Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (28)
PHYSICS
DC voltage, current, and resistance (28)
DC voltage, DC voltage meters, intermediate values (6)
DC resistance, DC resistance standards and sources, intermediate values (6)
DC current, DC current sources, intermediate values (5)
DC current, DC current meters, intermediate values (5)
DC voltage, DC voltage sources, intermediate values (2)
DC resistance, DC resistance standards and sources, low values (1)
DC resistance, DC resistance meters, low values (1)
DC current, DC current sources, low values (1)
DC current, DC current meters, low values (1)
DC voltage, DC voltage sources, low value ranges
DC resistance, DC resistance meters, intermediate values
DC resistance, DC resistance standards and sources, high values
DC resistance, DC resistance meters, high values
GEOGRAPHIC LOCATION
SIM (28)
Costa Rica (28)
Result of the search
Your query 'Costa Rica' produced 28 results New search
1  2

 
Costa Rica, ICE-LMVE (Instituto Costarricense de Electricidad, Laboratorio Metrológico de Variables Eléctricas)
Complete CMCs in Electricity and Magnetism for Costa Rica (.PDF file)
DC voltage, DC voltage sources, intermediate values. DC voltage source, multifunction calibrator, > 10 V to 100 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 4.9 to 6.4
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/11301
 
DC voltage, DC voltage sources, intermediate values. DC voltage source, multifunction calibrator, 100 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 6.4 to 15.6
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/11302
 
DC voltage, DC voltage meters, intermediate values. DC voltmeter, multimeter, > 0.001 V to 0.01 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 48 to 416
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/12201
 
DC voltage, DC voltage meters, intermediate values. DC voltmeter, multimeter, 0.01 V to 0.1 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 12 to 48
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/12202
 
DC voltage, DC voltage meters, intermediate values. DC voltmeter, multimeter, 0.1 V to 1 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 5.8 to 12
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/12203
 
DC voltage, DC voltage meters, intermediate values. DC voltmeter, multimeter, 1 V to 10 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 3.8 to 5.8
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/12204
 
DC voltage, DC voltage meters, intermediate values. DC voltmeter, multimeter, 10 V to 100 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 3.8 to 5.5
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/12205
 
DC voltage, DC voltage meters, intermediate values. DC voltmeter, multimeter, 100 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 5.5 to 7.0
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/12206
 
DC resistance, DC resistance standards and sources, low values. Fixed resistor, resistance box, 0.1 to 1
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 53 to 402
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21101
 
DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, > 1 to 10
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 18 to 53
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21201
 
DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, 10 to 100
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 16 to 50
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21202
 
DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, 100 to 1000
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 10 to 14
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21203
 
DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, 1 k to 10 k
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 10 to 14
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21204
 
DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, 10 k to 100 k
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 10 to 14
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21205
 
DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, 100 k to 1000 k
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 16 to 30
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21206
 
DC resistance, DC resistance meters, low values. Multimeter, 1
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 97
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/22101
 
DC current, DC current sources, low values. Multifunction calibrator, current generator, 0.01 mA to 0.1 mA
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 26 to 82
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/31101
 
DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, > 0.1 mA to 1 mA
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 23 to 59
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/31201
 
DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, 1 mA to 10 mA
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 23 to 59
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/31202
 
DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, 10 mA to 100 mA
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 35 to 70
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/31203