Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Chemistry (277)
CMCs General Physics (249)
PHYSICS >
Force
AC voltage, current, and power
Mass, mass standards
Radio frequency measurements (52)
Sound in air (23)
Dimensional metrology (20)
Density (20)
Pressure (18)
Vibration (16)
Fluid flow (16)
Impedance up to the MHz range (16)
Torque, Viscosity, Hardness and Gravity (15)
Temperature (15)
Properties of detectors and sources (8)
Photometry (7)
CHEMICAL MATERIAL >
HNO3 in aqueous solution
organic solution, multi-component (20)
sediment (19)
soil (16)
particulates (16)
methanol (15)
CHEMICAL ANALYTE >
lead
cadmium (6)
zinc (5)
acenaphthene (5)
naphthalene (5)
nitrogen monoxide (5)
GEOGRAPHIC LOCATION
SIM (526)
Mexico (526)
Result of the search
Your query 'cenam' produced 526 results New search
[<< Prev] 27

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Photometry and Radiometry for Mexico (.PDF file)
Responsivity. Fibre optic power meter. Measurand unit, A/W or V/W or Reading/W
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 1.2
Comparison
Wavelengths: 850 nm, 1300 nm, 1550 nm
Bandwidth: 5 nm
Power level: 18 µW to 100 µW
Internal NMI service identifier: CENAM/520-D003-001, 002, 003, 004, 006
 
Responsivity, spectral, power. Broad band detector. Measurand unit, A/W, V/W, Reading/W
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 0.8 to 0.62, varies with wavelength
Monochromator plus tungsten source
Wavelength range: 350 nm to 450 nm
Bandwidth: 4 nm
Power level: 0.4 µW to 4 µW
Internal NMI service identifier: CENAM/520-D007-001
 
Responsivity, spectral, power. Broad band detector. Measurand unit, A/W, V/W, Reading/W
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 0.62 to 0.76, varies with wavelength
Monochromator plus tungsten source
Wavelength range: 450 nm to 770 nm
Bandwidth: 4 nm
Power level: 0.4 µW to 4 µW
Internal NMI service identifier: CENAM/520-D007-001
 
Responsivity, spectral, power. Broad band detector. Measurand unit, A/W, V/W, Reading/W
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 0.76 to 1.5, varies with wavelength
Monochromator plus tungsten source
Wavelength range: 770 nm to 1100 nm
Bandwidth: 4 nm
Power level: 0.4 µW to 4 µW
Internal NMI service identifier: CENAM/520-D007-001
 
Irradiance, spectral. Tungsten lamp, 7.70E-03 (W/m2)/nm to 1.09E-01 (W/m2)/nm
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 2.5
Spectroradiometer
Wavelength range: 400 nm to 795 nm
Bandwidth: 2.5 nm
Internal NMI service identifier: CENAM/520-D005-007
 
Irradiance, spectral. Tungsten lamp, 1.11E-01 (W/m2)/nm to 1.13E-01 (W/m2)/nm
Relative expanded uncertainty (k = 2, level of confidence ~95%) in %: 4
Spectroradiometer
Wavelength range: 800 nm to 995 nm
Bandwidth: 2.5 nm
Internal NMI service identifier: CENAM/520-D005-007