| | | Thailand, NIMT (National Institute of Metrology (Thailand)) | |  | Complete CMCs in Electricity and Magnetism for Thailand (.PDF file)
|  | |
| AC voltage up to 1000 V: sources. Multifunction calibrator, 40 V to 300 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 35 | | AC-DC voltage transfer | | Voltage: 40 V, 50 V, 60 V, 70 V, 100 V, 200 V, 300 V | | Frequency: 10 Hz to 20 Hz | | Internal NMI service identifier: NIMT/180 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 40 V to 300 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 27 | | AC-DC voltage transfer | | Voltage: 40 V, 50 V, 60 V, 70 V, 100 V, 200 V, 300 V | | Frequency: 30 Hz to 300 Hz | | Internal NMI service identifier: NIMT/181 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 40 V to 300 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 21 | | AC-DC voltage transfer | | Voltage: 40 V, 50 V, 60 V, 70 V, 100 V, 200 V, 300 V | | Frequency: 400 Hz to 30 kHz | | Internal NMI service identifier: NIMT/182 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 40 V to 300 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 26 | | AC-DC voltage transfer | | Voltage: 40 V, 50 V, 60 V, 70 V, 100 V, 200 V, 300 V | | Frequency: 50 kHz to 70 kHz | | Internal NMI service identifier: NIMT/183 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 40 V to 300 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 31 | | AC-DC voltage transfer | | Voltage: 40 V, 50 V, 60 V, 70 V, 100 V, 200 V, 300 V | | Frequency: 100 kHz | | Internal NMI service identifier: NIMT/184 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 500 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 44 | | AC-DC voltage transfer | | Frequency: 10 Hz to 20 Hz | | Internal NMI service identifier: NIMT/185 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 500 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 35 | | AC-DC voltage transfer | | Frequency: 30 Hz to 300 Hz | | Internal NMI service identifier: NIMT/186 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 500 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 27 | | AC-DC voltage transfer | | Frequency: 400 Hz to 30 kHz | | Internal NMI service identifier: NIMT/187 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 500 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 35 | | AC-DC voltage transfer | | Frequency: 50 kHz to 70 kHz | | Internal NMI service identifier: NIMT/188 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 500 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 44 | | AC-DC voltage transfer | | Frequency: 100 kHz | | Internal NMI service identifier: NIMT/189 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 1000 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 54 | | AC-DC voltage transfer | | Frequency: 10 Hz to 20 Hz | | Internal NMI service identifier: NIMT/190 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 1000 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 47 | | AC-DC voltage transfer | | Frequency: 30 Hz to 300 Hz | | Internal NMI service identifier: NIMT/191 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 1000 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 31 | | AC-DC voltage transfer | | Frequency: 400 Hz to 30 kHz | | Internal NMI service identifier: NIMT/192 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 1000 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 63 | | AC-DC voltage transfer | | Frequency: 50 kHz to 70 kHz | | Internal NMI service identifier: NIMT/193 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 1000 V | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 82 | | AC-DC voltage transfer | | Frequency: 100 kHz | | Internal NMI service identifier: NIMT/194 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 10 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 110 | | AC-DC voltage transfer | | Frequency: 10 Hz to 20 Hz | | Internal NMI service identifier: NIMT/131 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 10 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 93 | | AC-DC voltage transfer | | Frequency: 30 Hz to 300 Hz | | Internal NMI service identifier: NIMT/132 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 10 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 93 | | AC-DC voltage transfer | | Frequency: 400 Hz to 30 kHz | | Internal NMI service identifier: NIMT/133 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 10 mV | | Relative expanded uncertainty (k = 3, level of confidence 95%) in µV/V: 93 | | AC-DC voltage transfer | | Frequency: 50 kHz to 70 kHz | | Internal NMI service identifier: NIMT/134 |
| | | AC voltage up to 1000 V: sources. Multifunction calibrator, 10 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 110 | | AC-DC voltage transfer | | Frequency: 100 kHz | | Internal NMI service identifier: NIMT/135 |
|