Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (15)
PHYSICS
DC voltage, current, and resistance
Pressure (15)
Absolute pressure gas medium (9)
Gauge pressure gas medium (5)
Differential pressure gas medium (1)
Gauge pressure liquid medium
CHEMICAL MATERIAL
sediment
organic solution, multi-component
CHEMICAL ANALYTE
chromium
GEOGRAPHIC LOCATION
SIM (15)
Mexico (15)
Result of the search
Your query 'cenam' produced 15 results New search

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Mass and related quantities for Mexico (.PDF file)
Absolute pressure gas medium. Low pressure gauges, 1 kPa to 120 kPa
Absolute expanded uncertainty (k = 2, level of confidence 95%) in Pa: 0.5 to 2.5
Direct comparison with standard
Temperature: 20 °C
Internal NMI service identifier: CENAM/720-F002-002
 
Absolute pressure gas medium. Pressure measuring devices, 0.0001 Pa to 1 Pa
Relative expanded uncertainty (k = 2, level of confidence 95%): 9.00E-03
Direct comparison with standard
Temperature: 23 °C
Internal NMI service identifier: CENAM/720-F006-001
 
Absolute pressure gas medium. Pressure measuring devices, 1 Pa to 10 Pa
Relative expanded uncertainty (k = 2, level of confidence 95%): 3.50E-03
Direct comparison with standard
Temperature: 23 °C
Internal NMI service identifier: CENAM/720-F006-001
 
Absolute pressure gas medium. Pressure measuring devices, 10 Pa to 100 Pa
Relative expanded uncertainty (k = 2, level of confidence 95%): 2.50E-03
Direct comparison with standard
Temperature: 23 °C
Internal NMI service identifier: CENAM/720-F006-001
 
Absolute pressure gas medium. Pressure measuring devices, 100 Pa to 1 000 Pa
Relative expanded uncertainty (k = 2, level of confidence 95%): 2.50E-03
Direct comparison with standard
Temperature: 23 °C
Internal NMI service identifier: CENAM/720-F006-001
 
Differential pressure gas medium. Low pressure gauges, 5.00E-03 kPa to 150 kPa
Relative expanded uncertainty (k = 2, level of confidence 95%) in kPa: (15E-06 pl) + (15E-06 ps)
Direct comparison with standard
Temperature: 20 °C
Line pressure plplmax = 150 kPa
Standard pressure pspdiff = ps - pl
Internal NMI service identifier: CENAM/720-F002-005
 
Absolute pressure gas medium. Pressure measuring devices, 10 kPa to 175 kPa
Relative expanded uncertainty (k = 2, level of confidence 95%): 1.50E-05
Direct comparison with standard
Temperature: 20 °C
Internal NMI service identifier: CENAM/720-F002-001, 002, 003, 004
 
Gauge pressure gas medium. Pressure measuring devices, 10 kPa to 175 kPa
Relative expanded uncertainty (k = 2, level of confidence 95%): 1.50E-05
Direct comparison with standard
Temperature: 20 °C
Internal NMI service identifier: CENAM/720-F002-001, 002, 003, 004
 
Absolute pressure gas medium. Pressure measuring devices, 175 kPa to 350 kPa
Relative expanded uncertainty (k = 2, level of confidence 95%): 1.80E-05
Direct comparison with standard
Temperature: 20 °C
Internal NMI service identifier: CENAM/720-F002-001, 002, 003, 004
 
Gauge pressure gas medium. Pressure measuring devices, 175 kPa to 350 kPa
Relative expanded uncertainty (k = 2, level of confidence 95%): 1.80E-05
Direct comparison with standard
Temperature: 20 °C
Internal NMI service identifier: CENAM/720-F002-001, 002, 003, 004
 
Absolute pressure gas medium. Pressure measuring devices, 0.35 MPa to 1.75 MPa
Relative expanded uncertainty (k = 2, level of confidence 95%): 2.60E-05
Direct comparison with standard
Temperature: 20 °C
Internal NMI service identifier: CENAM/720-F002-001, 002, 003, 004
 
Gauge pressure gas medium. Pressure measuring devices, 0.35 MPa to 1.75 MPa
Relative expanded uncertainty (k = 2, level of confidence 95%): 2.60E-05
Direct comparison with standard
Temperature: 20 °C
Internal NMI service identifier: CENAM/720-F002-001, 002, 003, 004
 
Absolute pressure gas medium. Pressure measuring devices, 1.75 MPa to 7 MPa
Relative expanded uncertainty (k = 2, level of confidence 95%): 3.80E-05
Direct comparison with standard
Temperature: 20 °C
Internal NMI service identifier: CENAM/720-F002-001, 002, 003, 004
 
Gauge pressure gas medium. Pressure measuring devices, 1.75 MPa to 7 MPa
Relative expanded uncertainty (k = 2, level of confidence 95%): 3.80E-05
Direct comparison with standard
Temperature: 20 °C
Internal NMI service identifier: CENAM/720-F002-001, 002, 003, 004
 
Gauge pressure gas medium. Pressure measuring devices, 7 MPa to 80 MPa
Relative expanded uncertainty (k = 2, level of confidence 95%): 5.00E-05
Direct comparison with standard
Temperature: 20 °C
Internal NMI service identifier: CENAM/720-F001-001, 720-F001-002