Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Electricity and Magnetism for Mexico (.PDF file)
Capacitance: meters. Capacitance bridge, LCR meter (capacitance), 0.001 nF to 1000 nF
Relative expanded uncertainty (k = 2, level of confidence 95%) in µF/F: 0.5 to 40
Direct measurement
Frequency: 1 kHz
Voltage: 1 mV to 50 V
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-004B
Uncertainty table
 
Inductance: meters. LCR meter (inductance), 0.1 mH to 10000 mH
Relative expanded uncertainty (k = 2, level of confidence 95%) in mH/H: 0.05 to 0.63
Direct measurement
Frequency: 1 kHz
Current: 10 µA to 30 mA
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-004B
Uncertainty table
 
Inductance: self inductance, high values. Fixed inductor, 10 H
Relative expanded uncertainty (k = 2, level of confidence 95%) in mH/H: 0.16
Substitution using an LCR meter
Frequency: 1 kHz
Current: 10 µA
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-010-06
 
Capacitance: dielectric capacitors. Fixed capacitor (mica), 1 nF
Relative expanded uncertainty (k = 2, level of confidence 95%) in µF/F: 10
Substitution using an 8-digits capacitance meter
Frequency: 1 kHz
Voltage: 0.75 V
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-004-01
 
Capacitance: dielectric capacitors. Fixed capacitor (mica), 10 nF
Relative expanded uncertainty (k = 2, level of confidence 95%) in µF/F: 35
Substitution using an 8-digits capacitance meter
Frequency: 1 kHz
Voltage: 100 mV
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-004-02
 
Capacitance: dielectric capacitors. Fixed capacitor (mica), 100 nF
Relative expanded uncertainty (k = 2, level of confidence 95%) in µF/F: 40
Substitution using an 8-digits capacitance meter
Frequency: 1 kHz
Voltage: 10 mV
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-004-03
 
Capacitance: dielectric capacitors. Fixed capacitor (mica), 1 µF
Relative expanded uncertainty (k = 2, level of confidence 95%) in µF/F: 45
Substitution using an 8-digits capacitance meter
Frequency: 1 kHz
Voltage: 1 mV
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-004-04
 
Inductance: self inductance, low values. Fixed inductor, 100 µH
Relative expanded uncertainty (k = 2, level of confidence 95%) in mH/H: 0.60
Substitution using an LCR meter
Frequency: 1 kHz
Current: 30 mA
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E009-010-01