Refine your search |
|
CMC AREA |
|
|
|
|
PHYSICS |
|
|
|
|
|
CHEMICAL MATERIAL |
|
|
|
|
|
CHEMICAL ANALYTE |
|
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
|
Your query 'cenam' produced 520 results
|
New search
|
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/kg
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
sea food
|
zinc |
30
to 90
|
3.6
to 5
|
Mechanism(s) for measurement service delivery:
Value-assignment through MRTC program and PT program
Uncertainty range convention 1. Approved on 24 June 2008.
Internal NMI service identifier: CENAM/620-Q008-19
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in ng/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
solvent solution
|
4,4'-DDD |
10
to 600
|
1
to 10
|
Mechanism(s) for measurement service delivery:
Analytical services, PT 630-IL-1203
Uncertainty convention 1. Approved on 01 March 2005.
Internal NMI service identifier: CENAM/630-Q021-008
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
toluene
|
toluene |
98.0
to 100
|
0.1
to 0.6
|
Mechanism(s) for measurement service delivery:
DMR-285a
Uncertainty range convention 1. Approved on 29 April 2005.
Internal NMI service identifier: CENAM/630-C014-005
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
aluminum
|
iron |
0.7
to 3.7
|
3
|
Mechanism(s) for measurement service delivery:
Analytical service, reference materials: DES-036, DES-037, DES-038, DES-039, DES-040, DES-052, DES-053, DES-054, DES-055, DES-056, DES-057, DES-058, DES-059, DES-060, DES-061, DES-062, DES-063, DES-064, DES-065, DES-066
Approved on 12 June 2007.
Internal NMI service identifier: CENAM/610-027
| Matrix or material |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
pH
|
Absolute
expanded uncertainty
(k = 2, 95%)
|
pH
|
Absolute
expanded uncertainty
(k = 2, 95%)
|
|
aqueous pH buffer solution
|
6.840
to 6.900
|
0.010
|
6.840
to 6.900
|
0.011
to 0.012
|
Mechanism(s) for measurement service delivery:
MRTC program (certification of a batch produced and latter distributed by an external manufacturer)
Temperature range for service and given values: 25°C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention (~0.010, k=2). Uncertainty convention 1. Approved on 31 March 2012.
Internal NMI service identifier: CENAM/630-Q024-001.s7
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in %
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
ethanol
|
ethanol |
98
to 100
|
0.3
to 1
|
99.74
|
0.1
|
Mechanism(s) for measurement service delivery:
Analytical service, DMR-95, DMR-165 x
Uncertainty range convention 1. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-C014-006
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/kg
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
fresh water
|
copper |
10
to 30
|
2
to 4
|
Mechanism(s) for measurement service delivery:
Value-assignment through MRTC program
Approved on 27 March 2013. Uncertainty convention 1.
Internal NMI service identifier: CENAM/620-Q008-005
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in ng/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
organic solution
|
PCB 28 |
20
to 1000
|
6
to 10
|
Mechanism(s) for measurement service delivery:
Analytical service
Uncertainty convention 1. Approved on 01 March 2005.
Internal NMI service identifier: CENAM/630-QS03.001
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount-of-substance content
in nmol/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
rice
|
zinc |
300
to 400
|
3.0
to 4.0
|
Mechanism(s) for measurement service delivery:
Value-assignment through CENAM Traceable Reference Materials (MRTC)
Approved on 19 July 2010. Uncertainty convention 1.
Internal NMI service identifier: CENAM/620-Q008-017R
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
aluminum
|
manganese |
0.3
to 3.8
|
4
|
Mechanism(s) for measurement service delivery:
Analytical service, reference materials: DES-036, DES-037, DES-038, DES-039, DES-040, DES-052, DES-053, DES-054, DES-055, DES-056, DES-057, DES-058, DES-059, DES-060, DES-061, DES-062, DES-063, DES-064, DES-065, DES-066
Approved on 31 March 2012.
Internal NMI service identifier: CENAM/610-028
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount of sustance fraction
in µmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
methane |
10
to 50000
|
1
|
Mechanism(s) for measurement service delivery:
Program for value-assignment to gas mixture from producers (MRTC), calibration services and analytical services
Approved on 27 March 2013.
Internal NMI service identifier: CENAM/630-QS01.G010
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in %
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
isobutanol
|
isobutanol |
98
to 100
|
0.3
to 1
|
99.28
|
0.1
|
Mechanism(s) for measurement service delivery:
Analytical service, DMR-165 x, DMR 96b
Uncertainty range convention 1. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-C014-007
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/kg
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
fresh water
|
nickel |
40
to 80
|
1.6
to 3
|
Mechanism(s) for measurement service delivery:
Value-assignment through MRTC program
Approved on 27 March 2013. Uncertainty convention 1.
Internal NMI service identifier: CENAM/620-Q008-006
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount of substance
in µmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
carbon dioxide |
300
to 450
|
1.5
|
Mechanism(s) for measurement service delivery:
Program for value-assignment to gas mixture from producers (MRTC)
Approved on 19 July 2010.
Internal NMI service identifier: CENAM/630-QS01.G-006
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in ng/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
organic solution
|
PCB 101 |
20
to 1000
|
1
to 3
|
Mechanism(s) for measurement service delivery:
Analytical service
Uncertainty convention 1. Approved on 01 March 2005.
Internal NMI service identifier: CENAM/630-QS03.002
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount-of-substance content
in nmol/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
rice
|
cadmium |
2
to 14
|
1.7
to 3.0
|
Mechanism(s) for measurement service delivery:
Value-assignment through CENAM Traceable Reference Materials (MRTC)
Approved on 19 July 2010. Uncertainty convention 1.
Internal NMI service identifier: CENAM/620-Q008-016R
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in mg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in mg/g
|
Mass fraction
in mg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in mg/g
|
|
silica sand
|
total aluminum as aluminum oxide |
1.1
to 2
|
0.2
|
1.85
|
0.18
|
Mechanism(s) for measurement service delivery:
DMR 73a
Internal NMI service identifier: CENAM/610-003
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in %
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
acetaldehyde
|
acetaldehyde |
95.7
to 100
|
0.3
to 1
|
95.7
|
0.5
|
Mechanism(s) for measurement service delivery:
Analytical service
Uncertainty range convention 1. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-C014-008
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
aluminum
|
chromium |
0.1
to 0.8
|
2.8
|
Mechanism(s) for measurement service delivery:
Analytical service, reference materials: DES-036, DES-037, DES-038, DES-039, DES-040, DES-052, DES-053, DES-054, DES-055, DES-056, DES-057, DES-058, DES-059, DES-060, DES-061, DES-062, DES-063, DES-064, DES-065, DES-066
Approved on 12 June 2007.
Internal NMI service identifier: CENAM/610-029
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in ng/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
organic solution
|
4,4'-DDE |
8
to 600
|
3
to 10
|
Mechanism(s) for measurement service delivery:
Analytical services
Uncertainty convention 1. Approved on 01 March 2005.
Internal NMI service identifier: CENAM/630-Q021-010
|