Refine your search |
|
CMC AREA |
|
|
|
|
PHYSICS |
|
|
|
|
|
CHEMICAL MATERIAL |
|
|
|
|
|
CHEMICAL ANALYTE |
|
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
|
Your query 'cenam' produced 511 results
|
New search
|
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount-of-substance
in cmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
synthetic natural gas
|
ethane |
1
to 20
|
0.8
to 1.14
|
Mechanism(s) for measurement service delivery:
MRTC-Program and analytical services
Internal NMI service identifier: CENAM/630-QS01.G-007
This displays only one part of a multi-component CMC.
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount-of-substance
in cmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
synthetic natural gas
|
carbon dioxide |
0.1
to 5
|
0.6
to 0.8
|
Mechanism(s) for measurement service delivery:
MRTC-Program and analytical services
Internal NMI service identifier: CENAM/630-QS01.G-007
This displays only one part of a multi-component CMC.
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount-of-substance
in cmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
synthetic natural gas
|
nitrogen |
1
to 20
|
0.9
to 1.2
|
Mechanism(s) for measurement service delivery:
MRTC-Program and analytical services
Internal NMI service identifier: CENAM/630-QS01.G-007
This displays only one part of a multi-component CMC.
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in ng/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
organic solution
|
PCB 105 |
90
to 1000
|
7
to 1
|
Mechanism(s) for measurement service delivery:
Analytical service
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-QS03.003
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in %
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
1-pentanol
|
1-pentanol |
98
to 100
|
0.3
to 1
|
99.24
|
0.1
|
Mechanism(s) for measurement service delivery:
Analytical service, DMR-165 x
Uncertainty range convention 1. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-C014-013
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount-of-substance
in cmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
synthetic natural gas
|
methane |
70
to 98
|
0.4
to 0.7
|
Mechanism(s) for measurement service delivery:
MRTC-Program and analytical services
Internal NMI service identifier: CENAM/630-QS01.G-007
This displays only one part of a multi-component CMC.
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in mg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in mg/g
|
Mass fraction
in mg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in mg/g
|
|
calcium carbonate
|
total aluminum as aluminum oxide |
3.2
to 24.3
|
0.3
to 0.7
|
3.48
to 22.1
|
0.27
to 0.7
|
Mechanism(s) for measurement service delivery:
DMR 59a, DMR 64a
Uncertainty convention 1.
Internal NMI service identifier: CENAM/610-007
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/kg
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
fresh water
|
zinc |
40
to 1000
|
2
to 4
|
Mechanism(s) for measurement service delivery:
Value-assignment through MRTC program
Approved on 27 March 2013. Uncertainty convention 1.
Internal NMI service identifier: CENAM/620-Q008-24
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in ng/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
organic solution
|
PCB 153 |
90
to 1000
|
4
to 1
|
Mechanism(s) for measurement service delivery:
Analytical service
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-QS03.004
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in %
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
1-butanol
|
1-butanol |
98
to 100
|
0.3
to 1
|
99.79
|
0.1
|
Mechanism(s) for measurement service delivery:
Analytical service, DMR-165 x
Uncertainty range convention 1. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-C014-014
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in %
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
copper alloy
|
nickel |
0.05
to 0.2
|
7.5
to 4.5
|
Mechanism(s) for measurement service delivery:
Value-assignment through MRTC program
Approved on 19 July 2010. Uncertainty convention 2.
Internal NMI service identifier: CENAM/620-C002-21
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
fresh water
|
calcium |
5
to 25
|
1.8
to 3
|
Mechanism(s) for measurement service delivery:
Value-assignment through CENAM Traceable Reference Materials (MRTC)
Approved on 27 March 2013. Uncertainty convention 1.
Internal NMI service identifier: CENAM/620-Q018-005
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in ng/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
organic solution
|
PCB 170 |
90
to 1000
|
3
to 1
|
Mechanism(s) for measurement service delivery:
Analytical service
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-QS03.005
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in %
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
2-pentanol
|
2-pentanol |
98
to 100
|
0.3
to 1
|
99.76
|
0.1
|
Mechanism(s) for measurement service delivery:
Analytical service, DMR 174b
Uncertainty range convention 1. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-C014-015
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in mg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in mg/g
|
Mass fraction
in mg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in mg/g
|
|
calcium carbonate
|
total iron as iron (III) oxide |
1.3
to 1.7
|
0.1
|
1.51
|
0.06
|
Mechanism(s) for measurement service delivery:
DMR 59a
Internal NMI service identifier: CENAM/610-008
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in %
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
copper alloy
|
tin |
0.03
to 0.3
|
7
to 3
|
Mechanism(s) for measurement service delivery:
Value-assignment through MRTC program
Approved on 19 July 2010. Uncertainty convention 2.
Internal NMI service identifier: CENAM/620-Q008-20
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in µg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in µg/g
|
|
organic solution
|
phenanthrene |
3
to 15
|
3
to 1
|
8.06
to 103.1
|
0.16
to 1.9
|
Mechanism(s) for measurement service delivery:
DMR-275a, DMR-276a
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-Q023-001
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in µg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in µg/g
|
Mass fraction
in µg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in µg/g
|
|
calcium carbonate
|
total titanium as titanium (IV) oxide |
100
to 1050
|
10
to 40
|
140
to 910
|
10
to 40
|
Mechanism(s) for measurement service delivery:
DMR 59a, DMR 64a
Uncertainty convention 1.
Internal NMI service identifier: CENAM/610-009
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in %
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
glucose
|
glucose |
98
to 100
|
0.1
to 0.6
|
99.01
|
0.14
|
Mechanism(s) for measurement service delivery:
Analytical service, DMR-50, DMR-51, DMR 190a
Uncertainty range convention 1. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-C014-016
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in µg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in µg/g
|
|
organic solution
|
fluoranthene |
3
to 15
|
3
to 1
|
6.670
to 102.0
|
0.077
to 2.1
|
Mechanism(s) for measurement service delivery:
DMR-275a, DMR-276a
Uncertainty convention 2. Approved on 03 November 2006.
Internal NMI service identifier: CENAM/630-Q023-002
|