Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (8)
PHYSICS
Impedance up to the MHz range (8)
Inductance: self inductance, intermediate values (4)
Capacitance: meters (1)
Inductance: self inductance, high values (1)
Inductance: meters (1)
Inductance: self inductance, low values (1)
Capacitance: low loss capacitors
Capacitance: dielectric capacitors
GEOGRAPHIC LOCATION
SIM (8)
Mexico (8)
Result of the search
Your query 'cenam' produced 8 results New search

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Electricity and Magnetism for Mexico (.PDF file)
Capacitance: meters. Capacitance bridge, LCR meter (capacitance), 0.001 nF to 1000 nF
Relative expanded uncertainty (k = 2, level of confidence 95%) in µF/F: 0.5 to 40
Direct measurement
Frequency: 1 kHz
Voltage: 1 mV to 50 V
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-004B
Uncertainty table
 
Inductance: meters. LCR meter (inductance), 0.1 mH to 10000 mH
Relative expanded uncertainty (k = 2, level of confidence 95%) in mH/H: 0.05 to 0.63
Direct measurement
Frequency: 1 kHz
Current: 10 µA to 30 mA
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-004B
Uncertainty table
 
Inductance: self inductance, intermediate values. Fixed inductor, 100 mH
Relative expanded uncertainty (k = 2, level of confidence 95%) in µH/H: 90
Substitution using an LCR meter
Frequency: 1 kHz
Current: 1 mA
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-010-04
 
Inductance: self inductance, intermediate values. Fixed inductor, 1 H
Relative expanded uncertainty (k = 2, level of confidence 95%) in mH/H: 0.11
Substitution using an LCR meter
Frequency: 1 kHz
Current: 100 µA
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-010-05
 
Inductance: self inductance, high values. Fixed inductor, 10 H
Relative expanded uncertainty (k = 2, level of confidence 95%) in mH/H: 0.16
Substitution using an LCR meter
Frequency: 1 kHz
Current: 10 µA
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-010-06
 
Inductance: self inductance, intermediate values. Fixed inductor, 1 mH
Relative expanded uncertainty (k = 2, level of confidence 95%) in mH/H: 0.10
Substitution using an LCR meter
Frequency: 1 kHz
Current: 30 mA
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-010-02
 
Inductance: self inductance, intermediate values. Fixed inductor, 10 mH
Relative expanded uncertainty (k = 2, level of confidence 95%) in µH/H: 50
Substitution using an LCR meter
Frequency: 1 kHz
Current: 6 mA
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-010-03
 
Inductance: self inductance, low values. Fixed inductor, 100 µH
Relative expanded uncertainty (k = 2, level of confidence 95%) in mH/H: 0.60
Substitution using an LCR meter
Frequency: 1 kHz
Current: 30 mA
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-010-01