Refine your search |
|
CMC AREA |
|
|
|
|
PHYSICS |
|
|
|
|
CHEMICAL MATERIAL |
|
|
|
|
|
CHEMICAL ANALYTE |
|
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
|
Your query 'cenam' produced 292 results
|
New search
|
| Matrix or material |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
pH
|
Absolute
expanded uncertainty
(k = 2, 95%)
|
pH
|
Absolute
expanded uncertainty
(k = 2, 95%)
|
|
aqueous pH buffer solution
|
4.000
to 4.030
|
0.011
|
4.000
to 4.030
|
0.011
|
Mechanism(s) for measurement service delivery:
DMR 283
Temperature range for service: 15 °C to 37 °C, values given for 25°C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention (~0.010, k=2). Uncertainty convention 1. Approved on 31 March 2012.
Internal NMI service identifier: CENAM/630-Q024- 001.p4
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Electrolytic conductivity
in S/m
|
Absolute
expanded uncertainty
(k = 2, 95%)
in S/m
|
Electrolytic conductivity
in S/m
|
Absolute
expanded uncertainty
(k = 2, 95%)
in S/m
|
|
aqueous solution
|
Electrolytic conductivity |
0.00499
to 0.04991
|
0.00010
to 0.00050
|
0.0149
to 0.0152
|
0.00014
to 0.00015
|
Mechanism(s) for measurement service delivery:
DMR-297
Reference value certified at 25 °C. Uncertainty convention 1. Approved on 31 March 2012.
Internal NMI service identifier: CENAM/630-Q022-001.s
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/kg
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
fresh water
|
arsenic |
20
to 60
|
2
to 4
|
Mechanism(s) for measurement service delivery:
Value-assignment through MRTC program
Approved on 27 March 2013. Uncertainty convention 1.
Internal NMI service identifier: CENAM/620-Q008-001
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in µg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in µg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
mercury |
5.0
to 25.0
|
3.5
to 4.0
|
9
to 21
|
3.8
to 4.6
|
Mechanism(s) for measurement service delivery:
DMR-2: annual PT
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-Q008-008
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in mg/kg
|
Absolute
expanded uncertainty
(k = 2, 95%)
in mg/kg
|
Mass fraction
in mmol/l
|
Absolute
expanded uncertainty
(k = 2, 95%)
in mmol/l
|
|
human serum
|
glucose |
600
to 900
|
8
to 15
|
4.6
|
0.13
|
Mechanism(s) for measurement service delivery:
DMR 263a
Uncertainty convention 1. Approved on 12 June 2007.
Internal NMI service identifier: CENAM/630-Q023-001b
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
iron
|
chromium |
0.7
to 7
|
2.7
|
Mechanism(s) for measurement service delivery:
Analytical service, reference materials: DES-025, DES-026, DES-027, DES-028
Approved on 31 March 2012.
Internal NMI service identifier: CENAM/610-022
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount of sustance fraction
in µmol/mol
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
nitrogen
|
carbon monoxide |
10
to 80000
|
3
to 1
|
Mechanism(s) for measurement service delivery:
Program for value-assignment to gas mixture from producers (MRTC), calibration services and analytical services
Uncertainty convention 2. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/630-QS01.G001
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
o-xylene
|
o-xylene |
98.0
to 100
|
0.1
to 0.6
|
Mechanism(s) for measurement service delivery:
DMR-230
Uncertainty range convention 1. Approved on 29 April 2005.
Internal NMI service identifier: CENAM/630-C014-001
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/kg
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
polyethylene
|
lead |
300
to 600
|
2
to 3
|
Mechanism(s) for measurement service delivery:
Value-assignment through MRTC program
MRTC program: certification of a batch produced and later distributed by an external manufacturer. Uncertainty convention 1. Approved on 31 March 2012.
Internal NMI service identifier: CENAM/620-Q008-21
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount-of-substance content
in nmol/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
red wine
|
lead |
0.1
to 0.2
|
7.7
|
Mechanism(s) for measurement service delivery:
Analytical service
Internal NMI service identifier: CENAM/620-Q018-001
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount-of-substance content
in nmol/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
sediment
|
lead |
140
to 180
|
3.5
|
Mechanism(s) for measurement service delivery:
Analytical service
Internal NMI service identifier: CENAM/620-Q008-011
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in ng/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
solvent solution
|
hexachlorobenzene |
20
to 4000
|
2
to 10
|
Mechanism(s) for measurement service delivery:
Analytical services, PT 600-IL-1200
Uncertainty convention 1. Approved on 01 March 2005.
Internal NMI service identifier: CENAM/630-Q021-001
| Matrix or material |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
pH
|
Absolute
expanded uncertainty
(k = 2, 95%)
|
pH
|
Absolute
expanded uncertainty
(k = 2, 95%)
|
|
aqueous pH buffer solution
|
6.840
to 6.900
|
0.003
to 0.010
|
6.840
to 6.900
|
0.005
|
Mechanism(s) for measurement service delivery:
DMR 206
Temperature range for service: 15 °C to 37 °C, values given for 25°C. Declared uncertainties do not include the uncertainty contribution due to the Bates-Guggenheim convention (~0.010, k=2). Uncertainty convention 1. Approved on 31 March 2012.
Internal NMI service identifier: CENAM/630-Q024-001.p7
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
aqueous solution
|
chromium (VI) |
0.10
to 4.00
|
2.0
to 3.0
|
1.623
|
3.5
|
Mechanism(s) for measurement service delivery:
DMR-3: annual PT and value-assignment through MRTC program
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-C007-01
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Electrolytic conductivity
in S/m
|
Absolute
expanded uncertainty
(k = 2, 95%)
in S/m
|
Electrolytic conductivity
in S/m
|
Absolute
expanded uncertainty
(k = 2, 95%)
in S/m
|
|
aqueous solution
|
Electrolytic conductivity |
0.050000
to 0.15000
|
0.00014
to 0.00045
|
0.14020
to 0.14091
|
0.00045
|
Mechanism(s) for measurement service delivery:
DMR-148
Reference value certified at 25 °C. Uncertainty convention 1. Approved on 31 March 2012.
Internal NMI service identifier: CENAM/630-Q024-004R
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/kg
|
Absolute
expanded uncertainty
(k = 2, 95%)
in mg/kg
|
|
human serum
|
glucose |
1100
to 1400
|
12
to 24
|
Mechanism(s) for measurement service delivery:
Proficiency test and analytical service
Uncertainty convention 1. Approved on 12 June 2007.
Internal NMI service identifier: CENAM/630-Q023-002b
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in mg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
iron
|
manganese |
3
to 10
|
2.8
|
Mechanism(s) for measurement service delivery:
Analytical service, reference materials: DES-025, DES-026, DES-027, DES-028
Approved on 31 March 2012.
Internal NMI service identifier: CENAM/610-023
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in µg/kg
|
Absolute
expanded uncertainty
(k = 2, 95%)
in µg/kg
|
Mass fraction
in µg/kg
|
Absolute
expanded uncertainty
(k = 2, 95%)
in µg/kg
|
|
milk powder
|
lead |
15
to 50
|
8.48
|
21.53
|
8.48
|
Mechanism(s) for measurement service delivery:
DMR-65a
Internal NMI service identifier: CENAM/630-Q022-001
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in µg/kg
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
fresh water
|
barium |
400
to 600
|
2
to 4
|
Mechanism(s) for measurement service delivery:
Value-assignment through MRTC program
Approved on 27 March 2013. Uncertainty convention 1.
Internal NMI service identifier: CENAM/620-Q008-002
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Mass fraction
in %
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
m-xylene
|
m-xylene |
98.0
to 100.0
|
0.1
to 0.6
|
Mechanism(s) for measurement service delivery:
DMR-231
Uncertainty range convention 1. Approved on 29 April 2005.
Internal NMI service identifier: CENAM/630-C014-002
|