Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (398)
CMCs Chemistry (23)
PHYSICS
Mass, mass standards
AC voltage, current, and power (254)
Dimensional metrology (32)
DC voltage, current, and resistance (31)
Impedance up to the MHz range (28)
Sound in air (18)
Pressure (11)
Temperature (11)
Properties of detectors and sources (5)
Frequency (5)
Laser frequencies (2)
Time interval (1)
CHEMICAL MATERIAL >
rice and rice flour (4)
soybean and soybean powder (4)
cereal and cereal products (4)
drinking water, fresh water (4)
aqueous buffer solution (3)
CHEMICAL ANALYTE >
carbon monoxide
cadmium (5)
calcium (4)
zinc (3)
pH (3)
copper (3)
GEOGRAPHIC LOCATION
APMP (421)
Thailand (421)
Result of the search
Your query 'NIMT' produced 421 results New search
[<< Prev] 6  7  8 [Next >>]

 
Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Electricity and Magnetism for Thailand (.PDF file)
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 20 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 61
AC-DC voltage transfer
Frequency: 400 Hz to 30 kHz
Internal NMI service identifier: NIMT/69
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 20 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 61
AC-DC voltage transfer
Frequency: 50 kHz to 70 kHz
Internal NMI service identifier: NIMT/70
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 20 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 71
AC-DC voltage transfer
Frequency: 100 kHz
Internal NMI service identifier: NIMT/71
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 20 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 140
AC-DC voltage transfer
Frequency: 200 kHz to 500 kHz
Internal NMI service identifier: NIMT/72
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 20 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 200
AC-DC voltage transfer
Frequency: 700 kHz to 1 MHz
Internal NMI service identifier: NIMT/73
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 60 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 66
AC-DC voltage transfer
Frequency: 10 Hz to 20 Hz
Internal NMI service identifier: NIMT/74
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 60 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 47
AC-DC voltage transfer
Frequency: 30 Hz to 300 Hz
Internal NMI service identifier: NIMT/75
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 60 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 47
AC-DC voltage transfer
Frequency: 400 Hz to 30 kHz
Internal NMI service identifier: NIMT/76
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 60 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 47
AC-DC voltage transfer
Frequency: 50 kHz to 70 kHz
Internal NMI service identifier: NIMT/77
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 60 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 52
AC-DC voltage transfer
Frequency: 100 kHz
Internal NMI service identifier: NIMT/78
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 60 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 100
AC-DC voltage transfer
Frequency: 200 kHz to 500 kHz
Internal NMI service identifier: NIMT/79
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 60 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 150
AC-DC voltage transfer
Frequency: 700 kHz to 1 MHz
Internal NMI service identifier: NIMT/80
 
AC voltage up to 1000 V: sources. Multifunction calibrator, 300 mV to 700 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 21
AC-DC voltage transfer
Voltage: 300 mV to 500 mV, 600 mV, 700 mV
Frequency: 400 Hz to 30 kHz
Internal NMI service identifier: NIMT/161
 
AC voltage up to 1000 V: sources. Multifunction calibrator, 300 mV to 700 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 21
AC-DC voltage transfer
Voltage: 300 mV to 500 mV, 600 mV, 700 mV
Frequency: 50 kHz to 70 kHz
Internal NMI service identifier: NIMT/162
 
AC voltage up to 1000 V: sources. Multifunction calibrator, 300 mV to 700 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 31
AC-DC voltage transfer
Voltage: 300 mV to 500 mV, 600 mV, 700 mV
Frequency: 100 kHz
Internal NMI service identifier: NIMT/163
 
AC voltage up to 1000 V: sources. Multifunction calibrator, 300 mV to 700 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 230
AC-DC voltage transfer
Voltage: 300 mV to 500 mV, 600 mV, 700 mV
Frequency: 200 kHz to 500 kHz
Internal NMI service identifier: NIMT/164
 
AC voltage up to 1000 V: sources. Multifunction calibrator, 300 mV to 700 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 230
AC-DC voltage transfer
Voltage: 300 mV to 500 mV, 600 mV, 700 mV
Frequency: 700 kHz to 1 MHz
Internal NMI service identifier: NIMT/165
 
AC voltage up to 1000 V: sources. Multifunction calibrator, 1 V to 7 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 20
AC-DC voltage transfer
Voltage: 1 V, 2 V, 3 V, 4 V, 5 V, 6 V, 7 V
Frequency: 10 Hz to 20 Hz
Internal NMI service identifier: NIMT/166
 
AC voltage up to 1000 V: sources. Multifunction calibrator, 1 V to 7 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 20
AC-DC voltage transfer
Voltage: 1 V, 2 V, 3 V, 4 V, 5 V, 6 V, 7 V
Frequency: 30 Hz to 300 Hz
Internal NMI service identifier: NIMT/167
 
AC voltage up to 1000 V: sources. Multifunction calibrator, 1 V to 7 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 20
AC-DC voltage transfer
Voltage: 1 V, 2 V, 3 V, 4 V, 5 V, 6 V, 7 V
Frequency: 400 Hz to 30 kHz
Internal NMI service identifier: NIMT/168