Refine your search |
|
CMC AREA |
|
|
|
|
PHYSICS |
|
|
|
|
CHEMICAL MATERIAL |
|
|
|
|
CHEMICAL ANALYTE |
|
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount of sustance fraction
in µmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
carbon monoxide |
10
to 80000
|
3
to 1
|
Mechanism(s) for measurement service delivery:
Program for value-assignment to gas mixture from producers (MRTC), calibration services and analytical services
Uncertainty convention 2. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/630-QS01.G001
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount-of-substance fraction
in µmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
nitrogen monoxide |
100
to 10000
|
0.6
to 1
|
Mechanism(s) for measurement service delivery:
Program for value-assignment to gas mixture from producers (MRTC), calibration services and analytical services
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/630-QS01.G002
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount of sustance fraction
in µmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
propane |
50
to 50000
|
2
|
Mechanism(s) for measurement service delivery:
Program for value-assignment to gas mixture from producers (MRTC), calibration services and analytical services
Approved on 27 March 2013.
Internal NMI service identifier: CENAM/630-QS01.G003
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount of sustance fraction
in µmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
carbon dioxide |
100
to 200000
|
1.5
|
Mechanism(s) for measurement service delivery:
Program for value-assignment to gas mixture from producers (MRTC), calibration services and analytical services
Approved on 27 March 2013.
Internal NMI service identifier: CENAM/630-QS01.G004
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount of substance
in µmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
carbon dioxide |
300
to 450
|
1.5
|
Mechanism(s) for measurement service delivery:
Program for value-assignment to gas mixture from producers (MRTC)
Approved on 19 July 2010.
Internal NMI service identifier: CENAM/630-QS01.G-006
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount of sustance fraction
in nmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
nitrogen monoxide |
600
to 850
|
1.4
to 2.0
|
Mechanism(s) for measurement service delivery:
Program for value-assignment to gas mixture from producers (MRTC), calibration services and analytical services
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/630-QS01.G011
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount of sustance fraction
in µmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
nitrogen monoxide |
1.0
to 1.5
|
1.4
to 2.0
|
Mechanism(s) for measurement service delivery:
Program for value-assignment to gas mixture from producers (MRTC), calibration services and analytical services
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/630-QS01.G014
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount of sustance fraction
in µmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
nitrogen monoxide |
30
to 70
|
0.6
to 1.0
|
Mechanism(s) for measurement service delivery:
Program for value-assignment to gas mixture from producers (MRTC), calibration services and analytical services
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/630-QS01.G016
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount of sustance fraction
in µmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
oxygen |
10
to 250000
|
1.5
|
Mechanism(s) for measurement service delivery:
Program for value-assignment to gas mixture from producers (MRTC), calibration services and analytical services
Approved on 27 March 2013.
Internal NMI service identifier: CENAM/630-QS01.G018
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount of sustance fraction
in µmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
carbon monoxide |
1
to 10
|
3
|
Mechanism(s) for measurement service delivery:
Program for value-assignment to gas mixture from producers (MRTC), calibration services and analytical services
Approved on 27 March 2013.
Internal NMI service identifier: CENAM/630-QS01.G009
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount-of- substance fraction
in µmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
sulfur dioxide |
100
to 10000
|
0.7
|
Mechanism(s) for measurement service delivery:
MRTC-Program, calibration services and analytical services
Approved on 27 March 2013.
Internal NMI service identifier: CENAM/630-QS01.G008
|