Refine your search |
|
CMC AREA |
|
|
|
|
PHYSICS |
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
| | | Thailand, NIMT (National Institute of Metrology (Thailand)) | |  | Complete CMCs in Acoustics, Ultrasound, Vibration for Thailand (.PDF file)
|  | |
| Pressure sensitivity level. Measurement microphone type LS1P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.05 | | IEC 61094-2:1992 | | Frequency: 20 Hz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11101 |
| | | Pressure sensitivity level. Measurement microphone type LS1P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.04 | | IEC 61094-2:1992 | | Frequency: 31.5 Hz to 4 kHz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11101 |
| | | Pressure sensitivity level. Measurement microphone type LS1P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.06 | | IEC 61094-2:1992 | | Frequency: 8 kHz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11101 |
| | | Pressure sensitivity level. Measurement microphone type LS1P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.07 | | IEC 61094-2:1992 | | Frequency: 10 kHz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11101 |
| | | Pressure sensitivity level. Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.10 | | IEC 61094-2:1992 | | Frequency: 20 Hz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11102 |
| | | Pressure sensitivity level. Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.06 | | IEC 61094-2:1992 | | Frequency: 31.5 Hz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11102 |
| | | Pressure sensitivity level. Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.04 | | IEC 61094-2:1992 | | Frequency: 63 Hz to 12.5 kHz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11102 |
| | | Pressure sensitivity level. Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.05 | | IEC 61094-2:1992 | | Frequency: 16 kHz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11102 |
| | | Pressure sensitivity level. Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.08 | | IEC 61094-2:1992 | | Frequency: 20 kHz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11102 |
| | | DC voltage sources: low value ranges (equal or below 10 V). DC voltage source, multifunction calibrator, voltage V, 0 V to 10 V | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in µV: (0.5 v + 2), v in V | | Compare against DC standard | | Internal NMI service identifier: NIMT/7 |
| | | DC voltage sources: intermediate values (higher than 10 V to 1100 V). DC voltage source, multifunction calibrator, voltage V, > 10 V to 100 V | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in µV: (0.5 v + 15), v in V | | Compare against DC standard | | Internal NMI service identifier: NIMT/8 |
| | | DC voltage sources: intermediate values (higher than 10 V to 1100 V). DC voltage source, multifunction calibrator, voltage V, > 100 V to 1000 V | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in µV: (0.8 v + 200), v in V | | Compare against DC standard | | Internal NMI service identifier: NIMT/9 |
| | | DC voltage sources: single values. Solid state voltage standard, 10 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 0.4 | | Compare against DC standard | | Internal NMI service identifier: NIMT/1 |
| | | DC voltage sources: single values. Solid state voltage standard, standard cell, 1.018 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 0.9 | | Compare against DC standard | | Internal NMI service identifier: NIMT/2 |
| | | DC voltage sources: low values (equal or below 10 V). DC voltage source, multifunction calibrator, 100 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 5 | | Compare against DC standard | | Internal NMI service identifier: NIMT/3 |
| | | DC voltage sources: low values (equal or below 10 V). DC voltage source, multifunction calibrator, 1 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 0.6 | | Compare against DC standard | | Internal NMI service identifier: NIMT/4 |
| | | DC voltage sources: intermediate values (higher than 10 V to 1100 V). DC voltage source, multifunction calibrator, 100 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 0.5 | | Compare against DC standard | | Internal NMI service identifier: NIMT/5 |
| | | DC voltage sources: intermediate values (higher than 10 V to 1100 V). DC voltage source, multifunction calibrator, 1000 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 0.7 | | Compare against DC standard | | Internal NMI service identifier: NIMT/6 |
| | DC resistance sources: low values (equal or below 1 ohm). Fixed resistor, 0.001  | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 2.8 | | DCC bridge & range extender | | Current: 10 A to 100 A | | Oil bath temperature: 23 °C | | Internal NMI service identifier: NIMT/10 |
| | DC resistance sources: low values (equal or below 1 ohm). Fixed resistor, 0.01  | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 2.3 | | DCC bridge & range extender | | Current: 1 A to 10 A | | Oil bath temperature: 23 °C | | Internal NMI service identifier: NIMT/11 |
|