Refine your search |
|
CMC AREA |
|
|
|
|
PHYSICS |
|
|
|
|
CHEMICAL MATERIAL |
|
|
|
|
CHEMICAL ANALYTE |
|
|
|
|
GEOGRAPHIC LOCATION |
|
|
|
|
|
 |
Result of the search |
|
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in µg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in µg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
mercury |
5.0
to 25.0
|
3.5
to 4.0
|
9
to 21
|
3.8
to 4.6
|
Mechanism(s) for measurement service delivery:
DMR-2: annual PT
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-Q008-008
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
aluminum |
7.0
to 20.0
|
0.4
to 3.5
|
8.0
to 16.0
|
3.3
|
Mechanism(s) for measurement service delivery:
DMR-8: annual PT
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-C002-008
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
cadmium |
0.5
to 2.0
|
0.4
to 2.8
|
0.5
to 2.0
|
0.45
to 4.0
|
Mechanism(s) for measurement service delivery:
DMR-8, DMR-342, DMR-400, DMR-171: annual PT and value-assignment through MRTC program
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-C002-009
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
copper |
0.5
to 4.0
|
0.6
to 4.0
|
0.6
to 3.8
|
3.6
|
Mechanism(s) for measurement service delivery:
DMR-8: annual PT
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-C002-010
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
chromium |
1.0
to 5.0
|
0.7
to 4.7
|
1.5
to 4.0
|
3.8
|
Mechanism(s) for measurement service delivery:
DMR-8: annual PT
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-C002-011
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
nickel |
0.5
to 2.0
|
0.6
to 2.2
|
0.6
to 2.0
|
4.2
|
Mechanism(s) for measurement service delivery:
DMR-8: annual PT
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-C002-012
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
lead |
1.0
to 15.0
|
0.8
to 3.5
|
1.0
to 11.0
|
3.5
|
Mechanism(s) for measurement service delivery:
DMR-8: annual PT
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-C002-013
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
arsenic |
0.10
to 1.00
|
1.8
to 3.0
|
0.100
to 1.000
|
2.0
to 3.5
|
Mechanism(s) for measurement service delivery:
DMR-8, DMR-341, DMR-400, DMR-171: annual PT
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-Q008-009
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
silver |
0.50
to 3.50
|
3.0
to 4.0
|
0.5
to 2.5
|
3.5
to 4.5
|
Mechanism(s) for measurement service delivery:
DMR-11: annual PT
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-C002-015
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2.78, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
copper |
950
to 1050
|
0.15
to 0.5
|
999.1
|
0.2
to 0.6
|
Mechanism(s) for measurement service delivery:
DMR 17, CAL-620-51
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-Q014-001
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
nickel |
950
to 1050
|
0.40
to 0.6
|
950
to 1050
|
0.5
to 0.7
|
Mechanism(s) for measurement service delivery:
DMR-40, DMR-465
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-Q014-002
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
chromium |
950
to 1050
|
0.40
to 0.6
|
950
to 1050
|
0.5
to 0.7
|
Mechanism(s) for measurement service delivery:
DMR-94, DMR-440
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-C002-001
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
calcium |
950
to 1050
|
0.15
to 0.40
|
950
to 1050
|
0.2
to 0.5
|
Mechanism(s) for measurement service delivery:
DMR-55
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-Q014-003
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
sodium |
950
to 1050
|
0.30
to 0.40
|
950
to 1050
|
0.3
to 0.5
|
Mechanism(s) for measurement service delivery:
DMR-56
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-Q013-001
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
magnesium |
950
to 1050
|
0.30
to 0.40
|
950
to 1050
|
0.3
to 0.5
|
Mechanism(s) for measurement service delivery:
DMR-62
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-C002-003
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
lead |
950
to 1050
|
0.15
to 0.40
|
950
to 1050
|
0.2
to 0.5
|
Mechanism(s) for measurement service delivery:
DMR-63, DMR-463
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-C002-004
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
aluminum |
950
to 1050
|
0.30
to 0.40
|
950
to 1050
|
0.3
to 0.5
|
Mechanism(s) for measurement service delivery:
DMR-78
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-C002-005
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
cadmium |
950
to 1050
|
0.30
to 0.40
|
950
to 1050
|
0.2
to 0.5
|
Mechanism(s) for measurement service delivery:
DMR-85, DMR-461
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-C002-006
| Matrix or material |
Analyte or component |
Dissemination range of measurement capability |
Range of certified values in reference materials |
|
Mass concentration
in mg/L
|
Relative
expanded uncertainty
(k = 2, 95%)
in %
|
Mass concentration
in mg/L
|
Absolute
expanded uncertainty
(k = 2, 95%)
in %
|
|
HNO3 in aqueous solution
|
iron |
950
to 1050
|
0.40
to 0.60
|
950
to 1050
|
0.5
to 0.7
|
Mechanism(s) for measurement service delivery:
DMR-86, CAL-620-67
Uncertainty convention 1. Approved on 27 March 2013.
Internal NMI service identifier: CENAM/620-C002-007
|