| | | Mexico, CENAM (Centro Nacional de Metrologia) | |  | Complete CMCs in Length for Mexico (.PDF file)
|  | |
| Diameter standards. External cylinder (plug): diameter, L, 0.005 m to 0.3 m | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in µm: (0.18 + 0.4L) | | 1-D stylus comparator, gauge substitution | | Approved on 14 June 2004 | | Internal NMI service identifier: CENAM/16 |
| | | Diameter standards. Internal cylinder (ring): diameter L, 0.005 m to 0.205 m | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in µm: (0.18 + 0.4L) | | 1-D stylus comparator, gauge substitution | | Maximal external size diameter: 300 mm | | Approved on 14 June 2004 | | Internal NMI service identifier: CENAM/17 |
| | | Diameter standards. External cylinder (pin or wire): diameter L, 0.1 mm to 5 mm | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in µm: (0.25 + 0.001L) | | 1-D stylus comparator, gauge substitution | | Approved on 14 June 2004 | | Internal NMI service identifier: CENAM/18 |
| | | Diameter standards. Ball or sphere: diameter L, 0.005 m to 0.065 m | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in µm: (0.18 + 0.4L) | | 1-D stylus comparator, gauge substitution | | Approved on 14 June 2004 | | Internal NMI service identifier: CENAM/19 |
| | | Angle artefacts. Angle block: included angle, 1 ° (or ', or ") to 45 ° (or ', or ") | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in ": 0.3 | | Index table and autocollimator, full closure | | Specific angle sizes: 1, 2, 3, 5, 10, 15, 20, 30, 45 in °, or ', or " | | Approved on 14 June 2004 | | Internal NMI service identifier: CENAM/28 |
| | | CMM artefacts. Ball bar: ball spacing L, 10 mm to 1100 mm | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in µm: (0.4 + 0.6E-03L) | | CMM and stylus, with gauge substitution | | Approved on 14 June 2004 | | Internal NMI service identifier: CENAM/36 |
| | | CMM artefacts. Ball and bore plates, L, 10 mm to 650 mm | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in µm: (0.6 + 0.9E-03L) | | CMM and stylus, with gauge substitution and reversal methods | | Approved on 14 June 2004 | | Internal NMI service identifier: CENAM/37 |
|