Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (30)
PHYSICS
Dimensional metrology (30)
End standards (9)
Diameter standards (4)
Surface texture (3)
Flatness standard (3)
Roundness standards (2)
2-D, 3-D instruments (2)
Surface texture standards (2)
Line standard (2)
Angle artefacts (1)
CMM artefacts (1)
Angle instrument (1)
Angle by circle divider
CHEMICAL ANALYTE
carbon monoxide
GEOGRAPHIC LOCATION
APMP (30)
Thailand (30)
Result of the search
Your query 'NIMT' produced 30 results New search
1  2

 
Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Length for Thailand (.PDF file)
Surface texture. Roughness standard, ISO 5436-1 type C, D: Ra (ISO 4287), 0.025 µm to 32 µm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in nm: Q[10, 12Ra], Ra in µm, values range from 10 nm to 3.8E+02 nm
Stylus instrument
Ra (ISO 4287): ISO 4287, ISO 4288, ISO 11562
Approved on 28 April 2010
Internal NMI service identifier: NIMT/08060-10601
 
Surface texture. Roughness standard, ISO 5436-1 type C, D: Rz (ISO 4287), 0.025 µm to 32 µm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in nm: Q[18, 17Rz], Rz in µm, values range from 18 nm to 5.4E+02 nm
Stylus instrument
Rz (ISO 4287): ISO 4287, ISO 4288, ISO 11562
Approved on 28 April 2010
Internal NMI service identifier: NIMT/08060-10601
 
2-D, 3-D instruments. CMM: error of indicated [size; location; shape], up to 1200 x 1000 x 700 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µm: Q[0.52, 1.4E-03L], L in mm
Comparison with gauge blocks
CMM size: < 1200 mm x 1000 mm x 700 mm
Approved on 26 January 2012
 
2-D, 3-D instruments. CMM: error of indicated [size; location; shape], up to 1200 x 1000 x 700 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µm: Q[0.52, 2.0E-03L], L in mm
Comparison with step gauges
CMM size: < 1200 mm x 1000 mm x 700 mm
Approved on 26 January 2012
 
End standards. Step gauge: face spacing, up to 1020 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µm: Q[0.26, 1.4E-03L], L in mm
CMM with laser interferometer
Step gauge size: < 1020 mm
Approved on 26 January 2012
 
End standards. Caliper checker: face spacing, up to 1020 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µm: Q[0.30, 2.7E-03L], L in mm
CMM with laser interferometer
Caliper checker size: < 1020 mm
Approved on 26 January 2012
 
CMM artefacts. Ball plate: 2D center coordinates, up to 620 x 620 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µm: Q[0.27, 1.9E-03L], L in mm
CMM with laser interferometer using swing round method
Ball plate size: < 620 mm x 620 mm
Approved on 26 January 2012
 
Surface texture standards. Depth standard, (ISO 5436-1, type A), depth d, 0.01 µm to 10 µm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in nm: Q[2.4, 5.4d], d in µm
Interference microscope and stylus instrument (for pre-measurement)
Groove depth: ISO 5436-1
Approved on 26 January 2012
 
Surface texture standards. Depth standard, (ISO 5436-1, type A), depth d, 0.3 µm to 50 µm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in nm: Q[75, 7.3d], d in µm
Non-contact optical profiler
Groove depth: ISO 5436-1
Approved on 26 January 2012
 
Line standard. Precision line scale: line spacing, up to 250 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in nm: Q[41, 100.0E-03L], L in mm
Line scale interferometer
Glass scale: low coefficient of thermal expansion (8E-08 K-1)
Approved on 26 January 2012
 
Line standard. Precision line scale: line spacing, up to 1000 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µm: Q[0.11, 2.9E-03L], L in mm
Line scale interferometer
Glass scale: working standard
Approved on 26 January 2012
 
End standards. Gauge block: central length L, 0.5 mm to 125 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in nm: Q[28, 0.47L], L in mm, values range from 28 nm to 65 nm
Interferometry exact fractions
Material: steel
Approved on 28 April 2010
Internal NMI service identifier: NIMT/08020-10101
 
End standards. Gauge block: central length L, 0.5 mm to 125 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in nm: Q[30, 0.39L], L in mm, values range from 30 nm to 57 nm
Interferometry exact fractions
Material: ceramic
Approved on 28 April 2010
Internal NMI service identifier: NIMT/08020-10101
 
End standards. Gauge block: central length L, 0.5 mm to 125 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in nm: Q[28, 0.22L], L in mm, values range from 28 nm to 39 nm
Interferometry exact fractions
Material: tungsten carbide
Approved on 28 April 2010
Internal NMI service identifier: NIMT/08020-10101
 
End standards. Gauge block: central length L, 0.5 mm to 125 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in nm: Q[28, 0.36L], L in mm, values range from 28 nm to 53 nm
Interferometry exact fractions
Material: chromium carbide
Approved on 28 April 2010
Internal NMI service identifier: NIMT/08020-10101
 
End standards. Gauge block: central length L, 0.5 mm to 125 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in nm: Q[50, 0.50L], L in mm, values range from 50 nm to 1.2E+02 nm
Mechanical comparison
Material: steel, tungsten carbide and chromium carbide
Approved on 28 April 2010
Internal NMI service identifier: NIMT/08020-10301
 
End standards. Gauge block: central length L, 0.5 mm to 125 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in nm: Q[70, 0.50L], L in mm, values range from 70 nm to 1.4E+02 nm
Mechanical comparison
Material: ceramic
Approved on 28 April 2010
Internal NMI service identifier: NIMT/08020-10301
 
End standards. Gauge block: central length L, 150 mm to 1000 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in nm: Q[50, 0.80L], L in mm, values range from 1.3E+02 nm to 8.5E+02 nm
Mechanical comparison
Material: steel
Approved on 28 April 2010
Internal NMI service identifier: NIMT/08020-10501, 08020-10502, 08020-10503
 
Diameter standards. External cylinder (plain plug gauge): diameter, 0.1 mm to 1 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µm: 0.24
1-d comparator and 2 contacting probes
Approved on 28 April 2010
Internal NMI service identifier: NIMT/08040-10501
 
Diameter standards. External cylinder (plain plug gauge): diameter D, 1 mm to 100 mm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in µm: Q[0.23, 1.4E-03D], D in mm, values range from 0.23 µm to 0.27 µm
1-d comparator and 2 contacting probes
Approved on 28 April 2010
Internal NMI service identifier: NIMT/08040-10502