Home    Key and supplementary comparisons    Calibration and Measurement Capabilities - CMCs
The BIPM key comparison database
Refine your search
CMC AREA
CMCs General Physics (3)
PHYSICS
Vibration
DC voltage, current, and resistance (3)
DC voltage sources: single values (3)
CHEMICAL ANALYTE
zinc
GEOGRAPHIC LOCATION
SIM (3)
Mexico (3)
Result of the search
Your query 'cenam' produced 3 results New search

 
Mexico, CENAM (Centro Nacional de Metrologia)
Complete CMCs in Electricity and Magnetism for Mexico (.PDF file)
DC voltage sources: single values. Solid state voltage standard, 1 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 0.3
Ratio technique from 1.018 V to 1 V via a DVM
Room temperature: 23 °C
Ambient pressure: 81 kPa
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E011-003-01
 
DC voltage sources: single values. Solid state voltage standard, 1.018 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 0.3
Differential measurement using a redundant design
Room temperature: 23 °C
Ambient pressure: 81 kPa
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E011-003-02
 
DC voltage sources: single values. Solid state voltage standard, 10 V
Relative expanded uncertainty (k = 2, level of confidence 95%) in µV/V: 0.3
Ratio technique from 1.018 V to 10 V via a DVM and a resistive divider
Room temperature: 23 °C
Ambient pressure: 81 kPa
Approved on 28 April 2011
Internal NMI service identifier: CENAM/E011-003-03