Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Chemistry
CMCs General Physics (238)
PHYSICS >
Fluid flow
Force
Temperature
Sound in air
Radio frequency measurements (52)
Mass, mass standards (28)
Dimensional metrology (20)
Density (20)
Pressure (18)
Vibration (16)
Impedance up to the MHz range (16)
Torque, Viscosity, Hardness and Gravity (15)
AC voltage, current, and power (15)
Properties of detectors and sources (8)
Photometry (7)
Frequency (5)
GEOGRAPHIC LOCATION
SIM (238)
Mexico (238)
Result of the search
Your query 'cenam' produced 238 results New search
[Prev] 2  3  4 [Next >>]

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Length for Mexico (.PDF file)
CMM artefacts. Ball bar: ball spacing L, 10 mm to 1100 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µm: (0.4 + 0.6E-03L)
CMM and stylus, with gauge substitution
Approved on 14 June 2004
Internal NMI service identifier: CENAM/36
 
CMM artefacts. Ball and bore plates, L, 10 mm to 650 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µm: (0.6 + 0.9E-03L)
CMM and stylus, with gauge substitution and reversal methods
Approved on 14 June 2004
Internal NMI service identifier: CENAM/37
 
Charge sensitivity (phase shift). Accelerometer, 0 ° to 360 °
Absolute expanded uncertainty (k = 2, level of confidence 95%) in °: 2
Laser interferometry ISO 16063-11
Frequency: 50 Hz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F011-001
 
Voltage sensitivity (phase shift). Acceleration measuring chain, 0 ° to 360 °
Absolute expanded uncertainty (k = 2, level of confidence 95%) in °: 2
Laser interferometry ISO 16063-11
Frequency: 50 Hz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F011-001
 
Ultrasonic power. Ultrasonic source transducer, 0.01 W to 1 W
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 11
Radiation force balance IEC 1161
Frequency: 1 MHz to 10 MHz
Internal NMI service identifier: CENAM/510-F018-003
 
Charge sensitivity (magnitude). Accelerometer. Measurand unit, C/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1
Reciprocity ASA S2.2-1959 ISO-16063-1
Frequency: 100 Hz to 4 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F010-001
 
Charge sensitivity (magnitude). Accelerometer. Measurand unit, C/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.5
Laser interferometry ISO 16063-11
Frequency: 50 Hz to 1 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F011-001
 
Charge sensitivity (magnitude). Accelerometer. Measurand unit, C/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.8
Laser interferometry ISO 16063-11
Frequency: 1 kHz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F011-001
 
Charge sensitivity (magnitude). Accelerometer. Measurand unit, C/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 2
Laser interferometry ISO 16063-11
Frequency: 5 kHz to 8 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F011-001
 
Charge sensitivity (magnitude). Accelerometer. Measurand unit, C/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.2
Comparison, ISO 5347-3
Frequency: 50 Hz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F012-001
 
Voltage sensitivity (magnitude). Acceleration measuring chain. Measurand unit, V/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.5
Laser interferometry ISO 16063-11
Frequency: 50 Hz to 1 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F011-001
 
Voltage sensitivity (magnitude). Acceleration measuring chain. Measurand unit, V/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.2
Comparison, ISO 5347-3
Frequency: 50 Hz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F012-001
 
Voltage sensitivity (magnitude). Acceleration measuring chain. Measurand unit, V/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.7
Comparison, ISO 5347-3
Frequency: 50 Hz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F012-015
 
Acceleration. Acceleration measuring instrument, 10 m/s2 to 100 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.5
Laser interferometry ISO 16063-11
Frequency: 50 Hz to 1 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F011-001
 
Acceleration. Acceleration measuring instrument, 10 m/s2 to 100 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.8
Laser interferometry ISO 16063-11
Frequency: 1 kHz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F011-001
 
Acceleration. Acceleration measuring instrument, 10 m/s2 to 50 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.2
Comparison, ISO 5347-3
Frequency: 50 Hz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F019-001
 
Acceleration. Acceleration measuring instrument, 10 m/s2 to 50 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 2
Comparison, ISO 5347-3
Frequency: 50 Hz to 1 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-G'03-002
 
Acceleration. Calibrators, 10 m/s2 to 100 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1
Comparison, ISO 5347-3
Frequency: 80 Hz to 160 Hz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F012-009
 
Acceleration. Calibrators, 10 m/s2 to 100 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 2
Comparison, ISO 5347-3
Frequency: 50 Hz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F012-009
 
Time scale difference. Local clock, -1 s to +1 s
Absolute expanded uncertainty (k = 2, level of confidence 95%) in ns: 2
Local clock vs. UTC(CNM)
Averaging time: 1 hour
Approved on 25 February 2009