Refine your search |
|
CMC AREA |
|
|
|
|
PHYSICS |
|
|
|
|
|
CHEMICAL MATERIAL |
|
|
|
|
|
CHEMICAL ANALYTE |
|
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
|
Your query 'cenam' produced 554 results
|
New search
|
| | | Mexico, CENAM (Centro Nacional de Metrologia) | |  | Complete CMCs in Electricity and Magnetism for Mexico (.PDF file)
|  | |
| Reflection coefficient s22: on coaxial phase (with magnitude of reflection coefficient below or equal to 0.1). 2-port coaxial device, -180 ° to 180 ° | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in °: 5.09 to 180 | | Vector automatic network analyzer | | Frequency: 10 GHz to 18 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -004-CC, -007-CC | | Uncertainty table |
| | | Reflection coefficient s22: on coaxial phase (with magnitude of reflection coefficient above or equal to 0.1). 2-port coaxial device, -180 ° to 180 ° | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in °: 1.79 to 2.22 | | Vector automatic network analyzer | | Frequency: 45 MHz to 2 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -004-CC, -007-CC | | Uncertainty table |
| | | Reflection coefficient s22: on coaxial phase (with magnitude of reflection coefficient above or equal to 0.1). 2-port coaxial device, -180 ° to 180 ° | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in °: 1.81 to 2.67 | | Vector automatic network analyzer | | Frequency: 2 GHz to 10 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -004-CC, -007-CC | | Uncertainty table |
| | | Reflection coefficient s22: on coaxial phase (with magnitude of reflection coefficient above or equal to 0.1). 2-port coaxial device, -180 ° to 180 ° | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in °: 3.56 to 5.18 | | Vector automatic network analyzer | | Frequency: 10 GHz to 18 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -004-CC, -007-CC | | Uncertainty table |
| | | Reflection coefficient: on coaxial magnitude. 1-port coaxial device, 0 to 1 | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%): 0.0040 to 0.0082 | | Vector automatic network analyzer | | Frequency: 45 MHz to 2 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -008-CC | | Uncertainty table |
| | | Reflection coefficient: on coaxial magnitude. 1-port coaxial device, 0 to 1 | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%): 0.0060 to 0.0128 | | Vector automatic network analyzer | | Frequency: 2 GHz to 10 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -008-CC | | Uncertainty table |
| | | Reflection coefficient: on coaxial magnitude. 1-port coaxial device, 0 to 1 | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%): 0.0112 to 0.0159 | | Vector automatic network analyzer | | Frequency: 10 GHz to 18 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -008-CC | | Uncertainty table |
| | | Reflection coefficient: on coaxial phase (with magnitude of reflection coefficient below or equal to 0.1). 1-port coaxial device, -180 ° to 180 ° | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in °: 1.35 to 180 | | Vector automatic network analyzer | | Frequency: 45 MHz to 2 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -008-CC | | Uncertainty table |
| | | Reflection coefficient: on coaxial phase (with magnitude of reflection coefficient below or equal to 0.1). 1-port coaxial device, -180 ° to 180 ° | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in º: 1.99 to 180 | | Vector automatic network analyzer | | Frequency: 2 GHz to 10 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -008-CC | | Uncertainty table |
| | | Reflection coefficient: on coaxial phase (with magnitude of reflection coefficient below or equal to 0.1). 1-port coaxial device, -180 ° to 180 ° | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in °: 3.71 to 180 | | Vector automatic network analyzer | | Frequency: 10 GHz to 18 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-001-CC, -002-CC, -008-CC | | Uncertainty table |
| | | Transmission coefficient: on coaxial magnitude. 2-port coaxial device, 0 dB to 20 dB | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in dB: 0.023 to 0.072 | | Vector automatic network analyzer | | Frequency: 2 GHz to 18 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-(001, 002, 003, 004, 007)-CC | | Uncertainty table |
| | | Transmission coefficient: on coaxial magnitude. 2-port coaxial device, 20 dB to 50 dB | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in dB: 0.035 to 0.193 | | Vector automatic network analyzer | | Frequency: 45 MHz to 1 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-(001, 002, 003, 004, 007)-CC | | Uncertainty table |
| | | Transmission coefficient: on coaxial magnitude. 2-port coaxial device, 20 dB to 50 dB | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in dB: 0.036 to 0.081 | | Vector automatic network analyzer | | Frequency: 1 GHz to 2 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-(001, 002, 003, 004, 007)-CC | | Uncertainty table |
| | | Transmission coefficient: on coaxial magnitude. 2-port coaxial device, 20 dB to 50 dB | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in dB: 0.036 to 0.152 | | Vector automatic network analyzer | | Frequency: 2 GHz to 18 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-(001, 002, 003, 004, 007)-CC | | Uncertainty table |
| | | Transmission coefficient: on coaxial magnitude. 2-port coaxial device, 50 dB to 70 dB | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in dB: 0.191 to 1.659 | | Vector automatic network analyzer | | Frequency: 45 MHz to 1 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-(001, 002, 003, 004, 007)-CC | | Uncertainty table |
| | | Transmission coefficient: on coaxial magnitude. 2-port coaxial device, 50 dB to 70 dB | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in dB: 0.080 to 0.330 | | Vector automatic network analyzer | | Frequency: 1 GHz to 2 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-(001, 002, 003, 004, 007)-CC | | Uncertainty table |
| | | Transmission coefficient: on coaxial magnitude. 2-port coaxial device, 50 dB to 70 dB | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in dB: 0.074 to 0.231 | | Vector automatic network analyzer | | Frequency: 2 GHz to 18 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-(001, 002, 003, 004, 007)-CC | | Uncertainty table |
| | | Transmission coefficient: on coaxial phase. 2-port coaxial device, -180 º to 180 º | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in º: 1.78 to 6.85 | | Vector automatic network analyzer | | Frequency: 45 MHz to 18 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Internal NMI service identifier: CENAM/410-E002-(001, 002, 003, 004, 007)-CC | | Uncertainty table |
| | | Transmission coefficient: on coaxial magnitude. 2-port coaxial device, 0 dB to 20 dB | | Absolute expanded uncertainty (k = 2, level of confidence 95.45%) in dB: 0.023 to 0.066 | | Vector automatic network analyzer | | Frequency: 45 GHz to 18 GHz | | Connector: Type N | | Approved on 09 October 2012 | | Uncertainty table |
| | | Capacitance: meters. Capacitance bridge, LCR meter (capacitance), 0.001 nF to 1000 nF | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µF/F: 0.5 to 40 | | Direct measurement | | Frequency: 1 kHz | | Voltage: 1 mV to 50 V | | Approved on 28 April 2011 | | Internal NMI service identifier: CENAM/E009-004B | | Uncertainty table |
|