Refine your search |
|
CMC AREA |
|
|
|
|
PHYSICS |
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
|
Your query 'Costa Rica' produced 6 results
|
New search
|
| | | Costa Rica, ICE-LMVE (Instituto Costarricense de Electricidad, Laboratorio Metrológico de Variables Eléctricas) | |  | Complete CMCs in Electricity and Magnetism for Costa Rica (.PDF file)
|  | |
DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, > 1 M to 10 M | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 49 to 119 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21301 |
| | DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, 10 M to 100 M | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 398 to 468 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21302 |
| | DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, 20 M to 200 M | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 173 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21303 |
| | DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, 0.2 G to 2 G | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 231 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21304 |
| | DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, 2 G to 20 G | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 693 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21305 |
| | DC resistance, DC resistance standards and sources, high values. Fixed resistor, resistance box, 20 G to 200 G | | Relative expanded uncertainty (k = 2, level of confidence 95%) in µ / : 924 | | Direct comparison | | Approved on 23 March 2010 | | Internal NMI service identifier: ICE-LMVE/21306 |
|