Refine your search |
|
CMC AREA |
|
|
|
|
CHEMICAL MATERIAL |
|
|
|
|
CHEMICAL ANALYTE |
|
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
particulates
|
benzo(a)pyrene |
1
to 15
|
4
to 13
|
Mechanism(s) for measurement service delivery:
Value-assignment to the PT samples
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-037
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
particulates
|
benzo(ghi)perylene |
1
to 15
|
4
to 6
|
Mechanism(s) for measurement service delivery:
Value-assignment to the PT samples
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-038
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
particulates
|
naphthalene |
1
to 15
|
4
to 6
|
Mechanism(s) for measurement service delivery:
Value-assignment to the PT samples
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-039
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
particulates
|
acenaphthylene |
1
to 15
|
4
to 6
|
Mechanism(s) for measurement service delivery:
Value-assignment to the PT samples
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-040
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
particulates
|
acenaphthene |
1
to 15
|
4
to 6
|
Mechanism(s) for measurement service delivery:
Value-assignment to the PT samples
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-041
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
particulates
|
fluorene |
1
to 15
|
4
to 6
|
Mechanism(s) for measurement service delivery:
Value-assignment to the PT samples
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-042
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
particulates
|
anthracene |
1
to 15
|
4
to 6
|
Mechanism(s) for measurement service delivery:
Value-assignment to the PT samples
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-043
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
particulates
|
pyrene |
1
to 15
|
4
to 6
|
Mechanism(s) for measurement service delivery:
Value-assignment to the PT samples
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-044
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
particulates
|
chrysene |
1
to 15
|
4
to 6
|
Mechanism(s) for measurement service delivery:
Value-assignment to the PT samples
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-045
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
particulates
|
benzo(a)anthracene |
1
to 15
|
4
to 15
|
Mechanism(s) for measurement service delivery:
Value-assignment to the PT samples
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-046
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
particulates
|
benzo (b) fluoranthene |
1
to 15
|
4
to 11
|
Mechanism(s) for measurement service delivery:
Value-assignment to the PT samples
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-047
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
particulates
|
benzo (k) fluoranthene |
1
to 15
|
4
to 11
|
Mechanism(s) for measurement service delivery:
Value-assignment to the PT samples
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-048
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
particulates
|
indeno (1,2,3-c,d) pyrene |
1
to 15
|
4
to 11
|
Mechanism(s) for measurement service delivery:
Value-assignment to the PT samples
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-049
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
particulates
|
dibenz (a,h) anthracene |
1
to 15
|
4
to 11
|
Mechanism(s) for measurement service delivery:
Value-assignment to the PT samples
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-050
|