Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (277)
PHYSICS
Sound in air
Photometry
AC voltage, current, and power (15)
DC voltage, current, and resistance (3)
Density (20)
Dimensional metrology (20)
Fibre optics (3)
Fluid flow (16)
Force (15)
Frequency (5)
Impedance up to the MHz range (16)
Laser frequencies (2)
Mass, mass standards (28)
Other DC and low frequency measurements (1)
Pressure (18)
Properties of detectors and sources (8)
Properties of materials (4)
Radio frequency measurements (52)
Sound in water (1)
Temperature (15)
Time scale difference (4)
Torque, Viscosity, Hardness and Gravity (15)
Vibration (16)
GEOGRAPHIC LOCATION
SIM (277)
Mexico (277)
Result of the search
Your query 'cenam' produced 277 results New search
[<< Prev] 5  6  7 [Next >>]

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Mass and related quantities for Mexico (.PDF file)
Mass. Weight, 500 g
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.030
Subdivision
Temperature: 20 °C
Humidity: 40 % to 60 %
Pressure: 81 kPa
Approved on 04 December 2011
Internal NMI service identifier: CENAM/730-F008-C064-CC
 
Mass. Weight, 1 kg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.030
Subdivision
Temperature: 20 °C
Humidity: 40 % to 60 %
Pressure: 81 kPa
Approved on 04 December 2011
Internal NMI service identifier: CENAM/730-F008-C064-CC
 
Mass. Weight, 2 kg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.17
Subdivision
Temperature: 20 °C
Humidity: 40 % to 60 %
Pressure: 81 kPa
Approved on 04 December 2011
Internal NMI service identifier: CENAM/730-F008-C064-CC
 
Mass. Weight, 5 kg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 0.80
Subdivision
Temperature: 20 °C
Humidity: 40 % to 60 %
Pressure: 81 kPa
Approved on 04 December 2011
Internal NMI service identifier: CENAM/730-F008-C066-CC
 
Mass. Weight, 10 kg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 1.52
Subdivision
Temperature: 20 °C
Humidity: 40 % to 60 %
Pressure: 81 kPa
Approved on 04 December 2011
Internal NMI service identifier: CENAM/730-F005-C068-CC
 
Mass. Weight, 20 kg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 3.0
Direct comparison
Temperature: 20 °C
Humidity: 40 % to 60 %
Pressure: 81 kPa
Approved on 04 December 2011
Internal NMI service identifier: CENAM/730-F005-C105-CC
 
Mass. Weight, 50 kg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 7.0
Direct comparison
Temperature: 20 °C
Humidity: 40 % to 60 %
Pressure: 81 kPa
Approved on 04 December 2011
Internal NMI service identifier: CENAM/730-F005-C108-CC
 
Mass. Weight, 100 kg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 120
Direct comparison
Temperature: 20 °C
Humidity: 40 % to 60 %
Pressure: 81 kPa
Approved on 04 December 2011
Internal NMI service identifier: CENAM/730-H008-C078
 
Mass. Weight, 200 kg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 300
Direct comparison
Temperature: 20 °C
Humidity: 40 % to 60 %
Pressure: 81 kPa
Approved on 04 December 2011
Internal NMI service identifier: CENAM/730-H008-C078
 
Mass. Weight, 500 kg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 800
Direct comparison
Temperature: 20 °C
Humidity: 40 % to 60 %
Pressure: 81 kPa
Approved on 04 December 2011
Internal NMI service identifier: CENAM/730-H008-C080
 
Mass. Weight, 1000 kg
Absolute expanded uncertainty (k = 2, level of confidence 95%) in mg: 3000
Direct comparison
Temperature: 20 °C
Humidity: 40 % to 60 %
Pressure: 81 kPa
Approved on 04 December 2011
Internal NMI service identifier: CENAM/730-H008-C081
 
Volume of liquid. Volumetric test measure (micro-pipette), 0.01 cm3 to 1 cm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV9
 
Volume of liquid. Volumetric test measure (pipette, burette, flask), 1 cm3 to 10 cm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.05
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV10
 
Volume of liquid. Volumetric test measure (pipette, burette, flask), 10 cm3 to 2000 cm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.01
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV11
 
Volume of liquid. Volumetric test measure (pycnometer), 10 cm3 to 100 cm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.004
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV12
 
Volume of liquid. Volumetric test measure (graduated neck type), 2 dm3 to 50 dm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.015
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV13
 
Volume of liquid. Volumetric test measure (overflow type pipette), 5 dm3 to 50 dm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.005
Gravimetric determination
Temperature: 19 °C to 21 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV14
 
Volume of liquid. Volumetric test measure (graduated neck type), 50 dm3 to 3000 dm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.02
Volumetric transfer
Temperature: 18 °C to 26 °C
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV15
 
Volume of liquid. Volume quantity meter, 50 dm3 to 3000 dm3
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.06
Turbine and positive displacement meter
Temperature: 18 °C to 26 °C
Kinematic viscosity: 0.5 mm2/s to 5 mm2/s
Flow: < 50 dm3/s
Approved on 12 March 2007
Internal NMI service identifier: CENAM/FV16
 
Kinematic viscosity. Newtonian liquids, 0.003 mm2/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.22
Capillary viscometer
Temperature: 20 °C
Uncertainty statement corresponds to a reference temperature of 20 °C
Approved on 22 June 2006
Internal NMI service identifier: CENAM/1