dB HL (reference: threshold of hearing)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.4
IEC60645-1
Frequency: 125 Hz to 4 kHz
Internal NMI service identifier: CENAM/510-F016-001
 
Force response level. Mechanical coupler system. Measurand unit, dB (reference: reference equivalent threshold force)
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.3
Comparison IEC 60373
Frequency: 125 Hz to 4 kHz
Internal NMI service identifier: CENAM/510-F012-011
 
Mechanical impedance. Mechanical coupler system. Measurand unit, dB (reference: 1 N/(m/s) )
Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB: 0.2
Comparison IEC 60373
Frequency: 125 Hz to 4 kHz
Internal NMI service identifier: CENAM/510-F012-011