Refine your search |
|
CMC AREA |
|
|
|
|
PHYSICS |
|
|
|
|
|
CHEMICAL MATERIAL |
|
|
|
|
|
CHEMICAL ANALYTE |
|
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
|
Your query 'cenam' produced 544 results
|
New search
|
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in mg/kg
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in mmol/l
|
Absolute
expanded uncertainty
(k = 2, 95%)
in mmol/l
|
|
human serum
|
creatinine |
4
to 7
|
3.7
|
0.0664
|
0.0032
|
Mechanism(s) for measurement service delivery:
DMR 263a
Approved on 12 June 2007.
Internal NMI service identifier: CENAM/630-C014-001b
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
iron
|
molybdenum |
2
to 11
|
2.8
|
Mechanism(s) for measurement service delivery:
Analytical service, reference materials: DES-025, DES-026, DES-027, DES-028
Approved on 31 March 2012.
Internal NMI service identifier: CENAM/610-024
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/kg
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
polyethylene
|
mercury |
300
to 600
|
3
to 5
|
Mechanism(s) for measurement service delivery:
Value-assignment through MRTC program
MRTC program: certification of a batch produced and later distributed by an external manufacturer. Uncertainty convention 1. Approved on 31 March 2012.
Internal NMI service identifier: CENAM/620-Q004-1
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
p-xylene
|
p-xylene |
98.0
to 100
|
0.1
to 0.6
|
Mechanism(s) for measurement service delivery:
DMR-232
Uncertainty range convention 1. Approved on 29 April 2005.
Internal NMI service identifier: CENAM/630-C014-003
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in ng/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
solvent solution
|
cis-chlordane |
10
to 600
|
2
to 10
|
Mechanism(s) for measurement service delivery:
Analytical services, PT 630-IL-1203
Uncertainty convention 1. Approved on 01 March 2005.
Internal NMI service identifier: CENAM/630-Q021-005
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
aluminum
|
zinc |
0.4
to 1.7
|
1.4
|
Mechanism(s) for measurement service delivery:
Analytical service, reference materials: DES-036, DES-037, DES-038, DES-039, DES-040, DES-052, DES-053, DES-054, DES-055, DES-056, DES-057, DES-058, DES-059, DES-060, DES-061, DES-062, DES-063, DES-064, DES-065, DES-066
Approved on 12 June 2007.
Internal NMI service identifier: CENAM/610-025
| Matrix or material |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
pH
|
Absolute
expanded uncertainty
(k = 2, 95%)
|
pH
|
Absolute
expanded uncertainty
(k = 2, 95%)
|
|
aqueous pH buffer solution
|
10.000
to 10.040
|
0.007
|
10.000
to 10.040
|
0.007
to 0.010
|
Mechanism(s) for measurement service delivery:
DMR-324 I / II
Temperature range for service: 15 °C to 37 °C, values given for 25°C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention (~0.010, k=2). Uncertainty convention 1. Approved on 31 March 2012.
Internal NMI service identifier: CENAM/630-Q024-001.P10
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
benzene
|
benzene |
98.0
to 100
|
0.1
to 0.6
|
Mechanism(s) for measurement service delivery:
DMR-284a
Uncertainty range convention 1. Approved on 29 April 2005.
Internal NMI service identifier: CENAM/630-C014-004
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/kg
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
ceramics
|
aluminum |
700
to 1000
|
4
to 5
|
Mechanism(s) for measurement service delivery:
Value-assignment through MRTC program
MRTC program: certification of a batch produced and later distributed by an external manufacturer. Uncertainty convention 1. Approved on 31 March 2012.
Internal NMI service identifier: CENAM/610-038
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount of sustance fraction
in µmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
propane |
50
to 50000
|
2
|
Mechanism(s) for measurement service delivery:
Program for value-assignment to gas mixture from producers (MRTC), calibration services and analytical services
Approved on 27 March 2013.
Internal NMI service identifier: CENAM/630-QS01.G003
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/kg
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
human serum
|
creatinine |
20
to 40
|
2.7
|
Mechanism(s) for measurement service delivery:
Proficiency test and analytical service
Approved on 12 June 2007.
Internal NMI service identifier: CENAM/630-C014-002b
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in µg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
milk powder
|
vitamin E (a-tocopherol) |
11
to 400
|
11
to 17
|
34
to 80
|
11
to 17
|
Mechanism(s) for measurement service delivery:
DMR-273a, DMR-274a, Proficiency test 630-Q016-005-PA
Uncertainty range convention 1. Approved on 01 March 2005.
Internal NMI service identifier: CENAM/630-Q016-001
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in ng/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
solvent solution
|
trans-nonachlor |
10
to 600
|
1
to 10
|
Mechanism(s) for measurement service delivery:
Analytical services, PT 630-IL-1203
Uncertainty convention 1. Approved on 01 March 2005.
Internal NMI service identifier: CENAM/630-Q021-006
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
aluminum
|
copper |
0.1
to 1.5
|
3.2
|
Mechanism(s) for measurement service delivery:
Analytical service, reference materials: DES-036, DES-037, DES-038, DES-039, DES-040, DES-052, DES-053, DES-054, DES-055, DES-056, DES-057, DES-058, DES-059, DES-060, DES-061, DES-062, DES-063, DES-064, DES-065, DES-066
Approved on 12 June 2007.
Internal NMI service identifier: CENAM/610-026
| Matrix or material |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
pH
|
Absolute
expanded uncertainty
(k = 2, 95%)
|
pH
|
Absolute
expanded uncertainty
(k = 2, 95%)
|
|
aqueous pH buffer solution
|
4.000
to 4.030
|
0.011
|
4.000
to 4.030
|
0.012
|
Mechanism(s) for measurement service delivery:
MRTC program (certification of a batch produced and latter distributed by an external manufacturer)
Temperature range for service and given values: 25°C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention (~0.010, k=2). Uncertainty convention 1. Approved on 31 March 2012.
Internal NMI service identifier: CENAM/630-Q024- 001.s4
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/kg
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
ceramics
|
calcium |
40
to 120
|
6
to 7
|
Mechanism(s) for measurement service delivery:
Value-assignment through MRTC program
MRTC program: certification of a batch produced and later distributed by an external manufacturer. Uncertainty convention 1. Approved on 31 March 2012.
Internal NMI service identifier: CENAM/610-039
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount of sustance fraction
in µmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
carbon dioxide |
100
to 200000
|
1.5
|
Mechanism(s) for measurement service delivery:
Program for value-assignment to gas mixture from producers (MRTC), calibration services and analytical services
Approved on 27 March 2013.
Internal NMI service identifier: CENAM/630-QS01.G004
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/kg
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
sea food
|
zinc |
30
to 90
|
3.6
to 5
|
Mechanism(s) for measurement service delivery:
Value-assignment through MRTC program and PT program
Uncertainty range convention 1. Approved on 24 June 2008.
Internal NMI service identifier: CENAM/620-Q008-19
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in ng/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
solvent solution
|
4,4'-DDD |
10
to 600
|
1
to 10
|
Mechanism(s) for measurement service delivery:
Analytical services, PT 630-IL-1203
Uncertainty convention 1. Approved on 01 March 2005.
Internal NMI service identifier: CENAM/630-Q021-008
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
toluene
|
toluene |
98.0
to 100
|
0.1
to 0.6
|
Mechanism(s) for measurement service delivery:
DMR-285a
Uncertainty range convention 1. Approved on 29 April 2005.
Internal NMI service identifier: CENAM/630-C014-005
|