| | | Mexico, CENAM (Centro Nacional de Metrologia) | |  | Complete CMCs in Electricity and Magnetism for Mexico (.PDF file)
|  | |
| Antenna properties: antenna factor. Dipole antenna, 0 dB/m to 40 dB/m | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in dB: 0.32 to 0.78 | | Standard Site Method (ANSI C63.5:2006) | | Frequency: 30 MHz to 1000 MHz | | Polarization: horizontal | | Environment: open area calibration test site | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-Z008-022-CC |
| | | Antenna properties: antenna factor. Biconical antenna, 0 dB/m to 40 dB/m | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in dB: 0.58 to 1.12 | | Standard Site Method (ANSI C63.5:2006) | | Frequency: 30 MHz to 300 MHz | | Polarization: horizontal | | Environment: open area calibration test site | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-Z008-021-CC |
| | | Antenna properties: antenna factor. Log periodic antenna, 0 dB/m to 40 dB/m | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in dB: 0.46 to 1.12 | | Standard Site Method (ANSI C63.5:2006) | | Frequency: 200 MHz to 1000 MHz | | Polarization: horizontal | | Environment: open area calibration test site | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-Z008-020-CC |
| | | Antenna properties: antenna factor. Hybrid antenna, 0 dB/m to 40 dB/m | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in dB: 0.67 to 2.06 | | Standard Site Method (ANSI C63.5:2006) | | Frequency biconical part: 30 MHz to 300 MHz | | Polarization: horizontal | | Environment: open area calibration test site | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-Z008-022-CC |
| | | Antenna properties: antenna factor. Hybrid antenna, 0 dB/m to 40 dB/m | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in dB: 0.67 to 2.06 | | Standard Site Method (ANSI C63.5:2006) | | Frequency Log-Per part: 200 MHz to 1000 MHz | | Polarization: horizontal | | Environment: open area calibration test site | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-Z008-022-CC |
| | Phase angle: meters. Phase meter, 0 rad to 2 rad | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in µrad: 20 | | Direct comparison | | Voltage: 120 V, 240 V | | Current: 1 A, 5 A | | Frequency: 60 Hz | | Approved on 05 January 2012 | | Internal NMI service identifier: CENAM/E012-001I-CC |
| | | Reflection coefficient s22: on coaxial phase (with magnitude of reflection coefficient below or equal to 0.1). 2-port coaxial device, -180 ° to 180 ° | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in °: 2.65 to 180 | | Vector automatic network analyzer | | Frequency: 2 GHz to 10 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -004-CC, -007-CC | | Uncertainty table |
| | | Reflection coefficient s22: on coaxial phase (with magnitude of reflection coefficient below or equal to 0.1). 2-port coaxial device, -180 ° to 180 ° | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in °: 5.09 to 180 | | Vector automatic network analyzer | | Frequency: 10 GHz to 18 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -004-CC, -007-CC | | Uncertainty table |
| | | Reflection coefficient s22: on coaxial phase (with magnitude of reflection coefficient above or equal to 0.1). 2-port coaxial device, -180 ° to 180 ° | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in °: 1.79 to 2.22 | | Vector automatic network analyzer | | Frequency: 45 MHz to 2 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -004-CC, -007-CC | | Uncertainty table |
| | | Reflection coefficient s22: on coaxial phase (with magnitude of reflection coefficient above or equal to 0.1). 2-port coaxial device, -180 ° to 180 ° | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in °: 1.81 to 2.67 | | Vector automatic network analyzer | | Frequency: 2 GHz to 10 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -004-CC, -007-CC | | Uncertainty table |
| | | Reflection coefficient s22: on coaxial phase (with magnitude of reflection coefficient above or equal to 0.1). 2-port coaxial device, -180 ° to 180 ° | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in °: 3.56 to 5.18 | | Vector automatic network analyzer | | Frequency: 10 GHz to 18 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -004-CC, -007-CC | | Uncertainty table |
| | | Reflection coefficient: on coaxial magnitude. 1-port coaxial device, 0 to 1 | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%): 0.0040 to 0.0082 | | Vector automatic network analyzer | | Frequency: 45 MHz to 2 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -008-CC | | Uncertainty table |
| | | Reflection coefficient: on coaxial magnitude. 1-port coaxial device, 0 to 1 | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%): 0.0060 to 0.0128 | | Vector automatic network analyzer | | Frequency: 2 GHz to 10 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -008-CC | | Uncertainty table |
| | | Reflection coefficient: on coaxial magnitude. 1-port coaxial device, 0 to 1 | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%): 0.0112 to 0.0159 | | Vector automatic network analyzer | | Frequency: 10 GHz to 18 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -008-CC | | Uncertainty table |
| | | Reflection coefficient: on coaxial phase (with magnitude of reflection coefficient below or equal to 0.1). 1-port coaxial device, -180 ° to 180 ° | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in °: 1.35 to 180 | | Vector automatic network analyzer | | Frequency: 45 MHz to 2 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -008-CC | | Uncertainty table |
| | | Reflection coefficient: on coaxial phase (with magnitude of reflection coefficient below or equal to 0.1). 1-port coaxial device, -180 ° to 180 ° | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in º: 1.99 to 180 | | Vector automatic network analyzer | | Frequency: 2 GHz to 10 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -008-CC | | Uncertainty table |
| | | Reflection coefficient: on coaxial phase (with magnitude of reflection coefficient below or equal to 0.1). 1-port coaxial device, -180 ° to 180 ° | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in °: 3.71 to 180 | | Vector automatic network analyzer | | Frequency: 10 GHz to 18 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -008-CC | | Uncertainty table |
| | | Transmission coefficient: on coaxial magnitude. 2-port coaxial device, 0 dB to 20 dB | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in dB: 0.023 to 0.072 | | Vector automatic network analyzer | | Frequency: 2 GHz to 18 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-(001, 002, 003, 004, 007)-CC | | Uncertainty table |
| | | Transmission coefficient: on coaxial magnitude. 2-port coaxial device, 20 dB to 50 dB | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in dB: 0.035 to 0.193 | | Vector automatic network analyzer | | Frequency: 45 MHz to 1 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-(001, 002, 003, 004, 007)-CC | | Uncertainty table |
| | | Transmission coefficient: on coaxial magnitude. 2-port coaxial device, 20 dB to 50 dB | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in dB: 0.036 to 0.081 | | Vector automatic network analyzer | | Frequency: 1 GHz to 2 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-(001, 002, 003, 004, 007)-CC | | Uncertainty table |
|