Refine your search |
|
CMC AREA |
|
|
|
|
PHYSICS |
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
|
Your query 'Costa Rica' produced 75 results
|
New search
|
| | | Costa Rica, ICE-LMVE (Instituto Costarricense de Electricidad, Laboratorio Metrológico de Variables Eléctricas) | |  | Complete CMCs in Electricity and Magnetism for Costa Rica (.PDF file)
|  | |
DC resistance, DC resistance standards and sources, low values. Fixed resistor, resistance box, 0.1 to 1  | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 53 to 402 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21101 |
| | DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, > 1 to 10  | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 18 to 53 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21201 |
| | DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, 10 to 100  | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 16 to 50 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21202 |
| | DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, 100 to 1000  | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 10 to 14 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21203 |
| | DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, 1 k to 10 k | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 10 to 14 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21204 |
| | DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, 10 k to 100 k | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 10 to 14 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21205 |
| | DC resistance, DC resistance standards and sources, intermediate values. Fixed resistor, resistance box, 100 k to 1000 k | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 16 to 30 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21206 |
| | DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, > 1 M to 10 M | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 49 to 119 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21301 |
| | DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, 10 M to 100 M | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 398 to 468 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21302 |
| | DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, 20 M to 200 M | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 173 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21303 |
| | DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, 0.2 G to 2 G | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 231 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21304 |
| | DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, 2 G to 20 G | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 693 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21305 |
| | DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, 20 G to 200 G | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 924 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21306 |
| | DC resistance, DC resistance meters, low values. Multimeter, 1  | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 97 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/22101 |
| | DC resistance, DC resistance meters, intermediate values. Teraohmmeter, 10 M | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 286 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/22202 |
| | DC resistance, DC resistance meters, intermediate values. Teraohmmeter, 100 M | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 174 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/22203 |
| | DC resistance, DC resistance meters, intermediate values. Teraohmmeter, 1 G | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 235 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/22204 |
| | DC resistance, DC resistance meters, high values. Teraohmmeter, 10 G | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 694 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/22301 |
| | DC resistance, DC resistance meters, high values. Teraohmmeter, 100 G | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 929 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/22302 |
| | | DC current, DC current sources, low values. Multifunction calibrator, current generator, 0.01 mA to 0.1 mA | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µA/A: 26 to 82 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/31101 |
|