Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (35)
PHYSICS
AC voltage, current, and power (35)
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V) (35)
GEOGRAPHIC LOCATION
APMP (35)
Thailand (35)
Result of the search
Your query 'NIMT' produced 35 results New search
[Prev] 2

 
Thailand, NIMT (National Institute of Metrology (Thailand))
Complete CMCs in Electricity and Magnetism for Thailand (.PDF file)
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 60 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 150
AC-DC voltage transfer
Frequency: 700 kHz to 1 MHz
Internal NMI service identifier: NIMT/80
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 100 mV to 200 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 37
AC-DC voltage transfer
Voltage: 100 mV, 200 mV
Frequency: 10 Hz to 20 Hz
Internal NMI service identifier: NIMT/81
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 100 mV to 200 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 24
AC-DC voltage transfer
Voltage: 100 mV, 200 mV
Frequency: 30 Hz to 300 Hz
Internal NMI service identifier: NIMT/82
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 100 mV to 200 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 24
AC-DC voltage transfer
Voltage: 100 mV, 200 mV
Frequency: 400 Hz to 30 kHz
Internal NMI service identifier: NIMT/83
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 100 mV to 200 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 24
AC-DC voltage transfer
Voltage: 100 mV, 200 mV
Frequency: 50 kHz to 70 kHz
Internal NMI service identifier: NIMT/84
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 100 mV to 200 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 32
AC-DC voltage transfer
Voltage: 100 mV, 200 mV
Frequency: 100 kHz
Internal NMI service identifier: NIMT/85
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 100 mV to 200 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 76
AC-DC voltage transfer
Voltage: 100 mV, 200 mV
Frequency: 200 kHz to 500 kHz
Internal NMI service identifier: NIMT/86
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 100 mV to 200 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 120
AC-DC voltage transfer
Voltage: 100 mV, 200 mV
Frequency: 700 kHz to 1 MHz
Internal NMI service identifier: NIMT/87
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 300 mV to 500 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 16
AC-DC voltage transfer
Voltage: 300 mV, 500 mV
Frequency: 10 Hz to 20 Hz
Internal NMI service identifier: NIMT/88
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 300 mV to 500 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 16
AC-DC voltage transfer
Voltage: 300 mV, 500 mV
Frequency: 30 Hz to 300 Hz
Internal NMI service identifier: NIMT/89
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 300 mV to 500 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 13
AC-DC voltage transfer
Voltage: 300 mV, 500 mV
Frequency: 400 Hz to 30 kHz
Internal NMI service identifier: NIMT/90
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 300 mV to 500 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 13
AC-DC voltage transfer
Voltage: 300 mV, 500 mV
Frequency: 50 kHz to 70 kHz
Internal NMI service identifier: NIMT/91
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 300 mV to 500 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 14
AC-DC voltage transfer
Voltage: 300 mV, 500 mV
Frequency: 100 kHz
Internal NMI service identifier: NIMT/92
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 300 mV to 500 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 21
AC-DC voltage transfer
Voltage: 300 mV, 500 mV
Frequency: 200 kHz to 500 kHz
Internal NMI service identifier: NIMT/93
 
AC-DC voltage transfer: AC-DC transfer difference at low voltages (equal or below 0.5 V). Thermal converters, AC-DC transfer standard, 300 mV to 500 mV
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 32
AC-DC voltage transfer
Voltage: 300 mV, 500 mV
Frequency: 700 kHz to 1 MHz
Internal NMI service identifier: NIMT/94