| | | Thailand, NIMT (National Institute of Metrology (Thailand)) | |  | Complete CMCs in Electricity and Magnetism for Thailand (.PDF file)
|  | |
| AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 60 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 150 | | AC-DC voltage transfer | | Frequency: 700 kHz to 1 MHz | | Internal NMI service identifier: NIMT/80 |
| | | AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 100 mV to 200 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 37 | | AC-DC voltage transfer | | Voltage: 100 mV, 200 mV | | Frequency: 10 Hz to 20 Hz | | Internal NMI service identifier: NIMT/81 |
| | | AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 100 mV to 200 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 24 | | AC-DC voltage transfer | | Voltage: 100 mV, 200 mV | | Frequency: 30 Hz to 300 Hz | | Internal NMI service identifier: NIMT/82 |
| | | AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 100 mV to 200 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 24 | | AC-DC voltage transfer | | Voltage: 100 mV, 200 mV | | Frequency: 400 Hz to 30 kHz | | Internal NMI service identifier: NIMT/83 |
| | | AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 100 mV to 200 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 24 | | AC-DC voltage transfer | | Voltage: 100 mV, 200 mV | | Frequency: 50 kHz to 70 kHz | | Internal NMI service identifier: NIMT/84 |
| | | AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 100 mV to 200 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 32 | | AC-DC voltage transfer | | Voltage: 100 mV, 200 mV | | Frequency: 100 kHz | | Internal NMI service identifier: NIMT/85 |
| | | AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 100 mV to 200 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 76 | | AC-DC voltage transfer | | Voltage: 100 mV, 200 mV | | Frequency: 200 kHz to 500 kHz | | Internal NMI service identifier: NIMT/86 |
| | | AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 100 mV to 200 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 120 | | AC-DC voltage transfer | | Voltage: 100 mV, 200 mV | | Frequency: 700 kHz to 1 MHz | | Internal NMI service identifier: NIMT/87 |
| | | AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 300 mV to 500 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 16 | | AC-DC voltage transfer | | Voltage: 300 mV, 500 mV | | Frequency: 10 Hz to 20 Hz | | Internal NMI service identifier: NIMT/88 |
| | | AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 300 mV to 500 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 16 | | AC-DC voltage transfer | | Voltage: 300 mV, 500 mV | | Frequency: 30 Hz to 300 Hz | | Internal NMI service identifier: NIMT/89 |
| | | AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 300 mV to 500 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 13 | | AC-DC voltage transfer | | Voltage: 300 mV, 500 mV | | Frequency: 400 Hz to 30 kHz | | Internal NMI service identifier: NIMT/90 |
| | | AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 300 mV to 500 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 13 | | AC-DC voltage transfer | | Voltage: 300 mV, 500 mV | | Frequency: 50 kHz to 70 kHz | | Internal NMI service identifier: NIMT/91 |
| | | AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 300 mV to 500 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 14 | | AC-DC voltage transfer | | Voltage: 300 mV, 500 mV | | Frequency: 100 kHz | | Internal NMI service identifier: NIMT/92 |
| | | AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 300 mV to 500 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 21 | | AC-DC voltage transfer | | Voltage: 300 mV, 500 mV | | Frequency: 200 kHz to 500 kHz | | Internal NMI service identifier: NIMT/93 |
| | | AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 300 mV to 500 mV | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 32 | | AC-DC voltage transfer | | Voltage: 300 mV, 500 mV | | Frequency: 700 kHz to 1 MHz | | Internal NMI service identifier: NIMT/94 |
|