Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (261)
PHYSICS >
Sound in air
DC voltage, current, and resistance
Dimensional metrology
Radio frequency measurements (52)
Mass, mass standards (28)
Density (20)
Pressure (18)
Vibration (16)
Fluid flow (16)
Impedance up to the MHz range (16)
Torque, Viscosity, Hardness and Gravity (15)
Force (15)
AC voltage, current, and power (15)
Temperature (15)
Properties of detectors and sources (8)
CHEMICAL MATERIAL
particulates
CHEMICAL ANALYTE
zinc
GEOGRAPHIC LOCATION
SIM (261)
Mexico (261)
Result of the search
Your query 'cenam' produced 261 results New search
1  2  3 [Next >>]

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Length for Mexico (.PDF file)
Laser radiations. Stabilized laser of the mise en pratique: absolute frequency, 474 THz
Absolute expanded uncertainty (k = 2, level of confidence 95%) in kHz: 24
Optical beat frequency
Internal NMI service identifier: CENAM/1
 
Laser radiations. Other stabilized laser: vacuum wavelength , 633 nm
Absolute expanded uncertainty (k = 2, level of confidence 95%) in nm: 2E-09
Optical beat frequency
Internal NMI service identifier: CENAM/2
 
Charge sensitivity (phase shift). Accelerometer, 0 ° to 360 °
Absolute expanded uncertainty (k = 2, level of confidence 95%) in °: 2
Laser interferometry ISO 16063-11
Frequency: 50 Hz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F011-001
 
Voltage sensitivity (phase shift). Acceleration measuring chain, 0 ° to 360 °
Absolute expanded uncertainty (k = 2, level of confidence 95%) in °: 2
Laser interferometry ISO 16063-11
Frequency: 50 Hz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F011-001
 
Ultrasonic power. Ultrasonic source transducer, 0.01 W to 1 W
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 11
Radiation force balance IEC 1161
Frequency: 1 MHz to 10 MHz
Internal NMI service identifier: CENAM/510-F018-003
 
Charge sensitivity (magnitude). Accelerometer. Measurand unit, C/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1
Reciprocity ASA S2.2-1959 ISO-16063-1
Frequency: 100 Hz to 4 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F010-001
 
Charge sensitivity (magnitude). Accelerometer. Measurand unit, C/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.5
Laser interferometry ISO 16063-11
Frequency: 50 Hz to 1 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F011-001
 
Charge sensitivity (magnitude). Accelerometer. Measurand unit, C/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.8
Laser interferometry ISO 16063-11
Frequency: 1 kHz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F011-001
 
Charge sensitivity (magnitude). Accelerometer. Measurand unit, C/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 2
Laser interferometry ISO 16063-11
Frequency: 5 kHz to 8 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F011-001
 
Charge sensitivity (magnitude). Accelerometer. Measurand unit, C/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.2
Comparison, ISO 5347-3
Frequency: 50 Hz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F012-001
 
Voltage sensitivity (magnitude). Acceleration measuring chain. Measurand unit, V/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.5
Laser interferometry ISO 16063-11
Frequency: 50 Hz to 1 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F011-001
 
Voltage sensitivity (magnitude). Acceleration measuring chain. Measurand unit, V/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.2
Comparison, ISO 5347-3
Frequency: 50 Hz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F012-001
 
Voltage sensitivity (magnitude). Acceleration measuring chain. Measurand unit, V/(m/s2)
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.7
Comparison, ISO 5347-3
Frequency: 50 Hz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F012-015
 
Acceleration. Acceleration measuring instrument, 10 m/s2 to 100 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.5
Laser interferometry ISO 16063-11
Frequency: 50 Hz to 1 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F011-001
 
Acceleration. Acceleration measuring instrument, 10 m/s2 to 100 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 0.8
Laser interferometry ISO 16063-11
Frequency: 1 kHz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F011-001
 
Acceleration. Acceleration measuring instrument, 10 m/s2 to 50 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1.2
Comparison, ISO 5347-3
Frequency: 50 Hz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F019-001
 
Acceleration. Acceleration measuring instrument, 10 m/s2 to 50 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 2
Comparison, ISO 5347-3
Frequency: 50 Hz to 1 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-G'03-002
 
Acceleration. Calibrators, 10 m/s2 to 100 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 1
Comparison, ISO 5347-3
Frequency: 80 Hz to 160 Hz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F012-009
 
Acceleration. Calibrators, 10 m/s2 to 100 m/s2
Relative expanded uncertainty (k = 2, level of confidence 95%) in %: 2
Comparison, ISO 5347-3
Frequency: 50 Hz to 5 kHz
Sinusoidal excitation
Internal NMI service identifier: CENAM/510-F012-009
 
Temperature. Tungsten strip filament gas lamps, 1600 °C to 2200 °C
Absolute expanded uncertainty (k = 2, level of confidence 95%) in °C: 1.4 to 2.2
Radiance temperature determination as a function of filament current
Wavelength: 650 nm
Filament current
Approved on 29 June 2004
Internal NMI service identifier: CENAM/420-E008-003