Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (41)
PHYSICS
DC voltage, current, and resistance (41)
DC voltage, DC voltage meters, intermediate values (6)
DC resistance, DC resistance standards and sources, intermediate values (6)
DC resistance, DC resistance standards and sources, high values (6)
DC current, DC current sources, intermediate values (5)
DC current, DC current meters, intermediate values (5)
DC resistance, DC resistance meters, intermediate values (4)
DC voltage, DC voltage sources, low value ranges (3)
DC voltage, DC voltage sources, intermediate values (2)
DC resistance, DC resistance meters, high values (2)
DC resistance, DC resistance meters, low values (1)
DC current, DC current sources, low values (1)
DC resistance, DC resistance standards and sources, low values
DC current, DC current meters, low values
GEOGRAPHIC LOCATION
SIM (41)
Costa Rica (41)
Result of the search
Your query 'Costa Rica' produced 41 results New search
[Prev] 2  3

 
Costa Rica, ICE-LMVE (Instituto Costarricense de Electricidad, Laboratorio Metrológico de Variables Eléctricas)
Complete CMCs in Electricity and Magnetism for Costa Rica (.PDF file)
DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, 20 M to 200 M
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 173
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21303
 
DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, 0.2 G to 2 G
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 231
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21304
 
DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, 2 G to 20 G
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 693
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21305
 
DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, 20 G to 200 G
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 924
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/21306
 
DC resistance, DC resistance meters, low values. Multimeter, 1
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 97
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/22101
 
DC resistance, DC resistance meters, intermediate values. Teraohmmeter, 10 M
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 286
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/22202
 
DC resistance, DC resistance meters, intermediate values. Teraohmmeter, 100 M
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 174
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/22203
 
DC resistance, DC resistance meters, intermediate values. Teraohmmeter, 1 G
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 235
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/22204
 
DC resistance, DC resistance meters, high values. Teraohmmeter, 10 G
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 694
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/22301
 
DC resistance, DC resistance meters, high values. Teraohmmeter, 100 G
Relative expanded uncertainty (k = 2, level of confidence 95%) in µ/: 929
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/22302
 
DC current, DC current sources, low values. Multifunction calibrator, current generator, 0.01 mA to 0.1 mA
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 26 to 82
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/31101
 
DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, > 0.1 mA to 1 mA
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 23 to 59
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/31201
 
DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, 1 mA to 10 mA
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 23 to 59
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/31202
 
DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, 10 mA to 100 mA
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 35 to 70
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/31203
 
DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, 0.1 A to 1 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 97 to 167
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/31204
 
DC current, DC current sources, intermediate values. Multifunction calibrator, current generator, 1 A to 10 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 235 to 418
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/31205
 
DC current, DC current meters, intermediate values. Multimeter, > 0.1 mA to 1 mA
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 43 to 107
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/32201
 
DC current, DC current meters, intermediate values. Multimeter, 1 mA to 10 mA
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 40 to 77
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/32202
 
DC current, DC current meters, intermediate values. Multimeter, 10 mA to 100 mA
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 53 to 117
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/32203
 
DC current, DC current meters, intermediate values. Multimeter, 0.1 A to 1 A
Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 94 to 204
Direct comparison
Approved on 23 March 2010
Internal NMI service identifier: ICE-LMVE/32204