Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Chemistry
CMCs General Physics (291)
PHYSICS >
Vibration
Radio frequency measurements (52)
Mass, mass standards (28)
Sound in air (23)
Dimensional metrology (20)
Density (20)
Pressure (18)
Fluid flow (16)
Impedance up to the MHz range (16)
Torque, Viscosity, Hardness and Gravity (15)
Force (15)
AC voltage, current, and power (15)
Temperature (15)
CHEMICAL ANALYTE
zinc
chromium
fluoranthene
GEOGRAPHIC LOCATION
SIM (291)
Mexico (291)
Result of the search
Your query 'cenam' produced 291 results New search
[<< Prev] 6  7  8 [Next >>]

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Mass and related quantities for Mexico (.PDF file)
Volume of liquid. Volumetric test measure (pipette, burette, flask), 1 cm3 to 10 cm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.05
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV10
 
Volume of liquid. Volumetric test measure (pipette, burette, flask), 10 cm3 to 2000 cm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.01
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV11
 
Volume of liquid. Volumetric test measure (pycnometer), 10 cm3 to 100 cm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.004
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV12
 
Volume of liquid. Volumetric test measure (graduated neck type), 2 dm3 to 50 dm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.015
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV13
 
Volume of liquid. Volumetric test measure (overflow type pipette), 5 dm3 to 50 dm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.005
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV14
 
Volume of liquid. Volumetric test measure (graduated neck type), 50 dm3 to 3000 dm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.02
Volumetric transfer
Temperature: 18 °C to 26 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV15
 
Volume of liquid. Volume quantity meter, 50 dm3 to 3000 dm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.06
Turbine and positive displacement meter
Temperature: 18 °C to 26 °C
Kinematic viscosity: 0.5 mm2/s to 5 mm2/s
Flow: < 50 dm3/s
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV16
 
Kinematic viscosity. Newtonian liquids, 0.003 mm2/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.22
Capillary viscometer
Temperature: 20 °C
Uncertainty statement corresponds to a reference temperature of 20 °C
Approved on 22 June 2006
Internal NMI service identifier: CENAM/1
 
Kinematic viscosity. Newtonian liquids, 0.1 mm2/s2 to 3 mm2/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.26
Capillary viscometer
Temperature: 20 °C
Uncertainty statement corresponds to a reference temperature of 20 °C
Approved on 22 June 2006
Internal NMI service identifier: CENAM/2
 
Kinematic viscosity. Newtonian liquids, 10 mm2/s2 to 30 mm2/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.36
Capillary viscometer
Temperature: 20 °C
Uncertainty statement corresponds to a reference temperature of 20 °C
Approved on 22 June 2006
Internal NMI service identifier: CENAM/3
 
Kinematic viscosity. Newtonian liquids, 0.9 mm2/s to 1.2 mm2/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.24
Reference liquid
Temperature: 40 °C to 20 °C
Uncertainty statement corresponds to a reference temperature of 20 °C
Approved on 22 June 2006
Internal NMI service identifier: CENAM/4
 
Kinematic viscosity. Newtonian liquids, 5 mm2/s to 22 mm2/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.30
Reference liquid
Temperature: 40 °C to 20 °C
Uncertainty statement corresponds to a reference temperature of 20 °C
Approved on 22 June 2006
Internal NMI service identifier: CENAM/5
 
Kinematic viscosity. Newtonian liquids, 3.5 mm2/s to 1800 mm2/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.35
Reference liquid
Temperature: 100 °C to 20 °C
Uncertainty statement corresponds to a reference temperature of 20 °C
Approved on 22 June 2006
Internal NMI service identifier: CENAM/6
 
Kinematic viscosity. Newtonian liquids, 80 mm2/s to 11600 mm2/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.40
Reference liquid
Temperature: 100 °C to 20 ºC
Uncertainty statement corresponds to a reference temperature of 20 °C
Approved on 22 June 2006
Internal NMI service identifier: CENAM/7
 
Kinematic viscosity. Newtonian liquids, 160 mm2/s to 35000 mm2/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.60
Reference liquid
Temperature: 100 °C to 20 ºC
Uncertainty statement corresponds to a reference temperature of 20 °C
Approved on 22 June 2006
Internal NMI service identifier: CENAM/8
 
Kinematic viscosity. Newtonian liquids, 200 mm2/s to 100000 mm2/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.70
Reference liquid
Temperature: 100 °C to 20 ºC
Uncertainty statement corresponds to a reference temperature of 20 °C
Approved on 22 June 2006
Internal NMI service identifier: CENAM/9
 
Kinematic viscosity. Newtonian liquids, 650 mm2/s to 326000 mm2/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.80
Reference liquid
Temperature: 100 °C to 20 ºC
Uncertainty statement corresponds to a reference temperature of 20 °C
Approved on 22 June 2006
Internal NMI service identifier: CENAM/10
 
Kinematic viscosity. Newtonian liquids, 3000 mm2/s to 770000 mm2/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.0
Reference liquid
Temperature: 100 °C to 20 ºC
Uncertainty statement corresponds to a reference temperature of 20 °C
Approved on 22 June 2006
Internal NMI service identifier: CENAM/11
 
Volume water flow rate. Liquid volume flow meters, 0.42 dm3/s to 200 dm3/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.040
Volumetric flowmeter (e.g., positive displacement, rotary piston, turbine, venturi, nozzle, ultrasonic, orifice plate, vortex meter, electromagnetic)
Fluid: water
Pressure: 0.1 MPa to 1 MPa
Temperature: 18 °C to 26 °C
Pipe sizes: 25 mm to 200 mm
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV1
 
Volume hydrocarbon flow rate. Oil flow meters, 0.00067 dm3/s to 1.67 dm3/s
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.060
Volumetric flowmeter (e.g., positive displacement, rotary piston, turbine, ultrasonic)
Kinematic viscosity: 0.5 mm2/s to 10 mm2/s
Pressure: 0.3 MPa to 0.6 MPa
Temperature: 18 °C to 24 °C
Pipe sizes: 6 mm to 25 mm
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV2