Refine your search |
|
CMC AREA |
|
|
|
|
PHYSICS |
|
|
|
|
CHEMICAL MATERIAL |
|
|
|
|
|
CHEMICAL ANALYTE |
|
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/kg
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
rice and rice flour
|
zinc |
10
to 80
|
3.0
to 3.5
|
Mechanism(s) for measurement service delivery:
Provision of reference values for PT schemes and reference material producer
Uncertainty convention 1. Approved on 06 September 2012. This CMC is relevant to both sub-categories "Nutritional constituents" and "Contaminants".
Internal NMI service identifier: NIMT/12020-60805
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/kg
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
soybean and soybean powder
|
zinc |
10
to 80
|
3.0
to 3.5
|
Mechanism(s) for measurement service delivery:
Provision of reference values for PT schemes and reference material producer
Uncertainty convention 1. Approved on 06 September 2012. This CMC is relevant to both sub-categories "Nutritional constituents" and "Contaminants".
Internal NMI service identifier: NIMT/12020-60806
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/kg
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
cereal and cereal products
|
zinc |
10
to 80
|
3.0
to 3.5
|
Mechanism(s) for measurement service delivery:
Provision of reference values for PT schemes and reference material producer
Uncertainty convention 1. Approved on 06 September 2012. This CMC is relevant to both sub-categories "Nutritional constituents" and "Contaminants".
Internal NMI service identifier: NIMT/12020-60804
| | | Thailand, NIMT (National Institute of Metrology (Thailand)) | |  | Complete CMCs in Acoustics, Ultrasound, Vibration for Thailand (.PDF file)
|  | |
| Pressure sensitivity level. Measurement microphone type LS1P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.05 | | IEC 61094-2:1992 | | Frequency: 20 Hz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11101 |
| | | Pressure sensitivity level. Measurement microphone type LS1P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.04 | | IEC 61094-2:1992 | | Frequency: 31.5 Hz to 4 kHz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11101 |
| | | Pressure sensitivity level. Measurement microphone type LS1P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.06 | | IEC 61094-2:1992 | | Frequency: 8 kHz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11101 |
| | | Pressure sensitivity level. Measurement microphone type LS1P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.07 | | IEC 61094-2:1992 | | Frequency: 10 kHz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11101 |
| | | Pressure sensitivity level. Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.10 | | IEC 61094-2:1992 | | Frequency: 20 Hz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11102 |
| | | Pressure sensitivity level. Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.06 | | IEC 61094-2:1992 | | Frequency: 31.5 Hz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11102 |
| | | Pressure sensitivity level. Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.04 | | IEC 61094-2:1992 | | Frequency: 63 Hz to 12.5 kHz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11102 |
| | | Pressure sensitivity level. Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.05 | | IEC 61094-2:1992 | | Frequency: 16 kHz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11102 |
| | | Pressure sensitivity level. Measurement microphone type LS2P. Measurand unit, dB (reference: 1 V/Pa) | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in dB (reference: 1 V/Pa): 0.08 | | IEC 61094-2:1992 | | Frequency: 20 kHz | | Approved on 11 January 2013 | | Internal NMI service identifier: NIMT/14010 - 11102 |
| | | DC voltage sources: low value ranges (equal or below 10 V). DC voltage source, multifunction calibrator, voltage V, 0 V to 10 V | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in µV: (0.5 v + 2), v in V | | Compare against DC standard | | Internal NMI service identifier: NIMT/7 |
| | | DC voltage sources: intermediate values (higher than 10 V to 1100 V). DC voltage source, multifunction calibrator, voltage V, > 10 V to 100 V | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in µV: (0.5 v + 15), v in V | | Compare against DC standard | | Internal NMI service identifier: NIMT/8 |
| | | DC voltage sources: intermediate values (higher than 10 V to 1100 V). DC voltage source, multifunction calibrator, voltage V, > 100 V to 1000 V | | Absolute expanded uncertainty (k = 2, level of confidence 95%) in µV: (0.8 v + 200), v in V | | Compare against DC standard | | Internal NMI service identifier: NIMT/9 |
| | | Inductance: self inductance and equivalent series resistance, low values (below 1 mH). Fixed inductor, 100 µH | | Relative expanded uncertainty (k = 2, level of confidence 95%) in mH/H: 0.35 | | Compare against reference standard | | Frequency: 1 kHz | | Internal NMI service identifier: NIMT/55 |
| | | AC-DC voltage transfer: AC-DC transfer difference at higher voltages (higher than 5 V). Thermal converters, AC-DC transfer standard, 7 V to 10 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 13 | | AC-DC voltage transfer | | Voltage: 7 V, 10 V | | Frequency: 50 kHz to 70 kHz | | Internal NMI service identifier: NIMT/105 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 300 mV to 700 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 23 | | AC-DC voltage transfer | | Voltage: 300 mV to 500 mV, 600 mV, 700 mV | | Frequency: 30 Hz to 300 Hz | | Internal NMI service identifier: NIMT/160 |
| | | AC voltage up to 1000 V: meters. AC voltmeter, multimeter, 100 mV to 200 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 38 | | AC-DC voltage transfer | | Voltage: 100 mV, 200 mV | | Frequency: 10 Hz to 20 Hz | | Internal NMI service identifier: NIMT/216 |
| | | AC voltage up to 1000 V: meters. AC voltmeter, multimeter, 100 mV to 200 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 25 | | AC-DC voltage transfer | | Voltage: 100 mV, 200 mV | | Frequency: 30 Hz to 300 Hz | | Internal NMI service identifier: NIMT/217 |
|