Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Chemistry (300)
CMCs General Physics (268)
PHYSICS >
Impedance up to the MHz range
Torque, Viscosity, Hardness and Gravity
Properties of detectors and sources
Radio frequency measurements (52)
Mass, mass standards (28)
Sound in air (23)
Dimensional metrology (20)
Density (20)
Pressure (18)
Vibration (16)
Fluid flow (16)
Force (15)
AC voltage, current, and power (15)
Temperature (15)
Photometry (7)
CHEMICAL MATERIAL >
sediment (20)
organic solution, multi-component (20)
HNO3 in aqueous solution (19)
soil (16)
particulates (16)
CHEMICAL ANALYTE >
chromium
lead (9)
cadmium (8)
zinc (7)
acenaphthene (5)
naphthalene (5)
GEOGRAPHIC LOCATION
SIM (568)
Mexico (568)
Result of the search
Your query 'cenam' produced 568 results New search
[<< Prev] 28  29

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Electricity and Magnetism for Mexico (.PDF file)
AC voltage up to 1000 V: meters. Multimeter, 0.002 V to 1000 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 12 to 600
Direct comparison
Frequency: 10 Hz to 1 MHz
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E010-001-02-a
Uncertainty table
 
AC-DC current transfer: AC-DC transfer difference. Thermal converter plus shunt, 0.001 A to 20 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 30 to 115
Direct comparison
Frequency: 40 Hz to 5 kHz
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E010-006-01-a
Uncertainty table
 
AC current up to 100 A: sources. Multifunction calibrator, 0.001 A to 20 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 35 to 120
Direct comparison
Frequency: 40 Hz to 5 kHz
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E010-004-01-a
Uncertainty table
 
AC current up to 100 A: meters. Multimeter, 0.001 A to 20 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 35 to 800
Direct measurement using a characterized calibrator
Frequency: 40 Hz to 5 kHz
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E003-002-52-a
Uncertainty table
 
AC power and energy: single phase (frequency <= 400 Hz, active power). Multifunction calibrators, 60 W to 2.4E+03 W
Relative expanded uncertainty (k = 2, level of confidence 95%) in µW/VA: 100
Direct comparison
Voltage: 120 V, 240 V
Current: 1 A, 10 A
Power factor: 1 to 0.5, inductive or capactive
Frequency: 60 Hz
Approved on 05 January 2012
Internal NMI service identifier: CENAM/E012-001B-CC
 
AC power and energy: single phase (frequency <= 400 Hz, active power). Power meter, 0 W to 6E+04 W
Relative expanded uncertainty (k = 2, level of confidence 95%) in µW/VA: 20 to 30
Direct comparison
Voltage: 120 V, 240 V, 480 V, 600 V
Current: 0.25 A to 100 A
Power factor: 1 to 0, inductive or capacitive
Frequency: 60 Hz
Approved on 05 January 2012
Internal NMI service identifier: CENAM/E012-001-01
Uncertainty table
 
AC power and energy: single phase (frequency <= 400 Hz, reactive power). VAR meter, 0 var to 6E+04 var
Relative expanded uncertainty (k = 2, level of confidence 95%) in µvar/VA: 20 to 30
Direct comparison
Voltage: 120 V, 240 V, 480 V, 600 V
Current: 0.25 A to 100 A
Power factor: 1 to 0, inductive or capacitive
Frequency: 60 Hz
Approved on 05 January 2012
Internal NMI service identifier: CENAM/E012-001-02
Uncertainty table
 
AC power and energy: single phase (frequency <= 400 Hz, apparent power). VA meter, 30 VA to 6E+04 VA
Relative expanded uncertainty (k = 2, level of confidence 95%) in µVA/VA: 20 to 30
Direct comparison
Voltage: 120 V, 240 V, 480 V, 600 V
Current: 0.25 A to 100 A
Power factor: 1 to 0, inductive or capacitive
Frequency: 60 Hz
Approved on 05 January 2012
Internal NMI service identifier: CENAM/E012-001-03
Uncertainty table
 
AC power and energy: single phase (frequency <= 400 Hz, active energy). Watt-hour meter, 0 J to 7.2E+06 J
Relative expanded uncertainty (k = 2, level of confidence 95%) in µJ/VAs: 20 to 30
Direct comparison
Voltage: 120 V, 240 V, 480 V, 600 V
Current: 0.25 A to 100 A
Power factor: 1 to 0, inductive or capacitive
Frequency: 60 Hz
Measurement time: 120 s
Approved on 05 January 2012
Internal NMI service identifier: CENAM/E012-001-04
Uncertainty table
 
AC power and energy: single phase (frequency <= 400 Hz, reactive energy). VAR-hour meter, 0 vars to 7.2E+06 vars
Relative expanded uncertainty (k = 2, level of confidence 95%) in µvars/VAs: 20 to 30
Direct comparison
Voltage: 120 V, 240 V, 480 V, 600 V
Current: 0.25 A to 100 A
Power factor: 1 to 0, inductive or capacitive
Frequency: 60 Hz
Measurement time: 120 s
Approved on 05 January 2012
Internal NMI service identifier: CENAM/E012-001-05
Uncertainty table
 
AC power and energy: single phase (frequency <= 400 Hz, apparent energy). VA-hour meter, 3.6E+03 VAs to 7.2E+06 VAs
Relative expanded uncertainty (k = 2, level of confidence 95%) in µVAs/VAs: 20 to 30
Direct comparison
Voltage: 120 V, 240 V, 480 V, 600 V
Current: 0.25 A to 100 A
Power factor: 1 to 0, inductive or capacitive
Frequency: 60 Hz
Measurement time: 120 s
Approved on 05 January 2012
Internal NMI service identifier: CENAM/E012-001-06
Uncertainty table
 
DC voltage sources: single values. Solid state voltage standard, 1 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 0.3
Ratio technique from 1.018 V to 1 V via a DVM
Room temperature: 23 °C
Ambient pressure: 81 kPa
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E011-003-01
 
DC voltage sources: single values. Solid state voltage standard, 1.018 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 0.3
Differential measurement using a redundant design
Room temperature: 23 °C
Ambient pressure: 81 kPa
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E011-003-02
 
DC voltage sources: single values. Solid state voltage standard, 10 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 0.3
Ratio technique from 1.018 V to 10 V via a DVM and a resistive divider
Room temperature: 23 °C
Ambient pressure: 81 kPa
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E011-003-03
 
Transmittance, diffuse, spectral. Spectrally-neutral material, 0 to 1
Absolute expanded uncertainty (k = 2, level of confidence ~95%): 0.003
Spectrophotometer
Wavelength: 240 nm to 900 nm
Bandwidth: 1 nm to 5 nm
Specific measurement conditions: normal incidence
Best measurement capability is valid only using PTB-certified white reference standard; the uncertainty increases for NPL certified references.
Internal NMI service identifier: CENAM/520-D006-004
 
Reflectance, diffuse, spectral. Spectrally-neutral material, 0.003 to 1
Absolute expanded uncertainty (k = 2, level of confidence ~95%): 0.002 to 0.003, varies with measurand
Spectrophotometer
Wavelength range: 380 nm to 780 nm
Bandwidth: 1 nm to 5 nm
Specific measurement conditions: 8°/d, 8°/t
Best measurement capability is valid only using PTB-certified white reference standard; the uncertainty increases for NPL certified references.
Internal NMI service identifier: CENAM/520-D006-003
 
Colour, surface, x, y, Y. General material. x and y, 0.0001 to 1
Absolute expanded uncertainty (k = 2, level of confidence ~95%): 0.006
Spectrophotometer
Specific measurement conditions: 8°/d, 8°/t
Type of material: reflecting material
Internal NMI service identifier: CENAM/520-D006-003
 
Colour, surface, x, y, Y. General material Y, 0 to 100
Absolute expanded uncertainty (k = 2, level of confidence ~95%): 0.21
Spectrophotometer
Specific measurement conditions: 8°/d, 8°/t
Type of material: reflecting material
Internal NMI service identifier: CENAM/520-D006-003
 
Wavelength. Optical spectrum analyser, 600 nm to 1600 nm
Absolute expanded uncertainty (k = 2, level of confidence ~95%) in nm: 0.03
Approved on 21 September 2005
Internal NMI service identifier: CENAM/520-D003-008
 
Fibre optics. Length. Single-mode optical fibre, 1 km to 15 km
Absolute expanded uncertainty (k = 2, level of confidence ~95%) in m: 0.1
Phase shift method
Wavelength: 1310 nm, 1550 nm, 1625 nm
Standard used: vectorial network analyzer
Approved on 29 June 2010