Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs Chemistry (7)
PHYSICS
Vibration
Properties of detectors and sources
CHEMICAL MATERIAL >
HNO3 in aqueous solution
copper alloy (1)
fresh water (1)
polyethylene (1)
red wine (1)
sediment (1)
CHEMICAL ANALYTE
zinc
phenanthrene
lead (7)
GEOGRAPHIC LOCATION
SIM (7)
Mexico (7)
Result of the search
Your query 'cenam' produced 7 results New search

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Advanced materials for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95%) in %
polyethylene lead 300 to 600 2 to 3
Mechanism(s) for measurement service delivery: Value-assignment through MRTC program
MRTC program: certification of a batch produced and later distributed by an external manufacturer.
Uncertainty convention 1.
Approved on 31 March 2012.
Internal NMI service identifier: CENAM/620-Q008-21

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Food for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance content in nmol/g Relative expanded uncertainty
(k = 2, 95%) in %
red wine lead 0.1 to 0.2 7.7
Mechanism(s) for measurement service delivery: Analytical service
Internal NMI service identifier: CENAM/620-Q018-001

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Sediments, soils, ores, and particulates for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Amount-of-substance content in nmol/g Relative expanded uncertainty
(k = 2, 95%) in %
sediment lead 140 to 180 3.5
Mechanism(s) for measurement service delivery: Analytical service
Internal NMI service identifier: CENAM/620-Q008-011

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Food for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability Range of certified values in reference materials
Mass fraction in µg/kg Absolute expanded uncertainty
(k = 2, 95%) in µg/kg
Mass fraction in µg/kg Absolute expanded uncertainty
(k = 2, 95%) in µg/kg
milk powder lead 15 to 50 8.48 21.53 8.48
Mechanism(s) for measurement service delivery: DMR-65a
Internal NMI service identifier: CENAM/630-Q022-001

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Water for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in µg/kg Relative expanded uncertainty
(k = 2, 95%) in %
fresh water lead 5 to 30 1 to 3
Mechanism(s) for measurement service delivery: Value-assignment through MRTC program
Approved on 27 March 2013.
Uncertainty convention 1.
Internal NMI service identifier: CENAM/620-Q008-007

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Metals and metal alloys for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in mg/kg Relative expanded uncertainty
(k = 2, 95%) in %
nickel lead 0.3 to 2 45 to 30
Mechanism(s) for measurement service delivery: Value-assignment through MRTC program
Approved on 31 March 2012.
Uncertainty convention 2.
Internal NMI service identifier: CENAM/620-Q018-3

Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Chemistry for Metals and metal alloys for Mexico (.PDF file)
Matrix or material Analyte or component Dissemination range of measurement capability
Mass fraction in % Relative expanded uncertainty
(k = 2, 95%) in %
copper alloy lead 1 to 2.5 4 to 3
Mechanism(s) for measurement service delivery: Value-assignment through MRTC program
Approved on 19 July 2010.
Uncertainty convention 2.
Internal NMI service identifier: CENAM/620-C002-20