| | | Mexico, CENAM (Centro Nacional de Metrologia) | |  | Complete CMCs in Electricity and Magnetism for Mexico (.PDF file)
|  | |
| AC-DC voltage transfer: AC-DC transfer difference at low voltages (typically below or equal to 0.5 V). AC-DC transfer standard, 2 mV to 500 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 4 to 400 | | Direct comparison | | Frequency: 10 Hz to 1 MHz | | Approved on 28 April 2011 | | Internal NMI service identifier: CENAM/E010-003-01-a | | Uncertainty table |
| | | AC-DC voltage transfer: AC-DC transfer difference at medium voltages (typically above 0.5 V to 5 V). AC-DC transfer standard, 1 V to 5 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 4 to 42 | | Direct comparison | | Frequency: 10 Hz to 1 MHz | | Approved on 28 April 2011 | | Internal NMI service identifier: CENAM/E010-003-02-a | | Uncertainty table |
| | | AC-DC voltage transfer: AC-DC transfer difference at higher voltages (typically above 5 V). AC-DC transfer standard, 10 V to 1000 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 6 to 103 | | Direct comparison | | Frequency: 10 Hz to 1 MHz | | Approved on 28 April 2011 | | Internal NMI service identifier: CENAM/E010-003-03-a | | Uncertainty table |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 0.002 V to 1000 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 12 to 600 | | Comparison vs AC-DC transfer standard | | Frequency: 10 Hz to 1 MHz | | Approved on 28 April 2011 | | Internal NMI service identifier: CENAM/E010-001-01-a | | Uncertainty table |
| | | AC voltage up to 1000 V: meters. Multimeter, 0.002 V to 1000 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 12 to 600 | | Direct comparison | | Frequency: 10 Hz to 1 MHz | | Approved on 28 April 2011 | | Internal NMI service identifier: CENAM/E010-001-02-a | | Uncertainty table |
| | | AC-DC current transfer: AC-DC transfer difference. Thermal converter plus shunt, 0.001 A to 20 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 30 to 115 | | Direct comparison | | Frequency: 40 Hz to 5 kHz | | Approved on 28 April 2011 | | Internal NMI service identifier: CENAM/E010-006-01-a | | Uncertainty table |
| | | AC current up to 100 A: meters. Multimeter, 0.001 A to 20 A | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 35 to 800 | | Direct measurement using a characterized calibrator | | Frequency: 40 Hz to 5 kHz | | Approved on 28 April 2011 | | Internal NMI service identifier: CENAM/E003-002-52-a | | Uncertainty table |
| | | AC power and energy: single phase (frequency <= 400 Hz, reactive power). VAR meter, 0 var to 6E+04 var | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µvar/VA: 20 to 30 | | Direct comparison | | Voltage: 120 V, 240 V, 480 V, 600 V | | Current: 0.25 A to 100 A | | Power factor: 1 to 0, inductive or capacitive | | Frequency: 60 Hz | | Approved on 05 January 2012 | | Internal NMI service identifier: CENAM/E012-001-02 | | Uncertainty table |
| | | AC power and energy: single phase (frequency <= 400 Hz, apparent power). VA meter, 30 VA to 6E+04 VA | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µVA/VA: 20 to 30 | | Direct comparison | | Voltage: 120 V, 240 V, 480 V, 600 V | | Current: 0.25 A to 100 A | | Power factor: 1 to 0, inductive or capacitive | | Frequency: 60 Hz | | Approved on 05 January 2012 | | Internal NMI service identifier: CENAM/E012-001-03 | | Uncertainty table |
| | | AC power and energy: single phase (frequency <= 400 Hz, active energy). Watt-hour meter, 0 J to 7.2E+06 J | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µJ/VAs: 20 to 30 | | Direct comparison | | Voltage: 120 V, 240 V, 480 V, 600 V | | Current: 0.25 A to 100 A | | Power factor: 1 to 0, inductive or capacitive | | Frequency: 60 Hz | | Measurement time: 120 s | | Approved on 05 January 2012 | | Internal NMI service identifier: CENAM/E012-001-04 | | Uncertainty table |
| | | AC power and energy: single phase (frequency <= 400 Hz, reactive energy). VAR-hour meter, 0 vars to 7.2E+06 vars | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µvars/VAs: 20 to 30 | | Direct comparison | | Voltage: 120 V, 240 V, 480 V, 600 V | | Current: 0.25 A to 100 A | | Power factor: 1 to 0, inductive or capacitive | | Frequency: 60 Hz | | Measurement time: 120 s | | Approved on 05 January 2012 | | Internal NMI service identifier: CENAM/E012-001-05 | | Uncertainty table |
| | | AC power and energy: single phase (frequency <= 400 Hz, apparent energy). VA-hour meter, 3.6E+03 VAs to 7.2E+06 VAs | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µVAs/VAs: 20 to 30 | | Direct comparison | | Voltage: 120 V, 240 V, 480 V, 600 V | | Current: 0.25 A to 100 A | | Power factor: 1 to 0, inductive or capacitive | | Frequency: 60 Hz | | Measurement time: 120 s | | Approved on 05 January 2012 | | Internal NMI service identifier: CENAM/E012-001-06 | | Uncertainty table |
|