Your query 'cenam' produced 289 results
|
New search
|
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in µg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
soil
|
benzo (b) fluoranthene |
1
to 15
|
4
to 6
|
1
to 4
|
4
to 6
|
Mechanism(s) for measurement service delivery:
DMR-199b, DMR 200b, DMR 293a, DMR 294a
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-031
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in µg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
soil
|
benzo (k) fluoranthene |
0.2
to 15
|
4
to 10
|
0.2
to 3
|
5
to 10
|
Mechanism(s) for measurement service delivery:
DMR-199b, DMR 200b, DMR 293a
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-032
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in µg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
soil
|
indeno (1,2,3-c,d) pyrene |
1
to 15
|
4
to 10
|
1
to 4
|
5
to 10
|
Mechanism(s) for measurement service delivery:
DMR-199b, DMR 200b, DMR 294a
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-033
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in µg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in µg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
soil
|
dibenz (a,h) anthracene |
0.1
to 15
|
4
to 9
|
0.1
to 1
|
6
to 9
|
Mechanism(s) for measurement service delivery:
DMR-199b, DMR 200b, DMR 293a
Uncertainty range convention 1. Approved on 23 November 2009.
Internal NMI service identifier: CENAM/630-Q023-034
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
|
Amount-of-substance content
in nmol/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
|
sediment
|
cadmium |
5
to 9
|
3
|
Mechanism(s) for measurement service delivery:
Value-assignment through CENAM Traceable Reference Materials (MRTC)
Approved on 19 July 2010.
Internal NMI service identifier: CENAM/620-Q008-010R
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in mg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in mg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in mg/g
|
|
feldspar
|
total silicon as silicon oxide |
500
to 800
|
1
to 2
|
699
|
7.1
|
Mechanism(s) for measurement service delivery:
CRM DMR-422a, analytical services
Approved on 31 March 2012. Uncertainty convention 1.
Internal NMI service identifier: CENAM/610-034
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in mg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in mg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in mg/g
|
|
feldspar
|
total aluminum as aluminum oxide |
100
to 300
|
2
to 1.6
|
174
|
2.8
|
Mechanism(s) for measurement service delivery:
CRM DMR-422a, analytical services
Approved on 31 March 2012. Uncertainty convention 2.
Internal NMI service identifier: CENAM/610-035
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in mg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in mg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in mg/g
|
|
feldspar
|
total calcium as calcium oxide |
4
to 40
|
4
to 8
|
4
|
0.2
|
Mechanism(s) for measurement service delivery:
CRM DMR-422a, analytical services
Approved on 31 March 2012. Uncertainty convention 1.
Internal NMI service identifier: CENAM/610-036
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass fraction
in mg/g
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass fraction
in mg/g
|
Absolute
expanded uncertainty
(k = 2, 95%)
in mg/g
|
|
feldspar
|
total potassium as potassium oxide |
40
to 150
|
4
|
56.5
|
2.3
|
Mechanism(s) for measurement service delivery:
CRM DMR-422a, analytical services
Approved on 31 March 2012.
Internal NMI service identifier: CENAM/610-037
|